Skip to main content

Inter-slice Correspondence for 2D Ultrasound-Guided Procedures

  • Conference paper
  • First Online:
Book cover Clinical Image-Based Procedures. Translational Research in Medical Imaging (CLIP 2013)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 8361))

Included in the following conference series:

  • 771 Accesses

Abstract

This paper reports on a new computational methodology, inter-slice correspondence (ISC), for robustly aligning sets of 2D ultrasound (US) slices during image-guided medical procedures. Correspondences are derived from distinctive, local scale-invariant features, which are used in one-to-many matching of US slices in near real-time despite out-of-plane rotation, in addition to global in-plane similarity transforms, occlusion, missing tissue, US plane mirroring, changes in US probe depth settings. Experiments demonstrate that ISC can align manually-acquired US slices without probe tracking information in the context of image-guided neurosurgery, with an accuracy of 1.3 mm. A novel reconstruction-without-calibration application based on ISC is proposed, where 3D US reconstruction results are very similar to those obtained via traditional phantom-based calibration.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Prager, R.W., Ijaz, U.Z., Gee, A.H., Treece, G.M.: Three-dimensional ultrasound imaging. J. Eng. Med. 224, 192–223 (2010)

    Article  Google Scholar 

  2. Mercier, L., Lang, T., Lindsesth, F., Collins, D.L.: A review of calibration techniques for freehand 3-d ultrasound systems. Ultrasound Med. Biol. 31(4), 449–471 (2005)

    Article  Google Scholar 

  3. Khamene, A., Sauer, F.: A novel phantom-less spatial and temporal ultrasound calibration method. In: Duncan, J.S., Gerig, G. (eds.) MICCAI 2005. LNCS, vol. 3750, pp. 65–72. Springer, Heidelberg (2005)

    Google Scholar 

  4. Mercier, L., Del Maestro, R.F., Petrecca, K., Araujo, D., Haegelen, C., Collins, D.L.: Online database of clinical mr and ultrasound images of brain tumors. Med. Phys. 39, 3253 (2012)

    Article  Google Scholar 

  5. Kwitt, R., Vasconcelos, N., Razzaque, S., Aylward, S.: Recognition in ultrasound videos: where am i? In: Ayache, N., Delingette, H., Golland, P., Mori, K. (eds.) MICCAI 2012, Part III. LNCS, vol. 7512, pp. 83–90. Springer, Heidelberg (2012)

    Google Scholar 

  6. James Housden, R., Gee, A.H., Treece, G.M., Prager, R.W.: Sensorless reconstruction of freehand 3d ultrasound data. In: Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI 2006. LNCS, vol. 4191, pp. 356–363. Springer, Heidelberg (2006)

    Google Scholar 

  7. Laporte, C., Arbel, T.: Learning to estimate out-of-plane motion in ultrasound imagery of real tissue. MIA 15, 202–213 (2011)

    Google Scholar 

  8. Afsham, N., Najafi, M., Abolmaesumi, P., Rohling, R.: Out-of-plane motion estimation based on a rician-inverse gaussian model of rf ultrasound signals: speckle tracking without fully developed speckle. In: Proceedings of SPIE, vol. 8320, p. 832017-1 (2012)

    Google Scholar 

  9. Lowe, D.G.: Distinctive image features from scale-invariant keypoints. IJCV 60(2), 91–110 (2004)

    Article  Google Scholar 

  10. Bay, H., Tuytelaars, T., Gool, L.V.: Surf: speeded up robust features. CVIU 110(3), 346–359 (2008)

    Google Scholar 

  11. Mirota, D., Uneri, A., Schafer, S., Nithiananthan, S., Reh, D., Ishii, M., Gallia, G., Taylor, R., Hager, G., Siewerdsen, J.: Evaluation of a system for high-accuracy 3d image-based registration of endoscopic video to c-arm cone-beam ct for image-guided skull base surgery. IEEE TMI 32(7), 1215–1226 (2013)

    Google Scholar 

  12. Muja, M., Lowe, D.G.: Fast approximate nearest neighbors with automatic algorithm configuration. In: International Conference on Computer Vision, pp. 331–340 (2009)

    Google Scholar 

  13. Boctor, E., Iordachita, I., Fichtinger, G., Hager, G.: Ultrasound self-calibration. In: SPIE Medical Imaging, pp. 61412N–61412N (2006)

    Google Scholar 

  14. Wein, W., Khamene, A.: Image-based method for in-vivo freehand ultrasound calibration. In: SPIE Medical Imaging, vol. 6920 (2008)

    Google Scholar 

  15. Nelder, J.A., Mead, R.: A simplex method for function minimization. Comput. J. 7, 308–313 (1965)

    Article  MATH  Google Scholar 

Download references

Acknowledgements

This work was supported by NIH grants R01CA138419 and P41EB015898 and P41EB015902.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Matthew Toews .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer International Publishing Switzerland

About this paper

Cite this paper

Toews, M., Golby, A.J., Wells, W.M. (2014). Inter-slice Correspondence for 2D Ultrasound-Guided Procedures. In: Erdt, M., et al. Clinical Image-Based Procedures. Translational Research in Medical Imaging. CLIP 2013. Lecture Notes in Computer Science(), vol 8361. Springer, Cham. https://doi.org/10.1007/978-3-319-05666-1_18

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-05666-1_18

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-05665-4

  • Online ISBN: 978-3-319-05666-1

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics