Abstract
Seven Hologic Dimensions digital breast tomosynthesis (DBT) systems have been installed for the TOMMY trial, a UK based multi-centre trial comparing conventional 2D digital mammography with DBT. In the absence of established guidelines for DBT quality control, a specific protocol was developed and applied. Physics tests of 2D and DBT performance were conducted at baseline and are repeated every 6 months, and include dose to the European standard breast model, tomosynthesis contrast to noise ratio, geometric distortion, z-resolution and threshold contrast detail detection. In addition routine performance checks (daily, weekly and monthly) are conducted on each system and reviewed centrally. Doses delivered under automatic exposure control by the systems were found to be well matched, with a mean glandular dose for the standard breast model (53mm equivalent breast thickness) of 1.89 mGy (range 1.79 to 2.00 mGy) for DBT and 1.41 mGy (range 1.36 to 1.48 mGy) for 2D imaging. Detector performance and image quality measurements were also well matched. All the systems exceeded the achievable image quality standard in the European guidelines for conventional digital mammography.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
van Engen, R.E., Bouwman, R., van der Burght, R., Lazzari, B., Dance, D.R., Heid, P., Aslund, M., Young, K.C.: Image Quality Measurements in Breast Tomosynthesis. In: Krupinski, E.A. (ed.) IWDM 2008. LNCS, vol. 5116, pp. 696–702. Springer, Heidelberg (2008)
Bouwman, R.W., Visser, R., Young, K.C., Dance, D.R., Lazzari, B., van der Burght, R., Heid, P., van Engen, R.E.: Daily quality control for breast tomosynthesis. In: Hsieh, J., Samei, E. (eds.) Medical Imaging 2010: The Physics of Medical Imaging (2010)
European Commission (EC): European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis, 4th edn. Office for Official Publications of the European Communities, Luxembourg (2006)
Dance, D.R., Young, K.C., van Engen, R.E.: Estimation of mean glandular dose for breast tomosynthesis: factors for use with the UK, European and IAEA breast dosimetry protocols. Phys. Med. Biol. 56, 453–471 (2011)
IEC 62220-1-2: Medical electrical equipment – Characteristics of digital X-ray imaging devices – Part 1.2: Determination of the detective quantum efficiency – Detectors used in mammography (2007)
CDCOM version 1.6 available from EUREF website, euref.org
CDMAM analysis UK v1.4, NCCPM, Guildford, UK
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Strudley, C.J., Young, K.C., Oduko, J.M., Looney, P., Barnard, A., Gilbert, F.J. (2012). Development of a Quality Control Protocol for Digital Breast Tomosynthesis Systems in the TOMMY Trial. In: Maidment, A.D.A., Bakic, P.R., Gavenonis, S. (eds) Breast Imaging. IWDM 2012. Lecture Notes in Computer Science, vol 7361. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-31271-7_43
Download citation
DOI: https://doi.org/10.1007/978-3-642-31271-7_43
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-31270-0
Online ISBN: 978-3-642-31271-7
eBook Packages: Computer ScienceComputer Science (R0)