Skip to main content

Research into the Possibility to Use Impedance Rheocardiography in a Non-invasive Assessment of Haemodynamic Condition of Patients with Heart Diseases

  • Conference paper
Information Technologies in Biomedicine

Part of the book series: Lecture Notes in Computer Science ((LNBI,volume 7339))

  • 2300 Accesses

Abstract

Impedance rheocardiography is a non-invasive method of the haemodynamic condition of patients which bases on the measurement of the electrical impedance of the chest caused by the flow of blood. The method has been more and more popular in clinics in the recent years due to its being non-invasive and its possibility to monitor patients continuously, even those in critical condition. Impedance rheocardiography is treated as a complement to echocardiography or invasive monitoring. A possibility is also seen for its application in the detection of fluid in the intra-chest cavity. The study attempts to assess the clinical application of this method in haemodynamic examinations of patients with acute left ventricular failure. The tests were carried out on a group of 45 patients with heart failure in the course of dilated cardiomyopathy (DCM). A statistically significant correlation has been revealed between the results of cardiac index (CI) and stroke volume index (SI) measurement made with the method of impedance rheocardiography and the invasive reference method, (pulmonary artery catheterization – PAC), and between the basis impedance value Z 0 and the properties of fluid present in the thoracic cavity, stated in physical test.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Balestra, B., et al.: Esophageal electrodes allow precise assessment of cardiac output by bioimpedance. Crit. Care Med. 20, 62–67 (1992)

    Article  PubMed  CAS  Google Scholar 

  2. Barry, B.N., et al.: Lack of agreement between bioimpedance and continuous thermodilution measurement of cardiac output in intensive care unit patients. Critical Care 1 (1997)

    Google Scholar 

  3. Berman, J.R., et al.: Transthoracic electrical impedance as a guide to intravascular overload. Arch. Surg. 102, 61 (1971)

    Article  PubMed  CAS  Google Scholar 

  4. Denniston, J.C., Baker, L.E.: Measurement of pleural effusion by electrical impedance. J. Appl. Physiol. 38, 851 (1975)

    PubMed  CAS  Google Scholar 

  5. Gawlikowski, M., Pustelny, T., Przywara-Chowaniec, B., Nowak-Gawlikowska, J.: Model study of cardiac output measurement by thermodilution in thermal instability. Acta Physica Polonica A 118, 1124–1126 (2010)

    CAS  Google Scholar 

  6. Gawlikowski, M., Pustelny, T.: Theoretical and model analysis of the unreliability of cardiac output measurement by means of the thermodilution method. Bulletin of the Polish Academy of Science 59(4), 435–439 (2011)

    Article  Google Scholar 

  7. Godie, O., Friedl, L., Hannekum, A.: Accuracy of beat-to-beat cardiac output monitoring by pulse contour analysis in hemodynamical unstable patients, vol. 6, p. 7 (2001)

    Google Scholar 

  8. Huang, K.C., et al.: Stroke volume measurements by electrical bioimpedance and echocardiography in healthy volunteers. Crit. Care Med. 18, 1274 (1990)

    Article  PubMed  CAS  Google Scholar 

  9. Jewkes, C., et al.: Non-invasive measurement of cardiac output by thoracic electrical bioimpedance: a study of reproducibility and comparison with thermodilution. Br. J. Anaesth. 67, 788–794 (1991)

    Article  PubMed  CAS  Google Scholar 

  10. Jewkins, C., Verhoeff, F.: Noninvasive cardiac output measurement by bioimpedance: is it reliable? Br. J. Anaesth. 63, 619 (1989)

    Google Scholar 

  11. Klimczak, K.: Clinical Echocardiography. Elselvier Urban&Partner, Wroclaw (2008) (in Polish)

    Google Scholar 

  12. Kubicek, W.G., et al.: Development and evaluation of an impedance cardiac output system. Aerospace Med. 37, 1208–1212 (1966)

    PubMed  CAS  Google Scholar 

  13. Lichtental, P.R.: Cardiopulmonary Care. Edwards Lifescience (2002)

    Google Scholar 

  14. Mehlsen, J., et al.: Reliability of impedance cardiography in measuring central hemodynamics. Clin. Physiol. 11, 579–588 (1991)

    Article  PubMed  CAS  Google Scholar 

  15. Miller, J.C., Horvath, S.M.: Impedance cardiography. Physophysiology 15, 80–91 (1987)

    Article  Google Scholar 

  16. Nieminen, N.S.: Diagnosis and treatment of acute heart insufficiency. The Guideline of European Society of Cardiology. The Polish Cardiology 2, 63 (2005) (in Polish)

    Google Scholar 

  17. Nishikawa, T., Doshi, S.: Errors in the measurement of cardiac output by thermodilution. Canadian Journal of Anesthesia 40(2), 142–153 (1993)

    Article  PubMed  CAS  Google Scholar 

  18. Pawlicki, G.: The fundamentals of biomedical engineering, p. 178. Warsaw University of Technology Publishers (1997) (in Polish)

    Google Scholar 

  19. Payen, D., Gayat, E.: Which general intensive care unit patients can benefit from placement of the pulmonary artery catheter? Critical Care 10(suppl. 3), 7 (2006)

    Article  Google Scholar 

  20. Peyton, P., Thompson, B.: Agreement of an Inert Gas Rebreathing Device with Thermodilution and the Direct Oxygen Fick Method in Measurement of Pulmonary Blood Flow. Journal of Clinical Monitoring and Computing 5-6(18), 0373–0378 (2005)

    Google Scholar 

  21. Pomerantz, M., Delgado, P., Eiseman, B.: Clinical evaluation of transthoracic electrical impedance as a guide to intrathoracic fluid volumes. Ann. Surg. 171, 686 (1970)

    Article  PubMed  CAS  Google Scholar 

  22. Przywara-Chowaniec, B.: Usefulness of impedance rheocardiography in assessment of hemodynamic state and results of pharmacotherapy in patients with serious left ventricle diseases. PhD Thesis, Silesian Medical University (1993) (in Polish)

    Google Scholar 

  23. Przywara-Chowaniec, B., Polonski, L., Gawlikowski, M., Pustelny, T.: Evaluation of impedance rheocardiography suitability in hemodynamic monitoring of patients with serious left ventricle injury. Acta Bio-Optica et Informatica Medica 4(15), 362–364 (2009) (in Polish)

    Google Scholar 

  24. Przywara-Chowaniec, B., Polonski, L., Gawlikowski, M., Pustelny, T.: Clinical studies of rheocardiography application to hemodynamic monitoring of patients with dilated cardiomyopathy. Acta Physica Polonica A 116 (2009)

    Google Scholar 

  25. Quail, A.W., et al.: Thoracic resistivity for stroke volume calculation in impedance cardiology. J. Appl. Physiol. 50, 191 (1981)

    PubMed  CAS  Google Scholar 

  26. Russel, V., Michael, J.R., Warbasse, J.R.: Quantitative evaluation of a non-invasive measure of thoracic fluid volume. Am. Heart J. 1, 83–93 (1973)

    Google Scholar 

  27. Sherwood, A.: Methodological Guidelines for Impedance Cardiography. Psychophysiology 27, 1–23 (1990)

    Article  PubMed  CAS  Google Scholar 

  28. Sodolski, T., Kutarski, A.: Impedance cardiography – method of rapid assessment and monitoring of hemodynamic state. Folia Cardiologica Excerpta 2, 6 (2007) (in Polish)

    Google Scholar 

  29. Szczeklik, A., Tendera, M.: Cardiology. The textbook based on EBM, Cracow, vol. I. Practical Medicine Publishing (2009)

    Google Scholar 

  30. Water, G.A., et al.: Bioelectric impedance. New developments and clinical application. Arch. Surg. 4, 355 (1971)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer-Verlag Berlin Heidelberg

About this paper

Cite this paper

Przywara-Chowaniec, B., Poloński, L., Gawlikowski, M., Pustelny, T. (2012). Research into the Possibility to Use Impedance Rheocardiography in a Non-invasive Assessment of Haemodynamic Condition of Patients with Heart Diseases. In: Piętka, E., Kawa, J. (eds) Information Technologies in Biomedicine. Lecture Notes in Computer Science(), vol 7339. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31196-3_18

Download citation

  • DOI: https://doi.org/10.1007/978-3-642-31196-3_18

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-31195-6

  • Online ISBN: 978-3-642-31196-3

  • eBook Packages: Computer ScienceComputer Science (R0)

Publish with us

Policies and ethics