Abstract
This paper focuses on the impact of low temperature environment on the measurement performance of smart meter. Based on the actual test data of the smart meter in the low temperature environment and processing software such as Matlab and Origin, we can investigate the relationship and influence level among the low temperature environment, operating load and metering performance of the smart meter. The data from the test field of smart meter in the actual operating condition of low temperature is set up in Mohe county of Heilongjiang province. The test functions of the meter include short and long-distance detection system, load control system, protection system and environmental monitoring system. And the research results show that the low temperature environment induces a shift to negative direction of the smart meter error, so that we can obtain the mathematical model of the smart meter with the change of temperature at different loads.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Jia, M., Gu, X., Guo, Q., et al.: Broadband hybrid satellite-terrestrial communication systems based on cognitive radio toward 5G. IEEE Wirel. Commun. 23(6), 96–106 (2017)
Yu, Y., Luan, W.: Smart grid and its implementations. Proc. CSEE 29(34), 1–8 (2009)
Jia, M., Wang, L., Yin, Z., et al.: A novel spread slotted ALOHA based on cognitive radio for satellite communications system. EURASIP J. Wireless Commun. Netw. 2016(1), 232 (2016)
Li, H., Xia, J.: Influence of environment temperature variation on verification result of the electricity meter and its compensation. Meas. Tech. 7, 38–39 (2001)
Wang, S.T., Hui, Z., Yuan, R.M., et al.: Concept and application of smart meter. Power Syst. Technol. 34(4), 17–23 (2010)
Cui, T., Gao, F., Ho, T., et al.: Distributed space-time coding for two-way wireless relay networks. In: IEEE International Conference on Communications, pp. 3888–3892. IEEE (2008)
Jing, E.B.: Smart meter system design in smart grid advanced metering infrastructure AMI. Electric. Meas. Instrum. (2010)
Jia, M., Xue, W., Gu, X., Guo, Q.: A simplified multiband sampling and detection method based on MWC structure for mm wave communications in 5G wireless networks. Int. J. Antennas Propag. 2015, 1–10 (2015)
Wang, Z., Chen, L.: Application of multivariate linear regression statistical forecast model. Stat. Decis. 5, 46–47 (2008)
Acknowledgement
This paper is supported by Research on Performance Verification Platform Technology of Electric Energy Metering Equipment Based on Typical Environmental Conditions(Grant No. 5442JL160013).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Yin, X., Liu, H., Yin, C., Man, J. (2019). The Error Model of the Smart Meter Under the Influence of Low Temperature. In: Liang, Q., Mu, J., Jia, M., Wang, W., Feng, X., Zhang, B. (eds) Communications, Signal Processing, and Systems. CSPS 2017. Lecture Notes in Electrical Engineering, vol 463. Springer, Singapore. https://doi.org/10.1007/978-981-10-6571-2_232
Download citation
DOI: https://doi.org/10.1007/978-981-10-6571-2_232
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-10-6570-5
Online ISBN: 978-981-10-6571-2
eBook Packages: EngineeringEngineering (R0)