Abstract
Impedance rheocardiography is a non-invasive method of the haemodynamic condition of patients which bases on the measurement of the electrical impedance of the chest caused by the flow of blood. The method has been more and more popular in clinics in the recent years due to its being non-invasive and its possibility to monitor patients continuously, even those in critical condition. Impedance rheocardiography is treated as a complement to echocardiography or invasive monitoring. A possibility is also seen for its application in the detection of fluid in the intra-chest cavity. The study attempts to assess the clinical application of this method in haemodynamic examinations of patients with acute left ventricular failure. The tests were carried out on a group of 45 patients with heart failure in the course of dilated cardiomyopathy (DCM). A statistically significant correlation has been revealed between the results of cardiac index (CI) and stroke volume index (SI) measurement made with the method of impedance rheocardiography and the invasive reference method, (pulmonary artery catheterization – PAC), and between the basis impedance value Z 0 and the properties of fluid present in the thoracic cavity, stated in physical test.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Balestra, B., et al.: Esophageal electrodes allow precise assessment of cardiac output by bioimpedance. Crit. Care Med. 20, 62–67 (1992)
Barry, B.N., et al.: Lack of agreement between bioimpedance and continuous thermodilution measurement of cardiac output in intensive care unit patients. Critical Care 1 (1997)
Berman, J.R., et al.: Transthoracic electrical impedance as a guide to intravascular overload. Arch. Surg. 102, 61 (1971)
Denniston, J.C., Baker, L.E.: Measurement of pleural effusion by electrical impedance. J. Appl. Physiol. 38, 851 (1975)
Gawlikowski, M., Pustelny, T., Przywara-Chowaniec, B., Nowak-Gawlikowska, J.: Model study of cardiac output measurement by thermodilution in thermal instability. Acta Physica Polonica A 118, 1124–1126 (2010)
Gawlikowski, M., Pustelny, T.: Theoretical and model analysis of the unreliability of cardiac output measurement by means of the thermodilution method. Bulletin of the Polish Academy of Science 59(4), 435–439 (2011)
Godie, O., Friedl, L., Hannekum, A.: Accuracy of beat-to-beat cardiac output monitoring by pulse contour analysis in hemodynamical unstable patients, vol. 6, p. 7 (2001)
Huang, K.C., et al.: Stroke volume measurements by electrical bioimpedance and echocardiography in healthy volunteers. Crit. Care Med. 18, 1274 (1990)
Jewkes, C., et al.: Non-invasive measurement of cardiac output by thoracic electrical bioimpedance: a study of reproducibility and comparison with thermodilution. Br. J. Anaesth. 67, 788–794 (1991)
Jewkins, C., Verhoeff, F.: Noninvasive cardiac output measurement by bioimpedance: is it reliable? Br. J. Anaesth. 63, 619 (1989)
Klimczak, K.: Clinical Echocardiography. Elselvier Urban&Partner, Wroclaw (2008) (in Polish)
Kubicek, W.G., et al.: Development and evaluation of an impedance cardiac output system. Aerospace Med. 37, 1208–1212 (1966)
Lichtental, P.R.: Cardiopulmonary Care. Edwards Lifescience (2002)
Mehlsen, J., et al.: Reliability of impedance cardiography in measuring central hemodynamics. Clin. Physiol. 11, 579–588 (1991)
Miller, J.C., Horvath, S.M.: Impedance cardiography. Physophysiology 15, 80–91 (1987)
Nieminen, N.S.: Diagnosis and treatment of acute heart insufficiency. The Guideline of European Society of Cardiology. The Polish Cardiology 2, 63 (2005) (in Polish)
Nishikawa, T., Doshi, S.: Errors in the measurement of cardiac output by thermodilution. Canadian Journal of Anesthesia 40(2), 142–153 (1993)
Pawlicki, G.: The fundamentals of biomedical engineering, p. 178. Warsaw University of Technology Publishers (1997) (in Polish)
Payen, D., Gayat, E.: Which general intensive care unit patients can benefit from placement of the pulmonary artery catheter? Critical Care 10(suppl. 3), 7 (2006)
Peyton, P., Thompson, B.: Agreement of an Inert Gas Rebreathing Device with Thermodilution and the Direct Oxygen Fick Method in Measurement of Pulmonary Blood Flow. Journal of Clinical Monitoring and Computing 5-6(18), 0373–0378 (2005)
Pomerantz, M., Delgado, P., Eiseman, B.: Clinical evaluation of transthoracic electrical impedance as a guide to intrathoracic fluid volumes. Ann. Surg. 171, 686 (1970)
Przywara-Chowaniec, B.: Usefulness of impedance rheocardiography in assessment of hemodynamic state and results of pharmacotherapy in patients with serious left ventricle diseases. PhD Thesis, Silesian Medical University (1993) (in Polish)
Przywara-Chowaniec, B., Polonski, L., Gawlikowski, M., Pustelny, T.: Evaluation of impedance rheocardiography suitability in hemodynamic monitoring of patients with serious left ventricle injury. Acta Bio-Optica et Informatica Medica 4(15), 362–364 (2009) (in Polish)
Przywara-Chowaniec, B., Polonski, L., Gawlikowski, M., Pustelny, T.: Clinical studies of rheocardiography application to hemodynamic monitoring of patients with dilated cardiomyopathy. Acta Physica Polonica A 116 (2009)
Quail, A.W., et al.: Thoracic resistivity for stroke volume calculation in impedance cardiology. J. Appl. Physiol. 50, 191 (1981)
Russel, V., Michael, J.R., Warbasse, J.R.: Quantitative evaluation of a non-invasive measure of thoracic fluid volume. Am. Heart J. 1, 83–93 (1973)
Sherwood, A.: Methodological Guidelines for Impedance Cardiography. Psychophysiology 27, 1–23 (1990)
Sodolski, T., Kutarski, A.: Impedance cardiography – method of rapid assessment and monitoring of hemodynamic state. Folia Cardiologica Excerpta 2, 6 (2007) (in Polish)
Szczeklik, A., Tendera, M.: Cardiology. The textbook based on EBM, Cracow, vol. I. Practical Medicine Publishing (2009)
Water, G.A., et al.: Bioelectric impedance. New developments and clinical application. Arch. Surg. 4, 355 (1971)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Przywara-Chowaniec, B., Poloński, L., Gawlikowski, M., Pustelny, T. (2012). Research into the Possibility to Use Impedance Rheocardiography in a Non-invasive Assessment of Haemodynamic Condition of Patients with Heart Diseases. In: Piętka, E., Kawa, J. (eds) Information Technologies in Biomedicine. Lecture Notes in Computer Science(), vol 7339. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31196-3_18
Download citation
DOI: https://doi.org/10.1007/978-3-642-31196-3_18
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-31195-6
Online ISBN: 978-3-642-31196-3
eBook Packages: Computer ScienceComputer Science (R0)