Abstract
Iterative reconstruction (IRT) makes it possible to acquire computed tomographic colonography (CTC) images at <50% of the radiation dose of conventional standard-dose filtered back-projection (FBP) without impairing image quality. It has also other significant advantages over FBP, including better noise suppression, reduction of image artifacts, and flexible mathematical formulation. In this pilot study, we explored the potential application of IRT in the implementation of an ultra-low-dose (ULD) laxative-free CTC examination. First, CTC images are reconstructed approximately with FBP to detect regions of fecal tagging and other high-density objects that can generate image artifacts. Next, the detected regions are projected to sinogram domain to guide the IRT process for the minimization of image noise, correction of beam-hardening artifacts, and virtual cleansing of fecal-tagged regions. For pilot evaluation, five patients were prepared for an ULD dual-energy CTC examination by use of non-cathartic dietary fecal tagging with iodine. For one patient, the CTC images were reconstructed by use of both the FBP and IRT methods. Preliminary results showed that the IRT-reconstructed images demonstrated superior image quality over the FBP-reconstructed images.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Gluecker, T., Johnson, C., Harmsen, W., Offord, K., Harris, A., et al.: Colorectal cancer screening with CT colonography, colonoscopy, and double-contrast barium enema examination: prospective assessment of patient perceptions and preferences. Radiology 227, 378–384 (2003)
Zalis, M., Blake, M., Cai, W., Hahn, P., et al.: Diagnostic accuracy of laxative-free computed tomographic colonography for detection of adenomatous polyps in asymptomatic adults: a prospective evaluation. Ann. Intern. Med. 156, 692–702 (2012)
Chang, K., Yee, J.: Dose reduction methods for CT colonography. Abdom. Imaging 38, 224–232 (2013)
Xu, Y., He, W., Chen, H., Hu, Z., Li, J., Zhang, T.: Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CT. Clin. Radiol. (2013)
Boellaard, T., Venema, H., Streekstra, G., Stoker, J.: Effective radiation dose in CT colonography: is there a downward trend? Acad. Radiol. 19, 1127–1133 (2012)
Boas, F., Fleischmann, D.: CT artifacts: causes and reduction techniques. Imaging Med. 4, 229–240 (2012)
Do, S., Karl, W., Liang, Z., Kalra, M., Brady, T., Pien, H.: A decomposition-based CT reconstruction formulation for reducing blooming artifacts. Phys. Med. Biol. 56, 7109–7125 (2011)
Chan, T., Mulet, P.: On the convergence of the lagged diffusivity fixed point method in total variation image restoration. SIAM J. Numer. Anal. 36, 354–367 (1999)
Siddon, R.: Fast calculation of the extract radiological path for a three-dimensional CT array. Med. Phys. 12, 252 (1985)
Do, S., Cho, S., Karl, W., Kalra, M., Brady, T., Pien, H.: Accurate model-based high resolution cardiac image reconstruction in dual source CT. In: IEEE International Symposium on Biomedical Imaging: From Nano to Macro, pp. 330–333. IEEE Press, Boston (2009)
Hsieh, J., Molthen, R., Dawson, C., Johnson, R.: An iterative approach to the beam hardening correction in cone beam CT. Med. Phys. 27, 23–29 (2000)
Näppi, J., Yoshida, H.: Fully automated three-dimensional detection of polyps in fecal-tagging CT colonography. Acad. Radiol. 25, 287–300 (2007)
Do, S., Liang, Z., Karl, W., Brady, T., Pien, H.: A projection-driven pre-correction technique for iterative reconstruction of helical cone-beam cardiac CT images. In: Proc. SPIE Medical Imaging: Physics of Medical Imaging, vol. 6913. SPIE Press (2008)
Brooks, R.: A quantitative theory of the Hounsfield unit and its application to dual energy scanning. J. Comput. Assist. Tomogr. 1, 487–493 (1977)
Jacobs, F., Sundermann, E., De Sutter, B., Christiaens, M., Lemahieu, I.: A fast algorithm to calculate the extract radiological path through a pixel or voxel space. J. Comput. Inf. T. 6, 89–94 (1998)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Do, S., Näppi, J.J., Yoshida, H. (2013). Iterative Reconstruction for Ultra-Low-Dose Laxative-Free CT Colonography. In: Yoshida, H., Warfield, S., Vannier, M.W. (eds) Abdominal Imaging. Computation and Clinical Applications. ABD-MICCAI 2013. Lecture Notes in Computer Science, vol 8198. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-41083-3_12
Download citation
DOI: https://doi.org/10.1007/978-3-642-41083-3_12
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-41082-6
Online ISBN: 978-3-642-41083-3
eBook Packages: Computer ScienceComputer Science (R0)