Abstract
Digital Breast Tomosynthesis (DBT) Mammography is an emerging technique that has the potential to improve breast cancer detection. In DBT, low-dose mammograms are acquired at a number of projection angles over a limited range and the 3D breast volume is reconstructed. In this study, we investigated the effect of different distributions of projection-view (PV) images that included different angular range and angular spacing on the reconstruction image quality. A GE prototype DBT system was used to acquire a total of 21 PVs in 3º increments over a ±30º range, from which multiple subsets containing the same number of 11 PV images were selected. A custom-built breast phantom and a selected patient case were used to evaluate the image quality. For breast phantom study, the contrast-to-noise ratio (CNR), the normalized line profiles of test objects, and an artifact spread function (ASF) were used as performance measures to compare the results for the different subsets and for the full set. The simultaneous algebraic reconstruction technique (SART) was used to reconstruct the DBT under all conditions. Our results demonstrated that large DBT angular range gave superior CNR and ASF for masses and less interplane blurring for high-density objects. Narrow angular range favors in-plane edge sharpness for high-density objects.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Niklason, L.T., Christian, B.T., Niklason, L.E., et al.: Digital tomosynthesis in breast imaging. Radiology 205, 399–406 (1997)
Wu, T., Stewart, A., Stanton, M., et al.: Tomographic mammography using a limited number of low-dose cone-beam projection images. Medical Physics 30, 365–380 (2003)
Kopans, D.: Digital tomosynthesis and other applications, vol. 130. RSNA Program Book (2005)
Helvie, M.A., Roubidoux, M.A., Hadjiiski, L.M., Zhang, Y., Carson, P.L., Chan, H.-P.: Tomosynthesis Mammography vs Conventional Mammography: Comparison of Breast Masses Detection and Characterization, vol. 381. RSNA Program Book (2007)
Eberhard, J.W., Staudinger, P., Smolenski, J., et al.: High speed, large angle mammography tomosynthesis system. In: Proc. SPIE, vol. 6142, p. 61420C (2006)
Zhang, Y., Chan, H.-P., Sahiner, B., et al.: A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis. Medical Physics 33, 3781–3795 (2006)
Andersen, A.H., Kak, A.C.: Simultaneous algebraic reconstruction technique (SART): a new implementation of the ART algorithm. Ultrason. Imaging 6, 81–94 (1984)
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 2008 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Zhang, Y., Chan, HP., Goodsitt, M.M., Schmitz, A., Eberhard, J.W., Claus, B.E.H. (2008). Investigation of Different PV Distributions in Digital Breast Tomosynthesis (DBT) Mammography. In: Krupinski, E.A. (eds) Digital Mammography. IWDM 2008. Lecture Notes in Computer Science, vol 5116. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70538-3_82
Download citation
DOI: https://doi.org/10.1007/978-3-540-70538-3_82
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-70537-6
Online ISBN: 978-3-540-70538-3
eBook Packages: Computer ScienceComputer Science (R0)