Skip to main content
Log in

Design of ICs applying built-in current testing

  • Published:
Journal of Electronic Testing Aims and scope Submit manuscript

Abstract

Built-in Current (BIC) sensors have proven to be very useful in testing static CMOS ICs. In a number of experimental ICs BIC sensors were able to detect small abnormal I DDQ currents. This paper discusses the design of the circuit under test and Built-in Current (BIC) sensors, which provide: maximum level of defect detectability, minimum impact of BIC sensor on the performance of the circuit under test and minimum area overhead needed for BIC sensors implementation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. J.M. Acken, “Testing for bridging faults (shorts) in CMOS circuits,” Proc. Dig. Autom. Conf., San Francisco, CA, pp. 717–718, July 1983.

  2. M. Levi, “CMOS is most testable,” Int. Test Conf., Washington, DC, pp. 217–221, September 1987.

  3. Y.K. Malaiya and S.Y.H. Su, “A new fault modeling and testing technique for CMOS devices,” Int. Test Conf., Philadelphia, PA, pp. 25–34, September 1982.

  4. T.M. Storey and W. Maly, “CMOS bridging fault detection,” Proc. of the Int. Test Conf., Washington, DC, pp. 842–851, September 1990.

  5. W. Maly and M. Patyra, “Built-in current testing,” IEEE Trans. on Solid State Circuits, vol. 27, pp. 425–428, March 1992.

    Google Scholar 

  6. J.M. Soden and C.F. Hawkins, “Test considerations for gate oxide shorts in CMOS ICs,” IEEE Design and Test, pp. 56–64, August 1986.

  7. W. Maly and P. Nigh, “Built-in current testing—feasibility study,” Proc. Int. Conf. on Computer-Aided Design, Santa Clara, CA, pp. 340–343, November 1988.

  8. W. Maly and P. Nigh, “Built-in current testing of integrated circuits,” US Pat. No. 5,025,344, June 1991.

  9. D. Feltham, P. Nigh, L.R. Carley, and W. Maly, “Current sensing for built-in testing of CMOS circuits,” Proc. Intern. Conf. on Computer Design, Rye Brook, NY, pp. 454–457, October 1988.

  10. K. Kettler, “Current monitoring circuits for fault detection in CMOS systems,” M.S. dissertation, Carnegie Mellon University, Pittsburgh, PA, 1989.

    Google Scholar 

  11. P. Nigh, “Built-in current testing,” Ph.D. dissertation, Carnegie Mellon University, Pittsburgh, PA, 1990.

    Google Scholar 

  12. W. Maly and P. Nigh, “Built-in current testing for VLSI circuits” Proc. of SRC TECHCON'88 Conf., Dallas, pp. 149–152, October 1988.

  13. W. Maly, “Design methodology for defect tolerant integrated circuits,” Proc. of CICC'88, Rochester, NY, pp. 27.5.1–27.5.4, May 1988.

  14. P. Nigh and W. Maly, “A self-testing ALU using built-in current sensing,” Proc. Custom Integrated Circuits Conf., Rochester, NY, pp. 22.1.1–22.1.4, May 1989.

  15. D.A. Hodges and H.G. Jackson, “Analysis and design of digital integrated circuits,” New York: McGraw-Hill, 1983.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

This research was supported by NSF Grant MIP8822805.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Maly, W., Patyra, M. Design of ICs applying built-in current testing. J Electron Test 3, 397–406 (1992). https://doi.org/10.1007/BF00135343

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00135343

Keywords