Abstract
This paper presents an investigation into a novel approach for an automated universal colourimetric test by chromaticity analysis. This work particularly focuses on how a well-adjusted harmony between computational complexity and biochemical analysis can reduce the associated cost and unlock the limit on conventional chemical practice. The proposed research goal encompasses the potential to the criteria- anytime anywhere access, low cost, rapid detection, better sensitivity, specificity and accuracy. Our method includes obtaining the amount of colour change for each instance by delta E calculation. The system can provide the result in any ambient condition from the trajectory of colour change using Euclidean distance in LAB colour space. The strategy is verified on plasmonic ELISA based diagnosis of tuberculosis (TB). TB detection by plasmonic ELISA is a challenging, demanding and a time-consuming diagnosis. Completing the computation in real time, we circumvent the obstacle liberating the TB diagnosis in less than 15 min.
Keywords
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Yetisen, A.K.: Holographic Sensors. Springer Theses (2014). doi:10.1007/978-3-319-13584-7
Cate, D.M., Adkins, J.A., Mettakoonpitak, J., Henry, C.S.: Recent developments in paper-based microfluidic devices. Anal. Chem. 87, 19–41 (2015). doi:10.1021/ac503968p
Yetisen, A.K., Martinez-Hurtado, J.L., Garcia-Melendrez, A., et al.: A smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests. Sens. Actuators B Chem. 196, 156–160 (2014). doi:10.1016/j.snb.2014.01.077
Suslick, K.S., Rakow, N.A., Sen, A.: Colorimetric sensor arrays for molecular recognition. Tetrahedron 60, 11133–11138 (2004). doi:10.1016/j.tet.2004.09.007
Qin, X., Wang, R., Tsow, F., et al.: A colorimetric chemical sensing platform for real-time monitoring of indoor formaldehyde. IEEE Sens. J. 15, 1545–1551 (2015). doi:10.1109/JSEN.2014.2364142
Luo, W., Greenbaum, A., Zhang, Y., Ozcan, A.: Synthetic aperture-based on-chip microscopy. Light Sci. Appl. (2015). doi:10.1038/lsa.2015.34
Shen, L., Hagen, J.A., Papautsky, I.: Point-of-care colorimetric detection with a smartphone. Lab Chip 12, 4240 (2012). doi:10.1039/c2lc40741h
Tania, M.H., Lwin, K.T., Hossain, M.A.: Computational complexity of image processing algorithms for an intelligent mobile enabled tongue diagnosis scheme. In: 10th International Conference on Software, Knowledge, Information Management & Applications, Chengdu, China, p. 15 (2016). doi:10.1109/SKIMA.2016.7916193
WHO: Tuberculosis (Fact sheet). In: Media Centre. WHO (2016)
UN Sustainable Development Goals: 17 Goals to Transform Our World
Blakemore, R., Story, E., Helb, D., et al.: Evaluation of the analytical performance of the Xpert MTB/RIF assay. J. Clin. Microbiol. 48, 2495–2501 (2010). doi:10.1128/JCM.00128-10
UKVI: Tuberculosis tests for visa applicants - GOV. UK (2016)
NHS Tuberculosis (TB) - Diagnosis - NHS Choices. http://www.nhs.uk/Conditions/Tuberculosis/Pages/Diagnosis.aspx. Accessed 12 Jan 2017
Tsai, T.-T., Shen, S.-W., Cheng, C.-M., Chen, C.-F.: Paper-based tuberculosis diagnostic devices with colorimetric gold nanoparticles. Sci. Technol. Adv. Mater. 14, 44404 (2013). doi:10.1088/1468-6996/14/4/044404
Osman, M.K., Mashor, M.Y., Jaafar, H.: Detection of mycobacterium tuberculosis in Ziehl-Neelsen stained tissue images using Zernike moments and hybrid multilayered perceptron network. In: 2010 IEEE International Conference on Systems, Man, and Cybernetics, pp. 4049–4055. IEEE (2010). doi:10.1109/ICSMC.2010.5642191
Khademhosseini, A.: Nano/microfluidics for diagnosis of infectious diseases in developing countries. Adv. Drug Deliv. Rev. 62, 449–457 (2011). doi:10.1016/j.addr.2009.11.016.Nano/microfluidics
Wang, S., Xu, F., Demirci, U.: Advances in developing HIV-1 viral load assays for resource-limited settings. Biotechnol. Adv. 28, 770–781 (2010). doi:10.1016/j.biotechadv.2010.06.004
Shir, D., Ballard, Z.S., Ozcan, A.: Flexible plasmonic sensors. IEEE J. Sel. Top. Quantum Electron. (2016). doi:10.1109/JSTQE.2015.2507363
de la Rica, R., Stevens, M.M.: Plasmonic ELISA for the ultrasensitive detection of disease biomarkers with the naked eye. Nat. Nanotechnol. 7, 821–824 (2012). doi:10.1038/nnano.2012.186
Colorimetry - Part 4: CIE 1976 L*a*b* Colour Space. CIE (2007)
Mahy, M., Van Eycken, L., Oosterlinck, A.: Evaluation of uniform color spaces developed after the adoption of CIELAB and CIELUV. Color Res. Appl. 19, 105–121 (1994). doi:10.1111/j.1520-6378.1994.tb00070.x
Sharma, G.: Digital Color Imaging Handbook, 1.7.2. CRC Press, Boca Raton (2003)
Acknowledgement
This research is supported by the Erasmus Mundus FUSION project, British Council Newton Institutional Links and Newton-Ungku Omar Fund. This is a collaborative research project between Anglia Ruskin University (UK) and Universiti Putra Malaysia (Malaysia).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Springer International Publishing AG
About this paper
Cite this paper
Hoque Tania, M. et al. (2017). An Automated Colourimetric Test by Computational Chromaticity Analysis: A Case Study of Tuberculosis Test. In: Fdez-Riverola, F., Mohamad, M., Rocha, M., De Paz, J., Pinto, T. (eds) 11th International Conference on Practical Applications of Computational Biology & Bioinformatics. PACBB 2017. Advances in Intelligent Systems and Computing, vol 616. Springer, Cham. https://doi.org/10.1007/978-3-319-60816-7_38
Download citation
DOI: https://doi.org/10.1007/978-3-319-60816-7_38
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-60815-0
Online ISBN: 978-3-319-60816-7
eBook Packages: EngineeringEngineering (R0)