Abstract
this paper shows the values of Flow ratio (FR) for control of an absorption double stage heat transformer. The main parameters for the heat pump system are defined as COP, FR and GTL. The control of the entire system is based in a new definition of FR. The heat balance of the Double Stage Heat Transformer (DSHT) is used for the control. The mass flow is calculated for a HPVEE program and a second program control the mass flow. The mass flow is controlled by gear pumps connected to LabView program. The results show an increment in the fraction of the recovery energy. An example of oil distillation is used for the calculation. The waste heat energy is added at the system at 70 °C. Water ™ - Carrol mixture is used in the DSHT. The recover energy is obtained in a second absorber at 128 °C with two scenarios.
Keywords
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
R. J. Romero, Sotsil Silva – Sotelo, Comparison of instrumental methods for in-line determination of LiBr concentration in solar absorption thermal systems, Solar Energy Materials And Solar Cells, Vol. 90 ,Issue 15, 2006, pp. 2549 – 2555.
Romero R. J.; Rivera W; Best R. Comparison of the theoretical performance of a solar air conditioning system operating with water / lithium bromide and an aqueous ternary hydroxide; Solar Energy Materials & solar Cells, Vol. 63, pp 387 – 399, 2000
Romero R. J.; Rivera W.; Pilatowsky I.; Best R.; Comparison of the modeling of a solar absorption system for simultaneous cooling and heating operating with an aqueous ternary hydroxide and with water / lithium bromide; Solar Energy Materials & solar Cells, Vol. 70, pp 301 – 308, 2001
Acknowledgements
The authors thank to the project: “Desarrollo y aplicación de un sistema de refrigeración termo solar autosuficiente y sustentable para conservación de productos perecederos en comunidades costeras alejas de la red” for partial support.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2010 Springer Science+Business Media B.V.
About this paper
Cite this paper
Silva-Sotelo, S., Romero, R.J., Rodríguez – Martínez, A. (2010). Double Stage Heat Transformer Controlled by Flow Ratio. In: Sobh, T., Elleithy, K. (eds) Innovations in Computing Sciences and Software Engineering. Springer, Dordrecht. https://doi.org/10.1007/978-90-481-9112-3_100
Download citation
DOI: https://doi.org/10.1007/978-90-481-9112-3_100
Published:
Publisher Name: Springer, Dordrecht
Print ISBN: 978-90-481-9111-6
Online ISBN: 978-90-481-9112-3
eBook Packages: Computer ScienceComputer Science (R0)