Skip to main content

Predicting the Benefit of Using CADe in Screening Mammography

  • Conference paper
Breast Imaging (IWDM 2014)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 8539))

Included in the following conference series:

Abstract

The goal of computer-aided detection (CADe) in screening mammography is to help radiologist avoid missing breast cancer. Thus when designing a CADe system it is important to know how different methods and parameters would affect radiologists’ ability to use the system effectively. Short of conducting an observer study or a clinical trial, this is not possible. In this paper, we present preliminary results on a model that can predict how many additional cancers a radiologist would detect, if they used a CADe system. The model uses the results of radiologists’ reading of a set of screening mammograms without using CADe to predict the probability that a radiologist would miss a cancer when reading without CADe and the probability that the radiologist would recall the woman if CADe flagged the missed cancer. In our initial study, 8 radiologists read 300 screening mammograms containing 69 cancers with and without CADe. Our model predicted that on average a radiologist would detect 4.7 extra cancers while the actual number of extra cancers detected per radiologist was 3.6. Bootstrapping across readers, the 95% CI for the difference between the predicted and actual number of extra cancers was [-1.52, 3.30]. The overall ability of the model to discriminate between lesions detected as a result of CAD flag and other lesion examinations was moderately high, with c-index of 0.77 (95% CI of [0.6, 0.91]). We are currently conducting a study with larger number of radiologists and cases to obtain better estimates of the accuracy of our model.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Nishikawa, R.M., Schmidt, R.A., Linver, M.N., Edwards, A.V., Papaioannou, J., Stull, M.A.: Clinically Missed Cancer: How Effectively Can Radiologists Use Computer-Aided Detection? American Journal of Roentgenology 198, 708–716 (2012)

    Article  Google Scholar 

  2. Warren-Burhenne, L.J., Wood, S.A., D’Orsi, C.J., Feig, S.A., Kopans, D.B., O’Shaughnessy, K., Sickles, E.A., Tábar, L., Vyborny, C.J., Castellino, R.A.: Potential contribution of computer-aided detection to the sensitivity of screening mammography. Radiology 215, 554–562 (2000)

    Article  Google Scholar 

  3. Chan, H.-P., Doi, K., Vyborny, C.J., Schmidt, R.A., Metz, C.E., Lam, K.L., Ogura, T., Wu, Y., MacMahon, H.: Improvement in radiologists’ detection of clustered microcalcifications on mammograms: The potential of computer-aided diagnosis. Investigative Radiology 25, 1102–1110 (1990)

    Article  Google Scholar 

  4. Zheng, B., Swensson, R.G., Golla, S., Hakim, C.M., Shah, R., Wallace, L., Gur, D.: Detection and classification performance levels of mammographic masses under different computer-aided detection cueing environments. Acad. Radiol. 11, 398–406 (2004)

    Article  Google Scholar 

  5. Nishikawa, R., Edwards, A., Schmidt, R., Papaioannou, J., Linver, M.: Can radiologists recognize that a computer has identified cancers that they have overlooked? In: Proc. SPIE, vol. 6146, pp. 1–8 (2006)

    Google Scholar 

  6. Obuchowski, N.A.: Predicting Readers’ Diagnostic Accuracy with a New CAD Algorithm. Academic Radiology 18, 1412–1419 (2011)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer International Publishing Switzerland

About this paper

Cite this paper

Nishikawa, R.M., Bandos, A. (2014). Predicting the Benefit of Using CADe in Screening Mammography. In: Fujita, H., Hara, T., Muramatsu, C. (eds) Breast Imaging. IWDM 2014. Lecture Notes in Computer Science, vol 8539. Springer, Cham. https://doi.org/10.1007/978-3-319-07887-8_7

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-07887-8_7

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-07886-1

  • Online ISBN: 978-3-319-07887-8

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics