Abstract
The treatment of hepatic lesions with radio-frequency (RF) ablation has become a promising minimally invasive alternative to surgical resection during the last decade. In order to achieve treatment qualities similar to surgical R0 resections, patient specific mathematical modeling and simulation of the biophysical processes during RF ablation are valuable tools. They allow for an a priori estimation of the success of the therapy as well as an optimization of the therapy parameters. In this report we discuss our recent efforts in this area: a model of partial differential equations (PDEs) for the patient specific numerical simulation of RF ablation, the optimization of the probe placement under the constraining PDE system and the identification of material parameters from temperature measurements. A particular focus lies on the uncertainties in the patient specific tissue properties. We discuss a stochastic PDE model, allowing for a sensitivity analysis of the optimal probe location under variations in the material properties. Moreover, we optimize the probe location under uncertainty, by considering an objective function, which is based on the expectation of the stochastic distribution of the temperature distribution. The application of our models and algorithms to data from real patient’s CT scans underline their applicability.
Mathematics Subject Classification (2000). 35Q93 and 49J20.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
I. Altrogge, T. Kröger, T. Preusser, C. Büskens, P.L. Pereira, D. Schmidt, A. Weihusen, H.-O. Peitgen. Towards Optimization of Probe Placement for Radio-Frequency Ablation. Proc. MICCAI, Lect. Not. Comp. Sci. 4190, 486–493, 2006.
I. Altrogge, T. Preusser, T. Kröger, et al., Multi-Scale Optimization of the Probe Placement for Radio-Frequency Ablation. Acad. Radiol. 14(11), 1310–1324, 2007.
I. Altrogge, Optimization of the Probe Placement for Radiofrequency Ablation. PhD thesis, University of Bremen, Germany, 2009.
I. Altrogge, T. Pätz, T. Kröger, T. Preusser. Optimization and Fast Estimation of Vessel Cooling for RF Ablation. Proc. IFMBE. 25/IV, 1202–1205 (2009).
S.J. Benson, L.C. McInnes, J.J. Moré, J. Sarich. Scalable Algorithms in Optimization: Computational Experiments. Preprint ANL/MCS-P1175-0604, Mathematics and Computer Science, Argonne National Laboratory, Argonne, IL, 2004; in Proceedings of the 10th AIAA/ISSMO Multidisciplinary Analysis and Optimization (MA‖O) Conference, Albany, NY, 2004.
S. Gratton, A. Sartenaer, Ph.L. Toint. Recursive Trust-Region Methods for Multiscale Nonlinear Optimization. SIAM J Optim., 19(1), 414–444 (2008).
D. Hämmerich, S.T. Staelin, J.Z. Tsai, S. Tungjikusolmun, D.M. Mahvi, J.G. Webster. In Vivo Electrical Conductivity of Hepatic Tumours.Physiol. Meas. 24, 251–260 (2003).
T. Kröger, T. Pätz, I. Altrogge, A. Schenk, K.S. Lehmann, B.B. Frericks, J.-P. Ritz, H.-O. Peitgen, T. Preusser, Fast Estimation of the Vascular Cooling in RFA Based on Numerical Simulation, The Open Biomed. Eng. J. 4, 16–26 (2010).
T. Kröger, S. Pannier, M. Kaliske, I. Altrogge, W. Graf, T. Preusser, Optimal Applicator Placement in Hepatic Radiofrequency Ablation on the Basis of Rare Data. Computer Methods in Biomechanics and Biomedical Engineering, to appear, 2009.
T. Kröger, I. Altrogge, O. Konrad, R.M. Kirby, T. Preusser. Visualization of Parameter Sensitivity Analyses resulting from Stochastic Collocation Methods. Proc. Simulation and Visualization (SimVis), Magdeburg, 2008.
T. Kröger, I. Altrogge, T. Preusser, P.L. Pereira, D. Schmidt, A. Weihusen, H.-O. Peitgen. Numerical Simulation of Radio Frequency Ablation with State-Dependent Material Parameters in Three Space Dimensions. Proc. MICCAI, Lect. Not. Comp. Sci. 4191, 380–388, 2006.
D.D. Mosser, A.W. Caron, L. Bourget, et al., Role of human heat shock protein hsp70 in protection against stress-induced apoptosis. Mol. Cel. Biol. 17, 9, 1997.
Mulier, S.; Ni, Y.; Jamart, J.; Michel, L. et al., Radiofrequency ablation versus resection for resectable colorectal liver metastases: Time for a randomized trial? Ann. Sur. Oncology 15 1, 144–157, 2007.
T. Pätz, T. Kröger, T. Preusser. Simulation of Radiofrequency Ablation including Water Evaporation. Proc. IFMBE. 25/IV, 1287–1290 (2009).
T. Stein, Untersuchungen zur Dosimetrie der hochfrequenzstrominduzierten interstitiellen Thermotherapie in bipolarer Technik. Fortschritte in der Lasermedizin, vol. 22, Müller und Berlien, 2000.
H. Tiesler, R.M. Kirby, D. Xiu, T. Preusser, Stochastic collocation for optimal control problems with stochastic PDE constraints. In preparation.
H. Tiesler, C. Büskens, D. Hämmerich, T. Preusser, On the Optimization of Large Scale nonlinear PDE Systems with Application to Parameter Identification for RF Ablation. In preparation.
Zurbuchen, U.; Holmer, C.; Lehmann, K. S.; et al., Determination of the temperaturedependent electric conductivity of liver tissue ex vivo and in vivo: Importance for therapy planning for the radiofrequency ablation of liver tumours. Int. J. Hyperthermia, 26, 1, 26–33, 2010.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer Basel AG
About this chapter
Cite this chapter
Altrogge, I., Büskens, C., Kröger, T., Peitgen, HO., Preusser, T., Tiesler, H. (2012). Modeling, Simulation and Optimization of Radio Frequency Ablation. In: Leugering, G., et al. Constrained Optimization and Optimal Control for Partial Differential Equations. International Series of Numerical Mathematics, vol 160. Birkhäuser, Basel. https://doi.org/10.1007/978-3-0348-0133-1_25
Download citation
DOI: https://doi.org/10.1007/978-3-0348-0133-1_25
Published:
Publisher Name: Birkhäuser, Basel
Print ISBN: 978-3-0348-0132-4
Online ISBN: 978-3-0348-0133-1
eBook Packages: Mathematics and StatisticsMathematics and Statistics (R0)