Abstract
Registration of two images is difficult if large deformations are induced due to the absence of a structure in one image. We propose a penalty term that minimizes the volume of the missing structure in one image during free-form registration. The registration optimum found is based on image similarity, provided that the missing volume is minimal. We demonstrate our method on cervical MR images for brachytherapy. The intrapatient registration problem involves one image in which a therapy applicator is present and one in which it is not. Experiments show improvement of registration when including the penalty term. The improvements of surface distance and overlap of the bladder and rectum (which are close to the applicator volume) provide proof of principle of our method.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Nithiananthan, S., Schafer, S., Mirota, D.J., Stayman, J.W., Zbijewski, W., Reh, D.D., Gallia, G.L., Siewerdsen, J.H.: Extra-dimensional Demons: a method for incorporating missing tissue in deformable image registration. Med. Phys. 39(9), 5718–5731 (2012)
Periaswamy, S., Farid, H.: Medical image registration with partial data. Med. Image Anal. 10(3), 452–464 (2006)
Gu, Z., Qin, B.: Nonrigid Registration of Brain Tumor Resection MR Images Based on Joint Saliency Map and Keypoint Clustering. Sensors 9(12), 10270–10290 (2009)
Risholm, P., Samset, E., Talos, I.-F., Wells, W.: A non-rigid registration framework that accommodates resection and retraction. In: Prince, J.L., Pham, D.L., Myers, K.J. (eds.) IPMI 2009. LNCS, vol. 5636, pp. 447–458. Springer, Heidelberg (2009)
Chitphakdithai, N., Duncan, J.S.: Non-rigid registration with missing correspondences in preoperative and postresection brain images. In: Jiang, T., Navab, N., Pluim, J.P.W., Viergever, M.A. (eds.) MICCAI 2010, Part I. LNCS, vol. 6361, pp. 367–374. Springer, Heidelberg (2010)
Zacharaki, E.I., Hogea, C.S., Shen, D., Biros, G., Davatzikos, C.: Non-diffeomorphic registration of brain tumor images by simulating tissue loss and tumor growth. Neuroimage 46(3), 762–774 (2009)
Miga, M.I., Roberts, D.W., Kennedy, F.E., Platenik, L.A., Hartov, A., Lunn, K.E., Paulsen, K.D.: Modeling of retraction and resection for intraoperative updating of images. Neurosurgery 49(1), 75–84 (2001)
Vigneron, L.M., Noels, L., Warfield, S.K., Verly, J.G., Robe, P.A.: Serial FEM/XFEM-Based Update of Preoperative Brain Images Using Intraoperative MRI. Int. J. Biomed. Imaging 2012, 872783 (2012)
Klein, S., Staring, M., Murphy, K., Viergever, M.A., Pluim, J.P.: elastix: a toolbox for intensity-based medical image registration. IEEE Trans. Med. Imaging 29(1), 196–205 (2010)
Commandeur, F., Velut, J., Acosta, O.: A VTK algorithm for the computation of the Hausdorff distance. Midas Journal (September 2011)
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer-Verlag Berlin Heidelberg
About this paper
Cite this paper
Berendsen, F.F., Kotte, A.N.T.J., de Leeuw, A.A.C., Viergever, M.A., Pluim, J.P.W. (2013). Free-Form Registration Involving Disappearing Structures: Application to Brachytherapy MRI. In: Yoshida, H., Warfield, S., Vannier, M.W. (eds) Abdominal Imaging. Computation and Clinical Applications. ABD-MICCAI 2013. Lecture Notes in Computer Science, vol 8198. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-41083-3_16
Download citation
DOI: https://doi.org/10.1007/978-3-642-41083-3_16
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-41082-6
Online ISBN: 978-3-642-41083-3
eBook Packages: Computer ScienceComputer Science (R0)