High breast tissue density has been shown to be one of the strongest predictors of breast cancer risk in women; though currently there are no calibrated methods to ensure that clinical measures of density are accurate. This inability to make accurate measurements impedes the use of breast tissue density as a cancer risk indicator. An accurate and precise method to measure the volumetric density of breast tissue in a clinical environment has been developed without modifying existing methods. The single x-ray absorptiometry (SXA) approach is validated against known breast fibroglandular density test phantoms and the accuracy and precision of the measure is monitored longitudinally. With cross-calibration and longitudinal quality control using the same test phantoms we show that SXA density measures are comparable between seven Hologic Selenia Full-Field Digital Mammography systems. In the future, we plan to address whether SXA measures can be generalized across different makes and models.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Boyd, N.F., Byng, J.W., Jong, R.A., Fishell, E.K., Little, L.E., Miller, A.B., Lockwood, G.A., Tritchler, D.L., Yaffe, M.J.: Quantitative Classification of Mammographic Densities and Breast Cancer Risk: Results From the Canadian National Breast Screening Study. J. Natl. Cancer Inst. 87(9), 670–675 (1995)
Malkov, S., Wang, J., Shepherd, J.A.: Novel Single X-Ray Absorptiometry Method to Solve for Volumetric Breast Density in Mammograms with Paddle Tilt. In: Proceedings of SPIE, vol. 6510, p. 651035 (2007)
Shepherd, J.A., Herve, L., Landau, J., Fan, B., Kerlikowske, K., Cummings, S.R.: Novel Use of Single X-Ray Absorptiometry for Measuring Breast Density. Technol. Cancer Res. Treat. 4(2), 173–182 (2005)
Lu, Y., Mathur, A.K., Blunt, B.A., Gluer, C.C., Will, A.S., Fuerst, T.P., Jergas, M.D., An-driano, K.N., Cummings, S.R., Genant, H.K.: Dual X-ray Absorptiometry Quality Control: Comparison of Visual Examination and Process-Control Charts. Bone Miner Res. 11, 626–637 (1996)
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Wang, J., Malkov, S., Fan, B., Shepherd, J. (2008). Cross-Calibration and Longitudinal Quality Control of Hologic Selenia Full-Field Digital Mammography Systems for Volumetric Breast Density Measurements. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_102
Download citation
DOI: https://doi.org/10.1007/978-3-540-70538-3_102
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-70537-6
Online ISBN: 978-3-540-70538-3
eBook Packages: Computer ScienceComputer Science (R0)