Skip to main content

Reduction of Ring Artifacts in High Resolution X-Ray Microtomography Images

  • Conference paper

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 4174))

Abstract

Ring artifacts can occur in reconstructed images from X-ray microtomography as full or partial circles centred on the rotation axis. In this paper, a 2D method is proposed that reduces these ring artifacts in the reconstructed images. The method consists of two main parts. First, the artifacts are localised in the image using local orientation estimation of the image structures and filtering to find ring patterns in the orientation information. Second, the map of the located artifacts is used to calculate a correction image using normalised convolution. The method is evaluated on 2D images from volume data of paper fibre imaged at the European Synchrotron Radiation Facility (ESRF) with high resolution X-ray microtomography. The results show that the proposed method reduces the artifacts and restores the pixel values for all types of partial and complete ring artifacts where the signal is not completely saturated.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Vidal, F.P., Letang, J.M., Peix, G., Cloetens, P.: Investigation of artefact sources in synchrotron microtomography via virtual X-ray imaging. Nuclear Instruments and Methods in Physics Research B 234, 333–348 (2005)

    Article  Google Scholar 

  2. Antoine, C., Nygård, P., Gregersen, Ø.W., Holmstad, R., Weitkamp, T., Rau, C.: 3D images of paper obtained by phase-contrast X-ray microtomography: image quality and binarisation. Nuclear Instruments and Methods in Physics Research A 490, 392–402 (2002)

    Article  Google Scholar 

  3. Cloetens, P.: Contribution to Phase Contrast Imaging, Reconstruction and Tomography with Hard Synchrotron Radiation – Principles, Implementation and Applications. PhD thesis, Vrije Universiteit Brussel (1999)

    Google Scholar 

  4. Jenneson, P., Gilboy, W., Morton, E.J., Gregory, P.J.: An X-ray micro-tomography system optimised for the low-dose study of living organisms. Applied Radiation and Isotopes 58, 177–181 (2003)

    Article  Google Scholar 

  5. Davis, G.R., Elliott, J.C.: X-ray microtomography scanner using time-delay integration for elimination of ring artefacts in the reconstructed image. Nuclear Instruments and Methods in Physics Research A 394, 157–162 (1997)

    Article  Google Scholar 

  6. Raven, C.: Numerical removal of ring artifacts in microtomography. Review of Scientific instruments 69(8), 2978–2980 (1998)

    Article  Google Scholar 

  7. Tang, X., Ning, R., Yu, R., Conover, D.: Cone beam volume CT image artifacts caused by defective cells in X-ray flat panel imagers and the artifact removal using a wavelet-analysis-based algorithm. Medical Physics 28(5), 812–825 (2001)

    Article  Google Scholar 

  8. Sijbers, J., Postnov, A.: Reduction of ring artefacts in high resolution micro-CT reconstructions. Physics in Medicine and Biology 49(14), N247–N253 (2004)

    Article  Google Scholar 

  9. Granlund, G.H., Knutsson, H.: Signal Processing for Computer Vision. Kluwer Academic Publishers, Dordrecht (1995)

    Google Scholar 

  10. Knutsson, H., Westin, C.F.: Normalized and differential convolution: Methods for interpolation and filtering of incomplete and uncertain data. In: Proceedings of IEEE Computer Society Conference on Computer Vision and Pattern Recognition, pp. 515–523 (1993)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2006 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Axelsson, M., Svensson, S., Borgefors, G. (2006). Reduction of Ring Artifacts in High Resolution X-Ray Microtomography Images. In: Franke, K., Müller, KR., Nickolay, B., Schäfer, R. (eds) Pattern Recognition. DAGM 2006. Lecture Notes in Computer Science, vol 4174. Springer, Berlin, Heidelberg. https://doi.org/10.1007/11861898_7

Download citation

  • DOI: https://doi.org/10.1007/11861898_7

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-44412-1

  • Online ISBN: 978-3-540-44414-5

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics