Skip to main content

Rapid Impingement Detection System with Uniform Sampling for Ball-and-Socket Joint

  • Chapter
  • First Online:

Abstract

Detecting the position and the level of joint impingement is often a key to computer-aided surgical plan to normalize joint kinematics. So far most of the current impingement detection methods for ball-and-socket joint are not efficient or only report a few collided points as the detection results. In this chapter, we present a novel real-time impingement detection system with rapid memory-efficient uniform sampling and surface-to-surface distance measurement feature to estimate the overall impingement. Our system describes near-spherical objects in spherical coordinate system, which reduces the space complexity and the computation costs. The sampling design further reduces the memory cost by generating uniform sampling orientations. The rapid and accurate impingement detection with surface-to-surface distance measurement can provide more realistic detailed information to estimate the overall impingement on the ball-and-socket joint, which is particularly useful for computer-aided surgical plan.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Ganz R, Parvizi J, Beck M, Leunig M, Notzli H, Siebenrock KA (2003) Femoroacetabular impingement: A cause for osteoarthritis of the hip. Clinical Orthopaedics and Related Research 417:112–120

    Google Scholar 

  2. Wisniewski SJ, Grogg B (2006) Femoroacetabular impingement: An overlooked cause of hip pain. American Journal of Physical Medicine and Rehabilitation 85:546–549

    Article  Google Scholar 

  3. Teschner M, Kimmerle S, Heidelberger B, Zachmann G, Raghupathi L, Fuhrmann A, Cani MP, Faure F, Magnenat-Thalmann N, Strasser W, Volino P (2005) Collision detection for deformable objects. Computer Graphics Forum 24(1):61–81

    Article  Google Scholar 

  4. Kockara S, Halic T, Iqbal K, Bayrak C, Rowe R (2007) Collision detection: A survey. Systems, Man and Cybernetics, ISIC. IEEE:4046–4051

    Google Scholar 

  5. O’Sullivan C, Dingliana J (1999) Real-time collision detection and response using sphere-trees. In: Proceedings of the Spring Conference in Computer Graphics, Bratislava. pp 83–92

    Google Scholar 

  6. Dinesh M, Jonathan DC, Stefan G (1996) Collision detection: Algorithms and applications. Algorithms for Robot Motion and Manipulation 129–142

    Google Scholar 

  7. Gottschalk S, Lin M, Manocha D (1996) Obb-tree: A hierarchical structure for rapid interference detection. In: Computer Graphics (SIGGRAPH ’96), pp. 171–180

    Google Scholar 

  8. Fuhrmann A, Sobottka G, Groß C (2003) Distance fields for rapid collision detection in physically based modeling. In: International Conference on Computer Graphics and Vision, Keldysh Inst. of Applied Mathematics, pp. 58–65

    Google Scholar 

  9. Sud A, Otaduy MA, Manocha D (2004) DiFi: Fast 3D distance field computation using graphics hardware. Computer Graphics Forum (Proc. Eurographics) 23(3):557–566

    Article  Google Scholar 

  10. Sigg C, Peikert R, Gross M (2003) Signed distance transform using graphics hardware. In: IEEE Visualization 2003, IEEE Computer Society Press, pp. 83–90

    Google Scholar 

  11. Sarni S, Maciel A, Boulic R, Thalmann D (2004) Evaluation and visualization of stress and strain on soft biological tissues in Contact. In: International Conference on Shape Modeling and Applications, pp. 255–262

    Google Scholar 

  12. Yoshida H, Faust A, Wilckens J, Kitagawa M, Fetto J, Chao E (2006) Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living. Journal of Biomechanics 39(11):1996–2004

    Article  Google Scholar 

  13. Hu Q, Langlotz U, Lawrence J, Langlotz F, Nolte LP (2001) A fast impingement detection algorithm for computer-aided orthopedic surgery. Journal of Computer Aided Surgery 6(2):104–110

    Article  Google Scholar 

  14. Kubiak-Langer M, Tannast M, Murphy SB, Siebenrock KA, Langlotz F (2007) Range of motion in anterior femoroacetabular impingement. Clinical Orthopedics and Related Research 458:117–124

    Google Scholar 

  15. Maciel A, Boulic R, Thalmann D (2007) Efficient collision detection within deforming spherical sliding contact. IEEE Transactions on Visualization and Computer Graphics 13(3): 518–529

    Article  Google Scholar 

  16. Praun E, Hoppe H (2003) Spherical parametrization and remeshing. In: ACM SIGGRAPH 2003, pp. 340–349

    Google Scholar 

  17. Nishio H, Altaf-Ul-Amin Md, Kurokawa K, Kanaya S (2006) Spherical SOM and arrangement of neurons using helix on sphere. IPSJ Transactions on Mathematical Modeling and Its Applications 47:56–60

    Google Scholar 

  18. Cai D, Lee WS, Joslin C (2008) Rapid ball-and-socket joint collision detection. In: IEEE International Workshop on Medical Measurements and Applications, pp. 25–28

    Google Scholar 

Download references

Acknowledgments

This project is funded by NSERC Discovery grant. We appreciate Andrew Speirs (Division of Orthopaedic Surgery, Ottawa Hospital-General Campus) for the advices on CT data segmentation tool, Matt Kennedy (Biomedical Engineering, University of Ottawa) for the range of motion data, and Anna Conway (Division of Orthopaedic Surgery, Ottawa Hospital-General Campus) for coordinating CT data collection.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ding Cai .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2009 Springer-Verlag London

About this chapter

Cite this chapter

Cai, D., Lee, WS., Joslin, C., Beaulé, P. (2009). Rapid Impingement Detection System with Uniform Sampling for Ball-and-Socket Joint. In: Magnenat-Thalmann, N., Zhang, J., Feng, D. (eds) Recent Advances in the 3D Physiological Human. Springer, London. https://doi.org/10.1007/978-1-84882-565-9_12

Download citation

  • DOI: https://doi.org/10.1007/978-1-84882-565-9_12

  • Published:

  • Publisher Name: Springer, London

  • Print ISBN: 978-1-84882-564-2

  • Online ISBN: 978-1-84882-565-9

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics