Abstract
The Anterior Cruciate Ligament (ACL) is one of the four main ligaments of the knee and crucial to stabilizing the knee. In the surgery of arthroscopic ACL reconstruction after ruptures, the precise intraoperative localization of the entry point of the femoral tunnel is one of the key factors affecting the function of knee. In this paper, a new method is proposed to rapidly achieve the localization of the entry point. A special probe should be registered firstly so that its tip position is measured in real time. Then the point cloud of probe tip’s trajectories is obtained when outlining the cartilage posterior edge of lateral condyle. In order to simplify the way to confirm if the entry point of the femoral tunnel is in the preoperative planning position, a projection transformation is applied finally to reduce the dimensions. Besides, the experimental results show that the method can meet the demands of the surgery for ACL reconstruction.
Keywords
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Swischuk, L.E., Jadhav, S.P.: Knee and Leg. Springer, New York (2014)
Maffulli, N., Osti, L.: ACL stability, function, and arthritis: what have we been missing. Orthopedics 36(36), 90–92 (2013)
Stergiou, N., Ristanis, S., Moraiti, C.: Tibial rotation in anterior cruciate ligament (ACL)-deficient and ACL-reconstructed knees. Dept. Comput. Sci. 38(8), 2638–2641 (1998)
Zabala, M.E., Favre, J., Andriacchi, T.P.: Relationship between knee mechanics and time since injury in ACL-deficient knees without signs of osteoarthritis. Am. J. Sports Med. 5, 1189–1196 (2015)
Lubowitz, J.H.: Editorial commentary: ACL reconstruction: single-bundle versus double-bundle. Arthrosc. J. Arthrosc. Relat. Surg. 6, 1197–1198 (2015)
Kostov, H., Stojmenski, S., Kostova, E.: Reliability assessment of arthroscopic findings versus MRI in ACL injuries of the knee. Acta Inform. Med. 2, 111–114 (2014)
Kawakami, Y., Hiranaka, T., Matsumoto, T., et al.: The accuracy of bone tunnel position using fluoroscopic-based navigation system in anterior cruciate ligament reconstruction. Knee Surg. Sports Traumatol. Arthrosc. 20(20), 1503–1510 (2012)
Fernandes, T.L., Fregni, F., Weaver, K., et al.: The influence of femoral tunnel position in single-bundle ACL reconstruction on functional outcomes and return to sports. Knee Surg. Sports Traumatol. Arthrosc. 1, 97–103 (2014)
Domnick, C., Herbort, M., Raschke, M.J., et al.: Conventional over-the-top-aiming devices with short offset fail to hit the center of the human femoral ACL footprint in medial portal technique, whereas medial-portal-aiming devices with larger offset hit the center reliably. Arch. Orthop. Traumatol. Surg. 136, 499–504 (2015). Fischer, H., Vogel, B., Pfleging, W., Besser, H.: Flexible distal tip made of nitinol (NiTi) for a steerable endoscopic camera system, Materials Science and Engineering, P273–275, 780–783 (1999)
Plaweski, S., Rossi, J., Merloz, P., et al.: Analysis of anatomic positioning in computer-assisted and conventional anterior cruciate ligament reconstruction. Orthop. Traumatol. Surg. Res. 97(6), S80–S85 (2011)
Luites, J.W.H., Wymenga, A.B., Blankevoort, L., et al.: Accuracy of a computer-assisted planning and placement system for anatomical femoral tunnel positioning in anterior cruciate ligament reconstruction. Int. J. Med. Rob. Comput. Assist. Surg. 10(4), 438–446 (2014)
Ortmaier, T., Weiss, H., Döbele, S., et al.: Experiments on robot-assisted navigated drilling and milling of bones for pedicle screw placement. Int. J. Med. Rob. 2, 350–363 (2006)
Axelsson, O., Neytcheva, M.: The algebraic multilevel iteration methods – theory and applications (1994)
Blanchet, G., Charbit, M., Blanchet, G., et al.: The Least Squares Method. Digital Signal and Image Processing Using Matlab®, 2nd edn., pp. 349–395. Wiley, Hoboken (2014)
Hu, R., Yue, C., Xie, J.: Joint optimization of age replacement and spare ordering policy based on genetic algorithm. In: International Conference on Computational Intelligence & Security, pp. 156–161 (2008)
Dastani, M., Ardebili, M.: Optimal design and analysis simulation of an outer rotor hybrid excited generator for wind energy conversion systems. In: Proceedings of Electrical Engineering. IEEE (2015)
Su, C.H., Hou, T.H.: Using multi-population intelligent genetic algorithm to find the pareto-optimal parameters for a nano-particle milling process. Expert Syst. Appl. 34(4), 2502–2510 (2008)
Ling, S.H., Lam, H.K., Leung, F.H.F., et al:. A novel GA-based neural network for short-term load forecasting. In: Proceedings of the 2002 International Joint Conference on Neural Networks, IJCNN 2002, pp. 2761–2766. IEEE (2002)
Acknowledgments
This research is supported by the National High-tech R&D Program of China (No. 2015AA043201), Key Fundamental Research Program of Shenzhen (No. JCYJ20140417113430650), Guangdong Science and Technology Scheme (No. 2014A020215027 and 2014A020215030) and Research and Development Project of Guangdong Key Laboratory of Robotics and Intelligent Systems (No. ZDSYS20140509174140672).
Author information
Authors and Affiliations
Corresponding authors
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Lei, L. et al. (2017). An Intraoperative Localization Method of Femoral Tunnel Entry Point for ACL Reconstruction. In: Sun, F., Liu, H., Hu, D. (eds) Cognitive Systems and Signal Processing. ICCSIP 2016. Communications in Computer and Information Science, vol 710. Springer, Singapore. https://doi.org/10.1007/978-981-10-5230-9_30
Download citation
DOI: https://doi.org/10.1007/978-981-10-5230-9_30
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-5229-3
Online ISBN: 978-981-10-5230-9
eBook Packages: Computer ScienceComputer Science (R0)