Automatic Removal of Externally Attached Fiducial Markers in Cone Beam C-Arm CT

  • Chapter
  • First Online:

Part of the book series: Informatik aktuell ((INFORMAT))

Abstract

In computed tomography fiducial markers are frequently used to obtain accurate point correspondences for further processing. These markers typically cause metal artefacts, decreasing image quality of the subsequent reconstruction and are therefore often removed from the projection data. The placement of such markers is usually done on a surface, separating two materials, e.g. skin and air. Hence, a correct restoration of the occluded area is difficult. In this work six state-of-the-art interpolation techniques for the removal of high-density fiducial markers from cone-beam CT projection data are compared. We conducted a qualitative and quantitative evaluation for the removal of such markers and the ability to reconstruct the adjoining edge. Results indicate that an iterative spectral deconvolution is best suited for this application, showing promising results in terms of edge, as well as noise restoration.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   79.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   84.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Mitrovic U, Spiclin Z, Likar B, et al. 3D –2D registration of cerebral angiograms: a method and evaluation on clinical images. IEEE Trans Med Imaging. 2013;32(8):1550–63.

    Article  Google Scholar 

  2. Aach T, Metzler VH. Defect interpolation in digital radiography: how objectoriented transform coding helps. Proc SPIE. 2001;4322:824–35.

    Google Scholar 

  3. Schwemmer C, Pr¨ummer M, Daum V, et al. High-density object removal from projection images using low-frequency-based object masking. Proc BVM. 2010; p. 365–9.

    Google Scholar 

  4. Loy G, Zelinsky A. Fast radial symmetry for detecting points of interest. IEEE Trans Pattern Anal Mach Intell. 2003;25(8):959–73.

    Article  Google Scholar 

  5. Kapur J, Sahoo PK, Wong A. A new method for gray-level picture thresholding using the entropy of the histogram. Computer Vis Graph Image Process. 1985;29(3):273–85.

    Article  Google Scholar 

  6. Marchant TE, Amer AM, Moore CJ. Measurement of inter and intra fraction organ motion in radiotherapy using cone beam CT projection images. Phys Med Biol. 2008;53(4):1087.

    Article  Google Scholar 

  7. Knutsson H, Westin CF. Normalized and differential convolution: methods for interpolation and filtering of incomplete and uncertain data. Proc Computer Vis Pattern Recognit. 1993; p. 515–23.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Martin Berger .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Berger, M. et al. (2014). Automatic Removal of Externally Attached Fiducial Markers in Cone Beam C-Arm CT. In: Deserno, T., Handels, H., Meinzer, HP., Tolxdorff, T. (eds) Bildverarbeitung für die Medizin 2014. Informatik aktuell. Springer, Berlin, Heidelberg. https://doi.org/10.1007/978-3-642-54111-7_59

Download citation

Publish with us

Policies and ethics