Skip to main content

Generating Virtual Chromoendoscopic Images and Improving Detectability and Classification Performance of Endoscopic Lesions

  • Conference paper
  • First Online:
Book cover Domain Adaptation and Representation Transfer and Medical Image Learning with Less Labels and Imperfect Data (DART 2019, MIL3ID 2019)

Abstract

Endoscopy is a standard method for the diagnosis and detection of colorectal lesions. As a method to enhance the detectability of lesions, the effectiveness of pancolonic chromoendoscopy with indigocarmine has been reported. On the other hand, computer-aided diagnosis (CAD) has attracted attention. However, existing CAD systems are mainly for white light imaging (WLI) endoscopy, and the effect of the combination of CAD and indigocarmine dye spraying is not clear. Besides, it is difficult to gather a lot of indigocarmine dye-sprayed (IC) images for training. Here, we propose image-to-image translation from WLI to virtual indigocarmine dye-sprayed (VIC) images based on unpaired cycle-consistent Generative Adversarial Networks. Using this generator as preprocess part, we constructed detection models to evaluate the effectiveness of VIC translation for localization and classification of lesions. We also compared the localization and classification performance with and without image augmentation by using generated VIC images. Our results show that the model trained on IC and VIC images had the highest performance in both localization and classification. Therefore, VIC images are useful for the augmentation of IC images.

A. Fukuda and T. Miyamoto—Contributed equally to this work.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Adler, A., Pohl, H., Papanikolaou, I.S., et al: A prospective randomized study on narrow-band imaging versus conventional colonoscopy for adenoma detection: does NBI induce a learning effect? Gut 57 (2008)

    Google Scholar 

  2. Ahn, S.B., Han, D.S., Bae, J.H., et al.: The miss rate for colorectal adenoma determined by quality-adjusted, back-to-back colonoscopies. Gut Liver 6, 64–70 (2012)

    Article  Google Scholar 

  3. Brooker, J.C., Saunders, B.P., Shah, S.G., et al.: Total colonic dye-spray increases the detection of diminutive adenomas during routine colonoscopy: a randomized controlled trial. Gastrointest. Endosc. 56, 333–338 (2002)

    Article  Google Scholar 

  4. Corley, D., Jensen, C., Marks, A., et al.: Adenoma detection rate and risk of colorectal cancer and death. N. Engl. J. Med. 370, 2541 (2014)

    Article  Google Scholar 

  5. Engelhardt, S., De Simone, R., Full, P.M., et al.: Improving surgical training phantoms by hyperrealism: deep unpaired image-to-image translation from real surgeries. arXiv pre-prints arXiv:1806.03627 (2018)

  6. Isola, P., Zhu, J., Zhou, T., Efros, A.A.: Image-to-image translation with conditional adversarial networks. arXiv preprint arXiv:1611.07004 (2016)

  7. Kaminski, M., Regula, J., Kraszewska, E., et al: Quality indicators for colonoscopy and the risk of interval cancer. N. Engl. J. Med. 362 (2010)

    Google Scholar 

  8. Ki Min, J., Kwak, M., Myung Cha, J.: Overview of deep learning in gastrointestinal endoscopy. Gut Liver 13(4), 388–393 (2019)

    Article  Google Scholar 

  9. Kumar, S., Thosani, N., Ladabaum, U., et al.: Adenoma miss rates associated with a 3-minute versus 6-minute colonoscopy withdrawal time: a prospective, randomized trial. Gastrointest. Endosc. 85, 1273–1280 (2017)

    Article  Google Scholar 

  10. Mori, Y., Kudo, S.E., Berzin, T.M., et al.: Computer-aided diagnosis for colonoscopy. Endoscopy 49, 813–819 (2017)

    Article  Google Scholar 

  11. Pohl, J., Lotterer, E., Balzer, C., et al.: Computed virtual chromoendoscopy versus standard colonoscopy with targeted indigocarmine chromoscopy: a randomised multicentre trial. Gut 58, 73–78 (2009)

    Article  Google Scholar 

  12. Pohl, J., Schneider, A., Vogell, H., et al.: Pancolonic chromoendoscopy with indigo carmine versus standard colonoscopy for detection of neoplastic lesions: a randomised two-centre trial. Gut 60, 485–490 (2011)

    Article  Google Scholar 

  13. Redmon, J., Farhadi, A.: YoLov3: an incremental improvement. arXiv preprint arXiv:1804.02767 (2018)

  14. Repici, A., Wallace, M.B., East, J.E., et al.: Efficacy of per-oral methylene blue formulation for screening colonoscopy\(^{\rm a}\). Gastroenterology S0016–5085(19), 2198–2207 (2019)

    Google Scholar 

  15. Rex, D.K., Helbig, C.C.: High yields of small and flat adenomas with high-definition colonoscopes using either white light or narrow band imaging. Gastroenterology 133, 42–47 (2007)

    Article  Google Scholar 

  16. Urban, G., Tripathi, P., Alkayali, T., et al.: Deep learning localizes and identifies polyps in real time with 96% accuracy in screening colonoscopy. Gastroenterology 155, 1069–1078 (2018)

    Article  Google Scholar 

  17. Wang, P., Xiao, X., Glissen Brown, J.R., et al.: Development and validation of a deep-learning algorithm for the detection of polyps during colonoscopy. Nat. Biomed. Eng. 2, 741–748 (2018)

    Article  Google Scholar 

  18. Yi, Z., Zhang, H., Tan, P., et al.: DualGAN: unsupervised dual learning for image-to-image translation. arXiv preprint arXiv:1704.02510 (2017)

  19. Zhong, Z., Zheng, L., Kang, G., et al.: Random erasing data augmentation. arXiv preprint arXiv:1708.04896 (2017)

  20. Zhu, J., Park, T., Isola, P., et al.: Unpaired image-to-image translation using cycle-consistent adversarial networks. arXiv preprint arXiv:1703.10593 (2017)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Akihiro Fukuda .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Switzerland AG

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Fukuda, A., Miyamoto, T., Kamba, S., Sumiyama, K. (2019). Generating Virtual Chromoendoscopic Images and Improving Detectability and Classification Performance of Endoscopic Lesions. In: Wang, Q., et al. Domain Adaptation and Representation Transfer and Medical Image Learning with Less Labels and Imperfect Data. DART MIL3ID 2019 2019. Lecture Notes in Computer Science(), vol 11795. Springer, Cham. https://doi.org/10.1007/978-3-030-33391-1_12

Download citation

  • DOI: https://doi.org/10.1007/978-3-030-33391-1_12

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-030-33390-4

  • Online ISBN: 978-3-030-33391-1

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics