Abstract

An intraluminal coronary stent is a metal scaffold deployed in a stenotic artery during Percutaneous Coronary Intervention (PCI). Intravascular Ultrasound (IVUS) is a catheter-based imaging technique generally used for assessing the correct placement of the stent. All the approaches proposed so far for the stent analysis only focused on the struts detection, while this paper proposes a novel approach to detect the boundaries and the position of the stent along the pullback. The pipeline of the method requires the identification of the stable frames of the sequence and the reliable detection of stent struts. Using this data, a measure of likelihood for a frame to contain a stent is computed. Then, a robust binary representation of the presence of the stent in the pullback is obtained applying an iterative and multi-scale approximation of the signal to symbols using the SAX algorithm. Results obtained comparing the automatic results versus the manual annotation of two observers on 80 IVUS in-vivo sequences shows that the method approaches the inter-observer variability scores.

S. Balocco and F. Ciompi equally contributed to the paper.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Ciompi, F., Balocco, S., Rigla, J., Carrillo, X., Mauri, J., Radeva, P.: Computer-aided detection of intra-coronary stent in intravascular ultrasound sequences 43(10), 5616–5625 (2016)

    Google Scholar 

  2. Canero, C., Pujol, O., Radeva, P., Toledo, R., Saludes, J., Gil, D., Villanueva, J., Mauri, J., Garcia, B., Gomez, J.: Optimal stent implantation: three-dimensional evaluation of the mutual position of stent and vessel via intracoronary echocardiography. In: Computers in Cardiology, pp. 261–264 (1999)

    Google Scholar 

  3. Dijkstra, J., Koning, G., Tuinenburg, J., Oemrawsingh, P., Reiber, J.: Automatic border detection in intravascular iltrasound images for quantitative measurements of the vessel, lumen and stent parameters. In: Computers in Cardiology 2001, vol. 28 (Cat. No. 01CH37287), vol. 1230, pp. 25–28 (2001)

    Google Scholar 

  4. Dijkstra, J., Koning, G., Tuinenburg, J.C., Oemrawsingh, P.V., Reiber, J.H.: Automatic stent border detection in intravascular ultrasound images. In: International Congress Series, vol. 1256, pp. 1111–1116. Elsevier (2003)

    Google Scholar 

  5. Rotger, D., Radeva, P., Bruining, N.: Automatic detection of bioabsorbable coronary stents in ivus images using a cascade of classifiers. IEEE Trans. Inform. Technol. Biomed. 14, 535–537 (2010)

    Article  Google Scholar 

  6. Gatta, C., Balocco, S., Ciompi, F., Hemetsberger, R., Leor, O.R., Radeva, P.: Real-time gating of IVUS sequences based on motion blur analysis: method and quantitative validation. In: Jiang, T., Navab, N., Pluim, J.P.W., Viergever, M.A. (eds.) MICCAI 2010. LNCS, vol. 6362, pp. 59–67. Springer, Heidelberg (2010). doi:10.1007/978-3-642-15745-5_8

    Chapter  Google Scholar 

  7. Lin, J., Keogh, E., Wei, L., Lonardi, S.: Experiencing sax: a novel symbolic representation of time series. Data Min. Knowl. Disc. 15, 107 (2007)

    Article  MathSciNet  Google Scholar 

  8. Ciompi, F., Pujol, O., Gatta, C., Alberti, M., Balocco, S., Carrillo, X., Mauri-Ferre, J., Radeva, P.: Holimab: a holistic approach for media-adventitia border detection in intravascular ultrasounds. Med. Image Anal. 16, 1085–1100 (2012)

    Article  Google Scholar 

Download references

Acknowledgements

This work was supported in part by the MICINN Grant TIN2015-66951-C2-1-R, SGR 1219, CERCA and ICREA Academia’2014.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Simone Balocco .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2017 Springer International Publishing AG

About this paper

Cite this paper

Balocco, S., Ciompi, F., Rigla, J., Carrillo, X., Mauri, J., Radeva, P. (2017). Intra-coronary Stent Localization in Intravascular Ultrasound Sequences, A Preliminary Study. In: Cardoso, M., et al. Intravascular Imaging and Computer Assisted Stenting, and Large-Scale Annotation of Biomedical Data and Expert Label Synthesis. LABELS STENT CVII 2017 2017 2017. Lecture Notes in Computer Science(), vol 10552. Springer, Cham. https://doi.org/10.1007/978-3-319-67534-3_2

Download citation

  • DOI: https://doi.org/10.1007/978-3-319-67534-3_2

  • Published:

  • Publisher Name: Springer, Cham

  • Print ISBN: 978-3-319-67533-6

  • Online ISBN: 978-3-319-67534-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics