Comparative Technical Study of Two Generations of CR Plates for Digital Mammography

  • Conference paper
Digital Mammography (IWDM 2008)

Part of the book series: Lecture Notes in Computer Science ((LNIP,volume 5116))

Included in the following conference series:

  • 1293 Accesses

Abstract

The performance that can be achieved with CR plates for mammographic applications can be influenced by 2 main components: (1) the performance of plate and reader, and (2) the X-ray beam quality and intensity. Present study investigates a prototype CR plate with a crystal based phosphor layer, as produced by Konica Minolta, in a comparative set-up with a commercially available CR plate of the same company. The following system tests were performed: contrast-detail analysis, system MTF and noise power evaluations. The results reveal that the new CR plate outperforms the older plate. Similar levels of quality can be achieved with a 26% lower dose. The contrast-detail analysis shows better results for the W/Rh anode filter combination than for Mo/Mo and Mo/Rh. Therefore higher beam qualities may be promising candidates for use in clinical practice. It may be recommendable to work in practice at the same dose settings as with the actually available plates and thus benefit from better image quality.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. van Engen, R., et al.: The European protocol for the quality control of the physical and technical aspects of mammography screening. Part B In: European Guidelines for Breast Cancer Screening, 4th edn. (2006)

    Google Scholar 

  2. Young, K.C., et al.: Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems. In: SPIE, vol. 614206, pp. 1-13 (2006)

    Google Scholar 

  3. Lazzari, B., Gori, C., Rosselli Del Turco, M.: Physical characteristics of five clinical systems for digital mammography. Med. Phys. 34(7), 2730–2743 (2007)

    Article  Google Scholar 

  4. Marshall, N.W.: Early experience in the use of quantitative image quality measurements for the quality assurance of full field digital mammography x-ray systems. Phys. Med. Biol. 52(18), 5545–5568 (2007)

    Article  Google Scholar 

  5. Monnin, P., Gutierrez, D., Bulling, S., Guntern, D., Verdun, F.R.: A comparison of the performance of digital mammography systems. Med. Phys. 34(3), 906–914 (2007)

    Article  Google Scholar 

  6. Ohara, K., et al.: Investigation of basic imaging properties in digital radiography. 13. Effect of simple structured noise on the detectability of simulated stenotic lesions. Med. Phys. 16(1), 14–21 (1989)

    Article  Google Scholar 

  7. Elliot, P.B.: Tables of d’ in Signal Detection and recognition by human observers. In: Swets, J.A. (ed.), Wiley and Sons, Chichester (1964)

    Google Scholar 

  8. Carton, A.K., et al.: Validation of MTF measurement for digital mammography quality control. Med. Phys. 6, 1684–1695 (2005)

    Article  Google Scholar 

  9. Carton, A.: Development and implementation of methods for the assessment of image quality and detector performance for digital mammography. PhD thesis (2004)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Elizabeth A. Krupinski

Rights and permissions

Reprints and permissions

Copyright information

© 2008 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Bosmans, H. et al. (2008). Comparative Technical Study of Two Generations of CR Plates for Digital Mammography. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_100

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-70538-3_100

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-70537-6

  • Online ISBN: 978-3-540-70538-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics