Abstract
Mosaic architecture based digital mammography is attractive since it offers an affordable and scaleable solution towards obtaining high resolution digital mammograms. Limitations on the clinical usability of the architecture are associated with the x-ray conversion screen utilized and to the methods employed to reconstruct the final digital mammogram. The x-ray conversion screen imposes limits on the efficiency of the optical conversion and the resolution of the finest resolvable detail. This can be addressed to an extent via use of specialized materials [1]. Reconstruction techniques, on the other hand, are likely to introduce artifacts in the final image. This can be addressed by employing complex reconstruction algorithms, which consequently may increase the time required to generate the final image.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
J. A. Rowlands, D. M. Hunter and N. Araj, “X-Ray Imaging Using Amorphous Selenium: A photoinduced discharge readout method for digital mammography”, Med. Phys., Vol. 18, pp. 421–431, 1991.
Scott T. Smith, Hyunkeun Kim, Vivek Swarnakar, Myoungki Jeong and Darold C. Wobschall, “Parallel hardware architecture for CCD-mosaic digital mammography”, SPIE Medical Imaging — 98.
V. Swarnakar, M. Jeong, R. Wasserman, E. Andres and D. Wobschall, “An Integrated Distortion Correction and Reconstruction Technique For Digital Mosaic Mammography”, SPIE Medical Imaging, vol. 3031, pp. 673, 1997.
MIAS Database: http://skye.icr.ac.uk/miasdb/miasdb.html
R. Salvi, “Introduction to Applied Statistical Signal Analysis”, IRWIN 1991.
A. K. Jain, “Fundamentals of Digital Image Processing”, Prentice Hall 1989.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1998 Springer Science+Business Media Dordrecht
About this chapter
Cite this chapter
Swarnakar, V., Smith, S.T., Jeong, M., Kim, H., Wobschall, D. (1998). Evaluation of a Digital Mosaic Mammography Imager. In: Karssemeijer, N., Thijssen, M., Hendriks, J., van Erning, L. (eds) Digital Mammography. Computational Imaging and Vision, vol 13. Springer, Dordrecht. https://doi.org/10.1007/978-94-011-5318-8_6
Download citation
DOI: https://doi.org/10.1007/978-94-011-5318-8_6
Publisher Name: Springer, Dordrecht
Print ISBN: 978-94-010-6234-3
Online ISBN: 978-94-011-5318-8
eBook Packages: Springer Book Archive