The performance that can be achieved with CR plates for mammographic applications can be influenced by 2 main components: (1) the performance of plate and reader, and (2) the X-ray beam quality and intensity. Present study investigates a prototype CR plate with a crystal based phosphor layer, as produced by Konica Minolta, in a comparative set-up with a commercially available CR plate of the same company. The following system tests were performed: contrast-detail analysis, system MTF and noise power evaluations. The results reveal that the new CR plate outperforms the older plate. Similar levels of quality can be achieved with a 26% lower dose. The contrast-detail analysis shows better results for the W/Rh anode filter combination than for Mo/Mo and Mo/Rh. Therefore higher beam qualities may be promising candidates for use in clinical practice. It may be recommendable to work in practice at the same dose settings as with the actually available plates and thus benefit from better image quality.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
van Engen, R., et al.: The European protocol for the quality control of the physical and technical aspects of mammography screening. Part B In: European Guidelines for Breast Cancer Screening, 4th edn. (2006)
Young, K.C., et al.: Comparison of software and human observers in reading images of the CDMAM test object to assess digital mammography systems. In: SPIE, vol. 614206, pp. 1-13 (2006)
Lazzari, B., Gori, C., Rosselli Del Turco, M.: Physical characteristics of five clinical systems for digital mammography. Med. Phys. 34(7), 2730–2743 (2007)
Marshall, N.W.: Early experience in the use of quantitative image quality measurements for the quality assurance of full field digital mammography x-ray systems. Phys. Med. Biol. 52(18), 5545–5568 (2007)
Monnin, P., Gutierrez, D., Bulling, S., Guntern, D., Verdun, F.R.: A comparison of the performance of digital mammography systems. Med. Phys. 34(3), 906–914 (2007)
Ohara, K., et al.: Investigation of basic imaging properties in digital radiography. 13. Effect of simple structured noise on the detectability of simulated stenotic lesions. Med. Phys. 16(1), 14–21 (1989)
Elliot, P.B.: Tables of d’ in Signal Detection and recognition by human observers. In: Swets, J.A. (ed.), Wiley and Sons, Chichester (1964)
Carton, A.K., et al.: Validation of MTF measurement for digital mammography quality control. Med. Phys. 6, 1684–1695 (2005)
Carton, A.: Development and implementation of methods for the assessment of image quality and detector performance for digital mammography. PhD thesis (2004)
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Bosmans, H. et al. (2008). Comparative Technical Study of Two Generations of CR Plates for Digital Mammography. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_100
Download citation
DOI: https://doi.org/10.1007/978-3-540-70538-3_100
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-70537-6
Online ISBN: 978-3-540-70538-3
eBook Packages: Computer ScienceComputer Science (R0)