Abstract
The amount of data contained in electroencephalogram (EEG) recordings is quite massive and this places constraints on bandwidth and storage. The requirement of online transmission of data needs a scheme that allows higher performance with lower computation. Single channel algorithms, when applied on multichannel EEG data fail to meet this requirement. While there have been many methods proposed for multichannel ECG compression, not much work appears to have been done in the area of multichannel EEG compression. In this paper, we present an EEG compression algorithm based on a multichannel model, which gives higher performance compared to other algorithms. Simulations have been performed on both normal and pathological EEG data and it is observed that a high compression ratio with very large SNR is obtained in both cases. The reconstructed signals are found to match the original signals very closely, thus confirming that diagnostic information is being preserved during transmission.
Keywords
- Discrete Cosine Transform
- High Compression Ratio
- Neural Network Predictor
- Single Channel Method
- Single Channel Algorithm
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
EEG data compression techniques, Antoniol, G.; Tonella, P., IEEE Transactions on Biomedical Engineering, Volume: 44 Issue: 2, Feb. 1997, Page(s): 105–114
Recurrent neural network predictors for EEG signal compression, Bartolini, F.; Cappellini, V.; Nerozzi, S.; Mecocci, A., International Conference on Acoustics, Speech, and Signal Processing, 1995. ICASSP-95 Volume: 5, 1995 Page(s): 3395–3398.
Lossless and near-lossless compression of EEG signals, Cinkler, J.; Kong, X., Memon, N.,Conference Record of the Thirty-First Asilomar Conference on Signals, Systems & Computers.Volume: 2, 1997, Page(s): 1432–1436.
Tree structured filter bank for time-frequency decomposition of EEG signals, Sijercic, Z.; Agarwal, G., IEEE 17th Annual Conference Engineering in Medicine and Biology Society 1995, Volume: 2, 1995, Page(s): 991–992.
EEG signal compression with ADPCM subband coding, Sijercic, Z.; Agarwal, G.C.; Anderson, C.W., IEEE 39th Midwest symposium on Circuits and Systems, Volume: 2, 1996, Page(s): 695–698.
Use of chaotic modeling for transmission of EEG data, Kavitha, V.; Narayana Dutt, D., ICICS Proceedings of 1997 International Conference on Information, Communications and Signal Processing, 1997. Volume: 3, 1997, Page(s): 1262–1265.
Spatio-temporal EEG information transfer in an episode of epilepsy, A.M. Albano et al Nonlinear Dynamics and Brain Functioning (eds.-N. Pradhan, P.E. Rapp and R. Sreenivasan), Nova Science Publishers, Newyork, 199, Page(s): 411–434.
Entropy of brain rhythms: normal versus injury EEG, Thakor, N.V.; Paul, J.; Tong, S.; Zhu, Y.; Bezerianos, A., Proceedings of the 11th IEEE Signal Processing Workshop on Statistical Signal Processing, 2001, Page(s): 261–264
A lossless compression algorithm for multichannel EEG, Ke Chu Yi; Mingui Sun; Ching Chung Li; Sclabassi, R.J., Proceedings of the First Joint BMES/EMBS Conference, 1999. Volume: 1, 1999, Page(s): 429
Long-term EEG compression for intensive-care settings, Agarwal, R.; Gotman, J. IEEE Engineering in Medicine and Biology Magazine, Volume: 20 Issue: 5, Sept.-Oct. 2001, Page(s): 23–29
Vector quantization for compression of multichannel ECG, Mammen, C.P.; Ramamurthi, B., IEEE Transactions on Biomedical Engineering, Volume: 37 Issue:9, Sept. 1990, Page(s): 821–825.
Multichannel ECG data compression by multirate signal processing and transform domain coding techniques, Cetin, A.E.; Koymen, H.; Aydin, M.C., IEEE Transactions on Biomedical Engineering, Volume: 40 Issue:5, May 1993,Page(s): 495–499
A multichannel template based data compression algorithm, Paggetti, C.; Lusini, M.; Varanini, M.; Taddei, A.; Marchesi, C., Computers in Cardiology 1994, Page(s): 629–632
Compression of multichannel ECG through multichannel long-term prediction Cohen, A.; Zigel, Y., IEEE Engineering in Medicine and Biology Magazine, Volume: 17 Issue:1, Jan.-Feb. 1998, Page(s): 109–115
Near-best WPT compression of polysomnograms, Niederholz, J.; Taswell, C., Proceedings of the First Joint BMES/EMBS Conference, Volume: 2, 1999, Page(s): 961.
Quality controlled compression of polysomnograms, Taswell, C.; Niederholz, J., Proceedings of the First Joint BMES/EMBS Conference, 1999, Volume: 2, 1999, Page(s): 944.
Multichannel ECG compression using multichannel adaptive vector quantization, Shaou-Gang Miaou; Heng-Lin Yen, IEEE Transactions on Biomedical Engineering, Volume: 48 Issue: 10, Oct. 2001, Page(s): 1203–1207
Multichannel ECG data compression method based on a new modeling method Prieto, A.; Mailhes, C., Computers in Cardiology, 2001, Page(s): 261–264
Gilbert Strang and Truong Ngugen.: Wavelets and Filterbanks, Cambridge University Press, 1996.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2002 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Gopikrishna, D., Makur, A. (2002). A High Performance Scheme for EEG Compression Using a Multichannel Model. In: Sahni, S., Prasanna, V.K., Shukla, U. (eds) High Performance Computing — HiPC 2002. HiPC 2002. Lecture Notes in Computer Science, vol 2552. Springer, Berlin, Heidelberg. https://doi.org/10.1007/3-540-36265-7_42
Download citation
DOI: https://doi.org/10.1007/3-540-36265-7_42
Published:
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-00303-8
Online ISBN: 978-3-540-36265-4
eBook Packages: Springer Book Archive