Evaluation of a new, wireless pulse oximetry monitoring system in infants: the BBA bootee

  • Conference paper
4th International Workshop on Wearable and Implantable Body Sensor Networks (BSN 2007)

Abstract

A new system for wireless monitoring of pulse oximetry (SpO2) was developed on the basis of a Nonin OEM III oximetry module and a radiofrequency transceiver. The electronic unit and the power supply was integrated into a specially designed infant shoe named BBA bootee. Clinical evaluation of the system revealed a good agreement between the pulse oximetry data transmitted by the BBA bootee and those recorded simultaneously by a reference monitor. The comparative data collected in 39 babies yielded a mean (bias SD) value of (−1.1 1.9)% for SpO2 and (−2 8) beats per minute for heart rate. Use of an integrated accelerometer/actimeter to reduce the motion artifact is addressed as well as ergonomics of the sensor-supporting garment.

The research which enabled development of the BBA bootee and its evaluation in a hospital setting was funded by the Fondation ANAÏS DUMANOIS, working under the aegis of the Fondation de France.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. National Institutes of Health Consensus Development Conference on Infantile Apnea and Home Monitoring, Sept 29 to Oct 1, 1986, Pediatrics, 1987, vol.79, pp. 292–299.

    Google Scholar 

  2. “Committee on Fetus and Newborn. American Academy of Pediatrics. Apnea, sudden infant death syndrome, and home monitoring”, Pediatrics, 2003, vol.111, pp. 914–917.

    Google Scholar 

  3. M.R. Neuman, H. Watson, R.S. Mendenhall, J.T. Zoldak, J.M. Di Fiore, M. Peucker, T.M. Baird, D.H. Crowell, T.T. Hoppenbrouwers, D. Hufford, C.E. Hunt, M.J. Corwin, L.R. Tinsley, D.E. Weese-Mayer, M.A. Sackner, Collaborative Home Infant Monitor Evaluation (CHIME) Study Group, “Cardiopulmonary monitoring at home: the CHIME monitor,” Physiol Meas., 2001, vol. 22, no. 2, pp. 267–286.

    Article  Google Scholar 

  4. “The Collaborative Home Infant Monitoring Evaluation,” Arch. Pediatr. Adolesc. Med., 2005, vol.159, pp.18–24.

    Google Scholar 

  5. A.F. Aly. D. Afchine, P. Esser, M. Joos, H.J. Niewerth, A. Wiater, M. Meier, D. Padeken, A. Pericas, D. Schwartmann, T. Weber, V. Wendrix, M. Wirtz, “Telemetry as a new concept in long term monitoring of SIDS-risk infant”, Eur. J. Med. Res., 2000, vol. 5, no. 1, pp.19–22.

    Google Scholar 

  6. V. Gramse, A. De Groote, M. Paiva, “Novel concept for a Noninvasive cardiopulmonary monitor for infants: a pair of pajamas with an integrated sensor module,” Ann. Biomed. Eng., 2003, vol. 31, no. 2, pp.152–158.

    Article  Google Scholar 

  7. M. Catrysse, R. Puers, C. Hertleer, L. Van Langenhove, H. van Egmond, D. Matthys, “Towards the integration of textile sensors in a wireless monitoring suit,” Sensors and Actuators A, 2004, vol. 114, no. 2–3, pp. 302–311.

    Article  Google Scholar 

  8. J.M. Bland, D.G. Altman, “Statistical methods for assessing agreement between two methods of clinical measurement,” Lancet, 1986, vol 1, pp.307–310.

    Google Scholar 

  9. P. Leonard, T.F. Beattie, P.S. Addison, J.N. Watson, “Wavelet analysis of pulse oximeter waveform permits identification of unwell children,” Emerg. Med. J., 2004, vol. 21, no. 1, pp. 59–60.

    Article  Google Scholar 

  10. A. Kahn, “European Society for the Study and Prevention of Infant Death. Recommended clinical evaluation of infants with an apparent life-threatening event. Consensus document of the European Society for the Study and Prevention of Infant Death 2003,” Eur. J. Pediatr., 2004, vol. 163, no. 2, pp. 108–115.

    Article  Google Scholar 

  11. S. Espagne, I. Hamon, O. Thiébaugeorges, J.-M. Hascoet, “Sudden death of neonates in the delivery room,” Arch. De pédiatrie, 2004, vol. 11, pp. 436–439.

    Article  Google Scholar 

  12. H. Gatti, C. Castel, P. Andrini, P. Durand, C. Carlus, J.L. Chabernaud, M. Vial, M. Dehan, C. Boithias, “Cardiorespiratory arrest in full term newborn infants: six case reports,” Arch. De pédiatrie, 2004, vol. 11, pp. 432–435.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Larissa I. Netchiporouk .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2007 International Federation for Medical and Biological Engineering

About this paper

Cite this paper

Rimet, Y. et al. (2007). Evaluation of a new, wireless pulse oximetry monitoring system in infants: the BBA bootee. In: Leonhardt, S., Falck, T., Mähönen, P. (eds) 4th International Workshop on Wearable and Implantable Body Sensor Networks (BSN 2007). IFMBE Proceedings, vol 13. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-70994-7_25

Download citation

  • DOI: https://doi.org/10.1007/978-3-540-70994-7_25

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-540-70993-0

  • Online ISBN: 978-3-540-70994-7

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics