Abstract
Image registration is relevant for many medical procedures. For CT-guided ablation procedures, integrating the lesion location from diagnostic contrast-enhanced CT (CECT) images in interventional CT images may provide better guidance for the interventional radiologist. The main requirement for such methods is to accurately align the lesion location. This, in general, can not be measured, and often surrogates are used for the assessment. In this work, we present a method that permits the assessment of the accuracy of the lesion localization, i.e. assessing the value that is relevant for clinical practice. To this end, we developed a method that virtually removes the contrast agent from an interventional CT image, use this image for the registration, and use the original CECT image for the assessment. For the experimental evaluation, imaging data of 20 subjects (33 lesions) were used, and the registration accuracy of a publicly available registration method was assessed using this method.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Fischer, B., Modersitzki, J.: Ill-posed medicine-an introduction to image registration. Inverse Prob. 24, 034008 (2008)
Rohlfing, T.: Image similarity and tissue overlaps as surrogates for image registration accuracy: widely used but unreliable. IEEE Trans. Med. Imaging. 31(2), 153–163 (2012)
Luu, H.M., Klink, C., Niessen, W., Moelker, A., van Walsum, T.: An automatic registration method for pre- and post-interventional CT images for assessing treatment success in liver RFA treatment. Med. Phys. 42(9), 5559–5567 (2015)
Luu, H.M., Klink, C., Niessen, W., Moelker, A., Walsum, T.V.: Non-rigid registration of liver CT images for CT-guided ablation of liver tumors. PLOS ONE 11(9), e0161600 (2016)
Laura, C., Drechsler, K., Wesarg, S., Bale, R.: Accurate physics-based registration for the outcome validation of minimal invasive interventions and open liver surgeries. IEEE Trans. Biomed. Eng. PP(99), 1 (2016)
Rieder, C., Wirtz, S., Strehlow, J., Zidowitz, S., Bruners, P., Isfort, P., Mahnken, A.H., Peitgen, H.O.: Automatic alignment of pre- and post-interventional liver CT images for assessment of radiofrequency ablation, vol. 8316, pp. 83163E–83163E-8 (2012)
Wang, B., Ying, C.A.O.: Liver medical image registration based on biomechanical model. Multimed. Tools Appl. 76, 1–18 (2016)
Nielsen, M.S., Østergaard, L.R., Carl, J.: A new method to validate thoracic CT-CT deformable image registration using auto-segmented 3D anatomical landmarks. Acta Oncol. 54(9), 1515–1520 (2015)
Nie, K., Chuang, C., Kirby, N., Braunstein, S., Pouliot, J.: Site-specific deformable imaging registration algorithm selection using patient-based simulated deformations. Med. Phys. 40(4), 041911 (2013)
Klein, S., Staring, M., Murphy, K., Viergever, M., Pluim, J.P.W.: Elastix: a toolbox for intensity-based medical image registration. IEEE Trans. Med. Imaging 29(1), 196–205 (2010)
Acknowledgements
Theo van Walsum was supported by ITEA project 13031: Benefit.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2018 Springer International Publishing AG, part of Springer Nature
About this paper
Cite this paper
Luu, M.H., Boulkhrif, H., Moelker, A., van Walsum, T. (2018). Registration Evaluation by De-enhancing CT Images. In: Klein, S., Staring, M., Durrleman, S., Sommer, S. (eds) Biomedical Image Registration. WBIR 2018. Lecture Notes in Computer Science(), vol 10883. Springer, Cham. https://doi.org/10.1007/978-3-319-92258-4_8
Download citation
DOI: https://doi.org/10.1007/978-3-319-92258-4_8
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-319-92257-7
Online ISBN: 978-3-319-92258-4
eBook Packages: Computer ScienceComputer Science (R0)