Skip to main content

Analysis on Network Transmission Delay of Intelligent Substation

  • Conference paper
  • First Online:
  • 48 Accesses

Part of the book series: Lecture Notes in Electrical Engineering ((LNEE,volume 463))

Abstract

The various factors are resumed which affect the network transmission delay in intelligent substation. The accumulate calculation method of network transmission delay in intelligent substation is introduced particularly. The method is applied to calculate the network transmission delay of simple Ethernet, IEC61850-9-2 communication network, complex Ethernet, mixed network communication theoretically. At last, the impact of the indexes on the network transmission delay is analyzed.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Qi, X.-Y., Dou, Q.: Analysis and optimization of delay performance of bufferless optical interconnection network. Comput. Eng. 36(5), 12–14 (2010)

    Google Scholar 

  2. Li-Zi, X.: Requirement of IEC 61850 to performance of messages for substation automation system. Power Syst. Technol. 11(1), 1–3 (2002)

    Google Scholar 

  3. 57/526/VDV. IEC 61850-5 Communication network and systems in substations, Part 5–12: Message performance requirements (2001)

    Google Scholar 

  4. He, L., Hao, X.-G.: Acceptance test technology of communication network in digitalized substation. Relay. 10(1), 75–78 (2010)

    Google Scholar 

  5. Xu, W.-J., Xiao, X.-A.: Investigation and application of integrated state monitoring system for intelligent substation. Shanxi Electric Power. 38(10), 33–36 (2010)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tiecheng Li .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2019 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Li, T., Sun, L., Guo, S., Zhang, L. (2019). Analysis on Network Transmission Delay of Intelligent Substation. In: Liang, Q., Mu, J., Jia, M., Wang, W., Feng, X., Zhang, B. (eds) Communications, Signal Processing, and Systems. CSPS 2017. Lecture Notes in Electrical Engineering, vol 463. Springer, Singapore. https://doi.org/10.1007/978-981-10-6571-2_42

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-6571-2_42

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-6570-5

  • Online ISBN: 978-981-10-6571-2

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics