Abstract
IEC61850 communication standard for digital substation automation creates a new way to think about conventional protection scheme and configuration of substation. The presence of communication link in process bus makes a revolutionary change for future digital substation. This paper discusses briefly about process bus architecture and presents a new approach of thinking in busbar structure to make the bus protection less sensitive with communication link performance degradation. IEC61850-9-2LE implementation is analyzed and process bus based on Ethernet technology is considered. Transient element based conventional bus differential protection is used with split busbar configuration and finally demonstrates the reliability and feasibility of proposed technique for digital substation.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Liu, K., Dong, X.Z., Bo, Z.Q.: Study on Non-Conventional Instrument Transformer and IEC61850 Impact of Current Differential Protection. In: Transmission and Distribution Conference and Exposition: Latin America, IEEE/PES, August 13-15(2008)
Zou, G.B., Gao, H.L., Wang, X.G.: A Novel Distributed Busbar Protection For Digital. In: Asia-Pacific Power and Energy Engineering Conference (APPEEC), March 28-31 (2010)
Apostolov, A.P.: IEC61850 based Bus Protection-principle and Application. In: IEEE Power & Energy Society General Metting, PES 2009, Calgary, Alberta, July 26-30 (2009)
Xyngi, I., Popov, M.: Integrated Busbar Protection Scheme Based On IEC61850-9-2 Process Bus Concept. In: IEEE Power and Energy Society General Meeting, July 25-29 (2010)
Implementation Guideline for Digital Interface to Instrumental Transformer Using IEC61850-9-2, UCA International User Group (2010)
Mahmood, Q.I.A., Mahmood, B.S.: Enhancement of Industrial Ethernet Performance using multicast or VLAN technique. In: Information and Communication Technologies: From Theory to Applications, ICTTA, April 7-11 (2008)
Watanabe, H., Shunto, I., Lgarashi, K., Beaumont, P., Okuno, K.: A Enhanced Decentralized Numerical Busbar Protection Relay Utilizing Instantaneous Current Values From High Speed Sampling. In: IEEE Conference on Developments in Power System Protection, pp. 133–136 (2001)
IEC61850:Communication network and systems in substation, Part1 9 (2004)
Sidhu, T.S., Gangadharan, P.K.: Control and Automation of Power System Substation Using IEC61850 Communication. In: Proceedings of IEEE Conference on Control Application (2005)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Islam, M., Lee, HH. (2012). A Comprehensive Study on IEC61850 Process Bus Architecture and Spit Bus Based Differential Protection. In: Huang, DS., Gan, Y., Gupta, P., Gromiha, M.M. (eds) Advanced Intelligent Computing Theories and Applications. With Aspects of Artificial Intelligence. ICIC 2011. Lecture Notes in Computer Science(), vol 6839. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-25944-9_41
Download citation
DOI: https://doi.org/10.1007/978-3-642-25944-9_41
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-25943-2
Online ISBN: 978-3-642-25944-9
eBook Packages: Computer ScienceComputer Science (R0)