Skip to main content

Improved Motion Correction of fMRI Time-Series Corrupted with Major Head Movement Using Extended Motion-Corrected Independent Component Analysis

  • Conference paper
Computer Vision for Biomedical Image Applications (CVBIA 2005)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 3765))

  • 1756 Accesses

Abstract

An extension of previously-described Motion-Corrected Independent Component Analysis (MCICA) for improved correction of significant patient head motion in fMRI data is proposed. For fMRI time-points corrupted with relatively large motion, i.e. on the order of half a voxel, only partial images subject to minimal interpolation artifact are initially used in MCICA, allowing for an accurate estimation of the activation weights of the underlying ICA components. The remaining voxels that are irretrievably corrupted with gross motion in the motion-corrupted time-points are treated as missing data, so the final component maps of the ICA components are estimated from an optimally motionless reference ensemble. Interpolation artifact therefore is minimized in the final registered image, which can be mathematically expressed as a weighted combination of the extended reference ensemble. Experiments demonstrate that the proposed method was robust to the presence of simulated activation and the number of reference images used. While the previous version of MCICA already achieved noticeably decreased registration error than SPM and AIR, the proposed method further reduced the error by thirty percent when correcting simulated gross movements applied on real fMRI time-points. With a real fMRI time-series acquired during a motor-task, further increased mutual information and more clustered activation in the primary and supplementary motor areas were observed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Hajnal, J.V., Myers, R., Oatridge, A., Schwieso, J.E., Young, I.R., Bydder, G.M.: Artifacts due to Stimulus Correlated Motion in Functional Imaging of The Brain. Magnetic Resonance in Medicine 31, 283–291 (1994)

    Article  Google Scholar 

  2. Liao, R., Krolik, J.L., McKeown, M.J.: An Information-Theoretic Criterion for Intrasubject Alignment of FMRI Time-Series: Motion Corrected Independent Component Analysis. IEEE Transactions on Medical Imaging 24, 29–44 (2005)

    Article  Google Scholar 

  3. Woods, R.P., Grafton, S.T., Holmes, C.J., Cherry, S.R., Mazziotta, J.C.: Automate Image Registration: I. General Methods and Intrasubject, Intramodality Validation. Journal of Computer Assisted Tomography 22, 139–152 (1998)

    Article  Google Scholar 

  4. Friston, K.J., Holmes, A.P., Worsley, K.J., Poline, J.P., Frith, C.D., Frackowiak, R.S.J.: Statistical Parametric Maps in Functional Imaging: A General Linear Approach. Human Brain Mapping 2, 189–210 (1995)

    Article  Google Scholar 

  5. Bell, A.J., Sejnowski, T.J.: An Information-Maximization Approach to Blind Separation and Blind Deconvolution. Neural Computation 7, 1004–1034 (1995)

    Article  Google Scholar 

  6. Liao, R., McKeown, M.J., Krolik, J.L.: Isolation and Minimization of Effects of Motion on fMRI Data Using Multiple Reference Images. In: The Second IEEE International Symposium on Biomedical Imaging, pp. 916–919 (2004)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2005 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Liao, R., McKeown, M., Krolik, J. (2005). Improved Motion Correction of fMRI Time-Series Corrupted with Major Head Movement Using Extended Motion-Corrected Independent Component Analysis. In: Liu, Y., Jiang, T., Zhang, C. (eds) Computer Vision for Biomedical Image Applications. CVBIA 2005. Lecture Notes in Computer Science, vol 3765. Springer, Berlin, Heidelberg. https://doi.org/10.1007/11569541_35

Download citation

  • DOI: https://doi.org/10.1007/11569541_35

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-29411-5

  • Online ISBN: 978-3-540-32125-5

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics