Abstract
Continuous and non-invasive measurement of blood pressure (BP) is of great importance. To achieve continuous and cuffless BP monitoring, pulse transit time (PTT) has been reported as a potential parameter. Nevertheless, this approach remains very sensitive, cumbersome and disagreeable for patients. This study proposes a new parameter available in phonocardiogram (PCG) to measure blood pressure. The PCG is processed and analyzed in order to measure the systolic and diastolic durations in order to study their correlation with an estimated PTT. The proposed approach evaluated on a developed data base of 37 subjects shows linear regression of two classes in distribution of diastolic duration with PTT estimated. Where, a good correlation coefficient is found for each class (class1: R = 0.87, class2: R = 0.85. This technic has significant potential to develop a new approach to measure blood pressure using PCG signal.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Bartels, A., Harder, D.: Non-invasive determination of systolic blood pressure by heart sound pattern analysis. Clin. Phys. Physiol. Meas. 13(3), 249 (1992)
Nigam, V., Priemer, R.: Simplicity based gating of heart sounds. In: 2005 48th Midwest Symposium on Circuits and Systems, pp. 1298–1301. IEEE (2005)
Obrist, P.A., Light, K.C., McCubbin, J.A., Hutcheson, J.S., Hoffer, J.L.: Pulse transit time: relationship to blood pressure. Behav. Res. Methods 10(5), 623–626 (1978)
Omari, T., Bereksi-Reguig, F.: An automatic wavelet denoising scheme for heart sounds. Int. J. Wavelets Multiresolut. Inf. Process. 13(03), 1550016 (2015)
Perloff, D., Sokolow, M., Cowan, R.: The prognostic value of ambulatory blood pressures. JAMA 249(20), 2792–2798 (1983)
Sakamoto, T., Kusukawa, R., Maccanon, D.M., Luisada, A.A., Harvey, I.: Hemodynamic determinants of the amplitude of the first heart sound. Circ. Res. 16(1), 45–57 (1965)
Shukla, S.N., Kakwani, K., Patra, A., Lahkar, B.K., Gupta, V.K., Jayakrishna, A., Vashisht, P., Sreekanth, I.: Noninvasive cuffless blood pressure measurement by vascular transit time. In: 2015 28th International Conference on VLSI Design (VLSID), pp. 535–540. IEEE (2015)
Winter, D.A.: Biomechanics and Motor Control of Human Movement. Wiley, Hoboken (2009)
Yang, X.-L., Hu, W., Yan, H., Xiao, M., Sun, X.: Research progress of noninvasive continuous blood pressure measurements based on pulse wave velocity. Hangtian Yixue yu Yixue Gongcheng 24(6), 467–472 (2011)
Zhang, X.-Y., Zhang, Y.-T.: Model-based analysis of effects of systolic blood pressure on frequency characteristics of the second heart sound. In: 2006 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2006, pp. 2888–2891. IEEE (2006)
Acknowledgement
This research was partially supported by Boumerdes university-Algeria. We thank our colleagues from both Tlemcen university and boumerdes university who provided insight and expertise that greatly assisted the research, although they may not agree with all of the conclusions of this paper.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG, part of Springer Nature
About this paper
Cite this paper
Tahar, O., Nadia, O., Redouane, B., Nabil, D., Fethi, BR. (2018). New Parameter Available in Phonocardiogram for Blood Pressure Estimation. In: Rojas, I., Ortuño, F. (eds) Bioinformatics and Biomedical Engineering. IWBBIO 2018. Lecture Notes in Computer Science(), vol 10814. Springer, Cham. https://doi.org/10.1007/978-3-319-78759-6_28
Download citation
DOI: https://doi.org/10.1007/978-3-319-78759-6_28
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-78758-9
Online ISBN: 978-3-319-78759-6
eBook Packages: Computer ScienceComputer Science (R0)