Abstract
Wireless Body Area Networks (WBANs) envision the realization of several applications which involve the physiological monitoring and/or feedback generations according to the monitored vital signs. These applications range from telehealth or telemedicine to sports and entertainment. SmartBAN provides the physical (PHY) and medium access control (MAC) layer specifications for a simplified and efficient execution of these applications. This paper provides an overview of the existing WBAN use-cases and categorizes them according to their data rate requirements. The SmartBAN performance is thoroughly investigated for the implementation of these diverse applications. For performance evaluation, packet reception rate (PRR), aggregated throughput and latency are taken as the primary quality of service (QoS) criteria. We assume two different channel models, namely static CM3B (S-CM3B) and realistic CM3B (R-CM3B), and different options for the slot durations to further comprehend the results. The simulation results indicate that smaller slot duration performs better in terms of PRR and latency while longer slot durations are more effective to support high data rate application throughput requirements.
This research was supported in part by the European Union’s Horizon 2020 Research and Innovation Program under Grant 668995, in part by the European Union Regional Development Fund through the framework of the Tallinn University of Technology Development Program 2016–2022, and in part by the Estonian Research Council under Grant PUT-PRG424.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Movassaghi, S., Abolhasan, M., Lipman, J., Smith, D., Jamalipour, A.: Wireless body area networks: a survey. IEEE Commun. Surv. Tutorials 16(3), 1658–1686 (2014)
Scazzoli, D., Kumar, A., Sharma, N., Magarini, M., Verticale, G.: Fault recovery in time-synchronized mission critical ZigBee-based wireless sensor networks. Int. J. Wirel. Inf. Netw. 24(3), 268–277 (2017)
Scazzoli, D., Kumar, A., Sharma, N., Magarini, M., Verticale, G.: A novel technique for ZigBee coordinator failure recovery and its impact on timing synchronization. In: Proceedings of IEEE 27th Annual International Symposium on Personal, Indoor, and Mobile Radio Communication (PIMRC), pp. 1–5. IEEE, Valencia (2016)
IEEE Standard for Local and metropolitan area networks - Part 15.6: Wireless Body Area Networks. https://ieeexplore.ieee.org/document/6161600. Accessed 25 July 2019
Smart Body Area Networks (SmartBAN): System Description. http://www.etsi.org/deliver/etsi_tr/103300_103399/103394/01.01.01_60/tr_103394v010101p.pdf. Accessed 25 July 2019
Smith, D.B., Hanlen, L.W.: Channel modeling for wireless body area networks. In: Mercier, P.P., Chandrakasan, A.P. (eds.) Ultra-Low-Power Short-Range Radios. ICS, pp. 25–55. Springer, Cham (2015). https://doi.org/10.1007/978-3-319-14714-7_2
Alam, M. M., Hamida, E. B.: Performance evaluation of IEEE 802.15.6 MAC for wearable body sensor networks using a space-time dependent radio link model. In: Proceedings of IEEE/ACS 11th International Conference on Computer Systems and Applications (AICCSA), pp. 441–448. IEEE, Qatar (2014)
Smart Body Area Network (SmartBAN): Enhanced Ultra-Low Power Physical Layer. http://www.etsi.org/deliver/etsi_ts/103300_103399/103326/01.01.01_60/ts_103326v010101p.pdf. Accessed 26 May 2018
Smart Body Area Network (SmartBAN): Low Complexity Medium Access Control (MAC) for SmartBAN. http://www.etsi.org/deliver/etsi_ts/103300_103399/103325/01.01.01_60/ts_103325v010101p.pdf. Accessed 26 May 2018
Khan, R., Alam, M. M.: Joint PHY-MAC realistic performance evaluation of body-to-body communication in IEEE 802.15.6 and SmartBAN. In: Proceedings of IEEE 12th International Symposium on Medical Information & Communication Technology. IEEE, Australia (2018)
Simon, M.K., Alouini, M.S.: Digital Communication over Fading Channel, 2nd edn. Wiley, New York (2005)
Arnon, S., Bhastekar, D., Kedar, D., Tauber, A.: A comparative study of wireless communication network configurations for medical applications. IEEE Wirel. Commun. 10(1), 56–61 (2003)
Chakraborty, C., Gupta, B., Ghosh, S.: A review on telemedicine-based WBAN framework for patient monitoring. Telemedicine J. E-health: Official J. Am. Telemedicine Assoc. 19 (2013)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 ICST Institute for Computer Sciences, Social Informatics and Telecommunications Engineering
About this paper
Cite this paper
Khan, R., Alam, M.M. (2019). SmartBAN Performance Evaluation for Diverse Applications. In: Mucchi, L., Hämäläinen, M., Jayousi, S., Morosi, S. (eds) Body Area Networks: Smart IoT and Big Data for Intelligent Health Management. BODYNETS 2019. Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering, vol 297. Springer, Cham. https://doi.org/10.1007/978-3-030-34833-5_19
Download citation
DOI: https://doi.org/10.1007/978-3-030-34833-5_19
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-34832-8
Online ISBN: 978-3-030-34833-5
eBook Packages: Computer ScienceComputer Science (R0)