Abstract
Digital Breast Tomosynthesis (DBT) has the potential to replace or supplement Digital Mammography (DM). Studies have shown that it takes radiologists more time to read DBT examinations compared with DM. The slice separation of image volumes has been set to 1 mm on most systems. By using thicker slices review time could be reduced. This paper investigates the possibility of using 2 mm Average Intensity Pixel (AIP) slabs for image review. The thicker slabs were created using a method based on statistical artifact reduction and super-resolution. Six radiologists were presented with 20 sets of images containing 16 tumor masses and 8 micro-calcification clusters. They ranked 2 mm slabbed sets relative to standard 1 mm. Visibility (P = .0044) of micro-calcifications improved and there was no significant effect on mass visibility (P = .46). The results indicate that it is possible to review DBT-volumes with 2 mm slabs without compromising image quality.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Svahn, T., Andersson, I., Chakraborty, D., et al.: The diagnostic accuracy of dual-view digital mammography, single-view breast tomosynthesis and a dual-view combination of breast tomosynthesis and digital mammography in a free-response observer performance study. Rad. Prot. Dos. 139(1-3), 113–117 (2010)
Andersson, I., Ikeda, D.M., Zackrisson, S., et al.: Breast tomosynthesis and digital mammography: A comparison of breast cancer visibility and BIRADS classification in a population of cancers with subtle mammographic findings. Eur. Radiol. 18(12), 2817–2825 (2008)
Gur, D., Abrams, G.S., Chough, D.M., et al.: Digital breast tomosynthesis: Observer performance study. Am. J. Roentgenol. 193(2), 586–591 (2009)
Wallis, M.G., Moa, E., Zanca, F., et al.: Two-view and single-view tomosynthesis versus full-field digital mammography: High-resolution X-ray imaging observer study. Radiology 262(3), 788–796 (2012)
Good, W.F., Abrams, G.S., Catullo, V.J., et al.: Digital breast tomosynthesis: A pilot observer study. Am. J. Roentgenol. 190(4), 865–869 (2008)
Skaane, P., Gullien, R., Bjørndal, H., et al.: Digital breast tomosynthesis (DBT): Initial experience in a clinical setting. Acta Radiol. 53(5), 524–529 (2012)
Good, W.F., Abrams, G.S., Catullo, V.J., et al.: Digital breast tomosynthesis: A pilot observer study. AJR Am. J. Roentgenol. 190(4), 865–869 (2008)
Mertelmeier, T., Orman, J., Haerer, W., et al.: Optimizing filtered backprojection reconstruction for a breast tomosynthesis prototype device. In: Spie Medical Imaging, pp. 61420F-1–61420F-12. International Society for Optics and Photonics, Bellingham (2006)
Wu, T., Moore, R.H., Kopans, D.B.: Voting strategy for artifact reduction in digital breast tomosynthesis. Med. Phys. 33, 2461 (2006)
Wu, T., Moore, R.H., Rafferty, E.A., et al.: A comparison of reconstruction algorithms for breast tomosynthesis. Med. Phys. 31(9), 2636–2647 (2004)
Hu, Y.H., Zhao, B., Zhao, W.: Image artifacts in digital breast tomosynthesis: Investigation of the effects of system geometry and reconstruction parameters using a linear system approach. Med. Phys. 35(12), 5242–5252 (2008)
Zhang, Y., Chan, H.P., Sahiner, B., et al.: Investigation of the Z-axis resolution of breast tomosynthesis mammography systems. In: SPIE Medical Imaging, pp. 65104A-65104A-8. International Society for Optics and Photonics, Bellingham (2007)
Dustler, M., Andersson, I., Förnvik, D., et al.: A Study of the Feasibility of using slabbing to reduce Tomosynthesis Review Time. In: SPIE Medical Imaging, pp. 86731L–86731L. International Society for Optics and Photonics, Bellingham (2013)
Kopans, D., Gavenonis, S., Halpern, E., et al.: Calcifications in the breast and digital breast tomosynthesis. Breast J. 17(6), 638–644 (2011)
Sechopoulos, I., Ghetti, C.: Optimization of the acquisition geometry in digital tomosynthesis of the breast. Med. Phys. 36, 1199 (2009)
Abdurahman, S., Jerebko, A., Mertelmeier, T., Lasser, T., Navab, N.: Out-of-plane artifact reduction in tomosynthesis based on regression modeling and outlier detection. In: Maidment, A.D.A., Bakic, P.R., Gavenonis, S. (eds.) IWDM 2012. LNCS, vol. 7361, pp. 729–736. Springer, Heidelberg (2012)
Håkansson, M., Svensson, S., Zachrisson, S., et al.: ViewDEX: An efficient and easy-to-use software for observer performance studies. Rad. Prot. Dos. 139(1-3), 42–51 (2010)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2014 Springer International Publishing Switzerland
About this paper
Cite this paper
Dustler, M., Timberg, P., Tingberg, A., Zackrisson, S. (2014). Image Quality of Thick Average Intensity Pixel Slabs Using Statistical Artifact Reduction in Breast Tomosynthesis. In: Fujita, H., Hara, T., Muramatsu, C. (eds) Breast Imaging. IWDM 2014. Lecture Notes in Computer Science, vol 8539. Springer, Cham. https://doi.org/10.1007/978-3-319-07887-8_76
Download citation
DOI: https://doi.org/10.1007/978-3-319-07887-8_76
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-07886-1
Online ISBN: 978-3-319-07887-8
eBook Packages: Computer ScienceComputer Science (R0)