Abstract
The author has involved in two types of clinically available artificial hearts in Japan for these 30 years. Firstly, Toyobo auxiliary pulsatile ventricular assist pump was commercialized in 1991 and over 700 clinical cases are reported in Japanese market. Secondly, an implantable non-pulsatile ventricular assist pump (EVAHEART, Sunmedical Tech. Res. Co.) has been implanted into 11 patients in Japan. The author has been establishing a methodology to eliminate considerable risk factors through a development of hydrodynamic performance test, durability test and biocompatibility test. These in vitro tests are all effective to ensure a safety of the system and also in vitro tests have a contribution to reduce a number of animal experiments.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Takano, H., Hayashi, K., Umezu, M., Tomino, T., Koh, Y., Kito, Y., Koyanagi, H., Naito, Y., Fujita, T., Manabe, H.: Fundamental studies of clinically applicable heart assist device: Development of the system for heart assist device. Jpn. J. Artif. Organs 9, 601–603 (1980)
Umezu, M., Takano, H., Hayashi, K., Taenaka, Y., Nakamura, T., Matsuda, T., Akutsu, T.: Development of a control-drive unit for left ventricular assist device. In: Proceedings of Multi-international Instrumental Conference (MICONEX 1983), pp. 759–763 (1983)
Yamazaki, K., Mori, T., et al.: The cool-seal concept: A low temperature mechanical seal with recirculating purge system for blood pumps. In: Kobayashi, H., Akutsu, T. (eds.) Artificial Heart, Tokyo, Japan, vol. 6, pp. 339–344. Springer, Heidelberg (1994)
Umezu, M., Yamazaki, K., Yamazaki, S., Iwasaki, K., Miyakoshi, T., Kitano, T., Tokuno, T.: Japanese-made implantable centrifugal type ventricular assist system (LVAS): EVAHEART. Biocybernetics and Biomedical Engineering 27(1/2), 111–119 (2007)
Registry of artificial organs-2000: The Japanese J Artif. Organs (in Japanese) 30, 46–53 (2000)
Kitano, T., Tokuno, T., Kaneko, K., Yamazaki, K., Kihara, S., Umezu, M., Iwasaki, K., Conti, J.C.: A new and more practical approach for in vitro durability test for rotary LVAS pump. ASIO J 50(2), 133 (2004)
Iwasaki, K., Umezu, M., Tsujimoto, T., Saeki, W., Inoue, A., Nakazawa, T., Arita, M., Ye, C.X., Imachi, K., Ishihara, K., Tanaka, T.: A challenge to develop an inexpensive ’Spiral vortex pump’. In: 2nd Waseda-Renji Hospital BioMedical Engineering Symposium, Shanghai, China, pp. 8–10 (2002)
Umezu, M., Ye, C.X., Nugent, A., Nakamura, T., Iwasaki, K., Arita, M., Shiraishi, Y., Tanaka, T., Imachi, K., Ishihara, K., Chang, V.P.: Spiral vortex ventricular assist device: Its history and present status. In: 2nd Waseda-Renji Hospital BioMedical Engineering Symposium, Shanghai, China, pp. 6–7 (2002)
Ishihara, K., Tsuji, T., Kurosaki, T., Nakabayashi, N.: Hemocompatibility on graft copolymers of poly (2-methacryloyloxyethyl phosphorylcholine) side chain and poly (n-butyl methacrylate) backbone. Journal of Biomedical Materials Research 28, 225–232 (1994)
Author information
Authors and Affiliations
Editor information
Rights and permissions
Copyright information
© 2007 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Umezu, M. (2007). How to Ensure Safety Factors in the Development of Artificial Heart: Verified by the Usage of ”Modeling and Simulation” Technology. In: Li, K., Li, X., Irwin, G.W., He, G. (eds) Life System Modeling and Simulation. LSMS 2007. Lecture Notes in Computer Science(), vol 4689. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-540-74771-0_10
Download citation
DOI: https://doi.org/10.1007/978-3-540-74771-0_10
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-540-74770-3
Online ISBN: 978-3-540-74771-0
eBook Packages: Computer ScienceComputer Science (R0)