Abstract
We investigated the appropriateness of four different mammography phantoms for image quality evaluation in Digital Breast Tomosynthesis (DBT). We tested the CIRS BR3D phantom, the ACR Prototype FFDM Accreditation Phantom, the Penn anthropomorphic breast phantom and the Quart mam/digi EPQC phantom. This work discusses the advantages and shortcomings of each phantom and concludes that none of them, in their current form, can be considered to be adequate as an image quality evaluation phantom for DBT.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Li, B., Saunders, R., Uppaluri, R.: Measurement of slice thickness and in-plane resolution on radiographic tomosynthesis system using modulation transfer function (MTF). In: Proc. SPIE 6142, 61425D (2006)
Bouwman, R., Visser, R., Young, K., Dance, D., Lazzari, B., van der Burght, R., Heide, P., van Engen, R.: Daily quality control for breast tomosynthesis. In: Proc. SPIE 7622, 762241 (2010)
Vecchio, S., Albanese, A., Vignoli, P., Taibi, A.: A novel approach to digital breast tomosynthesis for simultaneous acquisition of 2D and 3D images. European Radiology 21, 1207–1213 (2011)
Feng, S.S.J., Sechopoulos, I.: A software-based x-ray scatter correction method for breast tomosynthesis. Medical Physics 38, 6643–6653 (2011)
Carton, A.K., Bakic, P., Ullberg, C., Derand, H., Maidment, A.D.A.: Development of a physical 3D anthropomorphic breast phantom. Medical Physics 38, 891–896 (2011)
Carton, A.K., Bakic, P., Ullberg, C., Maidment, A.D.A.: Development of a 3D high-resolution physical anthropomorphic breast phantom. In: Proc. SPIE 7622, 762206–1 (2010)
Bakic, P.R., Zhang, C., Maidment, A.D.A.: Development and characterization of an anthropomorphic breast software phantom based upon region-growing algorithm. Medical Physics 38, 3165–3176 (2011)
de las Heras, H., Peng, R., Zeng, R., Freed, M., O´Bryan, E., Jennings, R.J.: A versatile laboratory platform for studying x-ray 3D breast imaging. In: Proceedings of IEEE Medical Imaging Conference MIC12.M-17 (2011)
de las Heras, H., Schöfer, F., Tiller, B., del RÃo, M.C., Zwettler, G., Semturs, F.: A new method for dosimetry and image quality assurance in mammography and breast tomosynthesis. In: Proc. IRPA (2012)
Perry, N., Broeders, M., de Wolf, C., Törnberg, S., Holland, R., von Karsa, L.: European guidelines for quality assurance in breast cancer screening and diagnosis - 4th (edn.) Technical report, Office for Official Publications of the European Communities (2006)
Richard, S., Samei, E.: Quantitative breast tomosynthesis: From detectability to estimability. Medical Physics 37, 6157–6165 (2010)
Richard, S., Samei, E.: Quantitative imaging in breast tomosynthesis and CT: Comparison of detection and estimation task performance. Medical Physics 37, 2627–2637 (2010)
IEC: 62220-1-2:2007 Medical electrical equipment - Characteristics of digital X-ray imaging devices - Part 1-2: Determination of the detective quantum efficiency - Detectors used in mammography. Technical report, International Electrotechnical Commission (2007)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Brunner, C.C. et al. (2012). Evaluation of Various Mammography Phantoms for Image Quality Assessment in Digital Breast Tomosynthesis. In: Maidment, A.D.A., Bakic, P.R., Gavenonis, S. (eds) Breast Imaging. IWDM 2012. Lecture Notes in Computer Science, vol 7361. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31271-7_37
Download citation
DOI: https://doi.org/10.1007/978-3-642-31271-7_37
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-31270-0
Online ISBN: 978-3-642-31271-7
eBook Packages: Computer ScienceComputer Science (R0)