Skip to main content

Mobile Visual Analytics for Datacenter Power and Cooling Management

  • Conference paper
  • 951 Accesses

Abstract

The demand for data center solutions with lower total cost of ownership and lower complexity of management is driving the creation of next generation datacenters. The information technology industry is in the midst of a transformation to lower the cost of operation through consolidation and better utilization of critical data center resources. Successful consolidation necessitates increasing utilization of capital intensive “always-on” data center infrastructure, reduction in the recurring cost of power and management of physical resources. In this paper, we describe a tool that allows the data center facility managers and administrators to view and analyze the Key Performance Indicators (KPIs) associated with their data centers using pixel cell-based [10,11] visual analytics. The basic idea of our technique is to use the smallest element in the display to present the detailed information of the poser and thermal data records. Administrators can quickly recognize the patterns, trends, and anomalies. Furthermore, we discuss case studies of mobile visual analytics for energy and thermal state monitoring utilizing data from a rich sensor network.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. The Uptime Institute, Heat density trends in Data Processing, Computer systems and Telecommunications Equipment, White Paper issued by The Uptime Institute (2000)

    Google Scholar 

  2. Sharma, R.K., Shih, R., Bash, C.E., Patel, C.D., Varghese, P., Mekanapurath, M., Velayudhan, S., Kumar, M.V.: On building Next Generation Data Centers. In: Proceedings of Compute 2008, Bangalore, Karnataka, India, January 18-20 (2008)

    Google Scholar 

  3. Hao, M., Dayal, U., Keim, D.A., Schreck, T.: Multi-Resolution Techniques for Visual Exploration of Large Time-Series Data. In: Proceedings of IEEE VGTC Symposium on Visualization, EuroVis 2007 (2007)

    Google Scholar 

  4. Hao, M., Dayal, U., Keim, D.A., Morent, D., Schneidewind, J.: Intelligent Visual Analytics Queries. In: IEEE Symposium on Visual Analytics Science and Technology, CA (2007)

    Google Scholar 

  5. Sharma, S., Patel, S.: Application of exploratory data analysis techniques to temperature data in a conventional datacenter. In: Proc. ASME IPACK 2007, IPACK 2007-33170, BC, Canada (July 2007)

    Google Scholar 

  6. Patel, et al.: Energy flow in the information technology Stack: Introducing the coefficient of performance of the ensemble. In: Proc. ASME Intl. Mech. Eng. Cong. Exp. (IMECE), IMECE 2006-14830

    Google Scholar 

  7. Bash, C.E., Patel, S.: Dynamic Thermal Management of Air-Cooled Datacenters. In: ASME/IEEE ITherm 2006, San Diego, CA (2006)

    Google Scholar 

  8. Marwah, M., Sharma, R.K., Shih, R., Patel, C.D., Bhatia, V., Mekanapurath, M., Velumani, R., Velayudhan, S.: Data analysis, Visualization and Knowledge Discovery in Sustainable Data Centers. In: Proceedings of Compute 2009, Bangalore, Karnataka, India, January 9-10 (2009)

    Google Scholar 

  9. Bash, C.E., Forman, G.: Cool Job Allocation: Measuring the Power Savings of Placing Jobs at Cooling-Efficient Locations in the Data Center, USENIX, San Jose, CA (June 2007)

    Google Scholar 

  10. Hao, M., Sharmal, R.K., Dayal, U., Keim, D.A., Vennelakanti, R.: Application of Visual Analytics For Thermal State Management in Large Data Centers. CGF Journal (2009)

    Google Scholar 

  11. Hao, M., Keim, D.A., Dayal, U., Oelke, D., Tremblay, C.: Density Displays for Data Stream Monitoring. In: IEEE EuroVis 2008 (2008)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 ICST Institute for Computer Science, Social Informatics and Telecommunications Engineering

About this paper

Cite this paper

Sharma, R. et al. (2010). Mobile Visual Analytics for Datacenter Power and Cooling Management. In: Phan, T., Montanari, R., Zerfos, P. (eds) Mobile Computing, Applications, and Services. MobiCASE 2009. Lecture Notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering, vol 35. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-12607-9_11

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-12607-9_11

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-12606-2

  • Online ISBN: 978-3-642-12607-9

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics