Skip to main content

Investigation of the Human Factors, Usability and User Experience of Patient Monitors used in a Hospital Setting

  • Conference paper
  • First Online:
Book cover Human Systems Engineering and Design (IHSED 2018)

Abstract

According to the recent literature, approximately 250,000 deaths occur annually in U.S. hospitals resulting from medical error, making it the 3rd leading cause of death. One of the most commonly used devices in hospitals is the Patient Monitor (PM), a device which constantly monitors the vital signs of the patient. In this study, nurses and physicians who regularly interact with patient monitors were surveyed on their perceptions of the usability of the PMs they use on a regular basis. Results indicate that clinicians appeared to be mostly satisfied with the general usability of the monitors, particularly in terms of the information being presented and how it is presented. However, participants pointed out problems with the menu navigation during moments of high stress and the high frequency of false alarms. Also, participants expressed the desire to see additional information displayed on screen.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Makary, M.A., Daniel, M.: Medical error—the third leading cause of death in the US. BMJ 353, i2139 (2016)

    Article  Google Scholar 

  2. Wiklund, M.: Fitting human factors in the product development process. MDDI Online. https://www.mddionline.com/fitting-human-factors-product-development-process. Accessed 09 July 2018

  3. Cvach, M.: Monitor alarm fatigue: an integrative review. Biomed. Instrum. Technol. 46(4), 268–277 (2012)

    Article  Google Scholar 

  4. Lawless, S.T.: Crying wolf: false alarms in a pediatric intensive care unit. Crit. Care Med. 22(6), 981–985 (1994)

    Article  MathSciNet  Google Scholar 

  5. Cook, R.I., Woods, D.D.: Adapting to new technology in the operating room. Hum. Factors 38(4), 593–613 (1996)

    Article  Google Scholar 

  6. Drews, F.A.: Patient monitors in critical care: lessons for improvement. In: Henriksen, K., Battles, J.B., Keyes, M.A., Grady, M.L. (eds.) Advances in Patient Safety: New Directions and Alternative Approaches. Performance and Tools, vol. 3. Agency for Healthcare Research and Quality (US), Rockville (2008)

    Google Scholar 

  7. Koch, S.H., et al.: Intensive care unit nurses’ information needs and recommendations for integrated displays to improve nurses’ situation awareness. J. Am. Med. Inform. Assoc. JAMIA 19(4), 583–590 (2012)

    Article  Google Scholar 

  8. Görges, M., Kück, K., Koch, S.H., Agutter, J., Westenskow, D.R.: A far-view intensive care unit monitoring display enables faster triage. Dimens. Crit. Care Nurs. DCCN 30(4), 206–217 (2011)

    Article  Google Scholar 

  9. Görges, M., Westenskow, D.R., Markewitz, B.A.: Evaluation of an integrated intensive care unit monitoring display by critical care fellow physicians. J. Clin. Monit. Comput. 26(6), 429–436 (2012)

    Article  Google Scholar 

  10. Koch, S.H., Staggers, N., Weir, C., Agutter, J., Liu, D., Westenskow, D.R.: Integrated information displays for ICU nurses: field observations, display design, and display evaluation. In: Proceedings of the Human Factors and Ergonomics Society Annual Meeting. vol. 54, no. 12, pp. 932–936 (2010)

    Article  Google Scholar 

  11. Koch, S.H., et al.: Evaluation of the effect of information integration in displays for ICU nurses on situation awareness and task completion time: a prospective randomized controlled study. Int. J. Med. Inf. 82(8), 665–675 (2013)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Evismar Andrade .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Andrade, E. et al. (2019). Investigation of the Human Factors, Usability and User Experience of Patient Monitors used in a Hospital Setting. In: Ahram, T., Karwowski, W., Taiar, R. (eds) Human Systems Engineering and Design. IHSED 2018. Advances in Intelligent Systems and Computing, vol 876. Springer, Cham. https://doi.org/10.1007/978-3-030-02053-8_54

Download citation

Publish with us

Policies and ethics