Abstract
The volume of dense breast tissue can be calculated from an x-ray mammogram by imaging a calibrated step-wedge alongside the breast and determining the compressed breast thickness. Previously published work used a step-wedge made of PTFE with a maximum height of 35mm, length 175mm and width 15mm. Although fulfilling all theoretical requirements, it can be difficult to find space on the film for a large step-wedge when examining bigger breasts. Furthermore, the step-wedge is lead-lined, making it heavy and difficult to attach to the bucky. A more compact aluminium step-wedge has been designed to overcome these limitations, and experiments have been carried out on a prototype to evaluate its performance. Initial results show that the maximum and minimum heights of the prototype step-wedge are inadequate to sufficiently cover the range of optical densities within a breast image at the higher and lower exposures required for 6cm and 2cm Perspex (>200mAs and <40mAs respectively). However, the step increment appears to be satisfactory. Analysis of the mean pixel value and standard deviation within Regions of Interest of varying size and position indicates an optimum step length of 3mm. A new step-wedge has been constructed with an improved specification informed by the evaluation of the prototype.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Wolfe, J.N.: Breast patterns as an index of risk for developing breast cancer. Am. J. Roentgenol. 126(6), 1130–1137 (1976)
Boyd, N.F., O’Sullivan, B., Campbell, J.E., Fishell, E., Simor, I., Cooke, G., Germanson, T.: Mammographic signs as risk factors for breast cancer. Br. J. Cancer 45(2), 185–193 (1982)
Boyd, N.F., Byng, J.W., Jong, R.A., Fishell, E.K., Little, L.E., Miller, A.B., Lockwood, G.A., Tritchler, D.L., Yaffe, M.J.: Quantitative classification of mammographic densities and breast cancer risk: results from the Canadian National Breast Screening Study. J. Natl. Cancer Inst. 87(9), 670–675 (1995)
Byng, J.W., Yaffe, M.J., Lockwood, G.A., Little, L.E., Tritchler, D.L., Boyd, N.F.: Automated analysis of mammographic densities and breast carcinoma risk. Cancer 80(1), 66–74 (1997)
Byng, J.W., Boyd, N.F., Fishell, E., Jong, R.A., Yaffe, M.J.: Automated analysis of mammographic densities. Phys. Med. Biol. 41(5), 909–923 (1996)
Byng, J.W., Boyd, N.F., Fishell, E., Jong, R.A., Yaffe, M.J.: The quantitative analysis of mammographic densities. Phys. Med. Biol. 39(10), 1629–1638 (1994)
Zhou, C., Chan, H.P., Petrick, N., Helvie, M.A., Goodsitt, M.M., Sahiner, B., Hadjiiski, L.M.: Computerized image analysis: estimation of breast density on mammograms. Med. Phys. 28(6), 1056–1069 (2001)
Pawluczyk, O., Augustine, B.J., Yaffe, M.J., Rico, D., Yang, J., Mawdsley, G.E., Boyd, N.F.: A volumetric method for estimation of breast density on digitized screen-film mammograms. Med. Phys. 30(3), 352–364 (2003)
Highnam, R.P., Brady, M., Shepstone, B.J.: A representation for mammographic image processing. Med. Image. Anal. 1(1), 1–18 (1996)
Highnam, R.P., Brady, M., Shepstone, B.J.: Mammographic image analysis. Eur. J. Radiol. 24(1), 20–32 (1997)
Patel, H.G., Astley, S.M., Hufton, A.P., Harvie, M., Hagan, K., Marchant, T.E., Hillier, V., Howell, A.: Automated breast tissue measurement of women at increased risk of breast cancer. In: Pisano, E. (ed.) Proceedings of the 7th International Workshop on Digital Mammography, Durham, North Carolina, June 18-21, 2004 (2006)
Hufton, A.P., Astley, S.M., Marchant, T.E., Patel, H.G.: A method for the quantification of dense breast tissue from digitised mammograms. In: Pisano, E. (ed.) Proceedings of the 7th International Workshop on Digital Mammography, Manchester, England, June 18-21 (2006)
Smith, J.H., Astley, S.M., Graham, J., Hufton, A.P.: The calibration of grey levels in mammograms. In: Doi, K., Giger, M.L., Nishikawa, R.M., Schmidt, R.A. (eds.) 3rd International Workshop on Digital Mammography, Chicago, published in, Digital Mammography 1996, pp. 195–200. Elsevier, New York (1996)
Berks, M., Diffey, J., Hufton, A., Astley, S.: Feasibility and acceptability of stepwedge-based density measurement. In: Proceedings of the 8th International Workshop on Digital Mammography, Manchester, England, June 18-21 (2006)
Reilly, A.J., Sutton, D.: Report 78 Spectrum Processor. Institute of Physics and Engineering in Medicine (1997)
http://www.physics.nist.gov/PhysRefData/XrayMassCoef/cover.html
Kodak.: Kodak LS85 film digitizer product specifications. Eastman Kodak Company, Rochester, NY. Cat. No. 165 2908 (2001)
Marchant, T.E.: Calibrating densities in mammography. MSc thesis, Department of Imaging Science and Biomedical Engineering, University of Manchester, UK (2002)
ICRU Report 44.: Tissue Substitutes in Radiation Dosimetry and Measurement. International Commission on Radiation Units and Measurements (1989)
Kaufhold, J., Thomas, J.A., Eberhard, J.W., Galbo, C.E., Gonzalez Trotter, D.E.: A calibration approach to glandular tissue composition estimation in digital mammography. Med. Phys. 29(8), 1867–1880 (2002)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2006 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Diffey, J., Hufton, A., Astley, S. (2006). A New Step-Wedge for the Volumetric Measurement of Mammographic Density. In: Astley, S.M., Brady, M., Rose, C., Zwiggelaar, R. (eds) Digital Mammography. IWDM 2006. Lecture Notes in Computer Science, vol 4046. Springer, Berlin, Heidelberg. https://doi.org/10.1007/11783237_1
Download citation
DOI: https://doi.org/10.1007/11783237_1
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-35625-7
Online ISBN: 978-3-540-35627-1
eBook Packages: Computer ScienceComputer Science (R0)