Skip to main content
Log in

Nullification of Electromagnetic Radiation: 50 Hz Artifact During Electroencephalogram Recording

  • Original Paper
  • Published:
Journal of Medical Systems Aims and scope Submit manuscript

Abstract

This paper discusses the 50-Hz artifact observed during EEG recording of three patients, using Mindset24 equipment in a biomedical laboratory along with other instruments. The artifact at 50 Hz is created due to electromagnetic (EM) radiation from the environment. Perhaps, the nullification of 50 Hz artifact occurs by the three important means such as (a) grounding of far-field EM current when the patient touches the equipment metal casing, (b) connecting the electrodes in a sequence to obtain differential potentials with suppressed near-field EM radiation potentials of the scalp, and (c) destructive interferences of the EM waves.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. John, S. B., and Bradford, A., The Electroencephalogram: Its Pattern and Origins. MIT Press, London, 1993.

    Google Scholar 

  2. Thomas, F. C., Phan, L., Gerald, R. S., and Don, T. M., Scalp electrode impedance, infection risk and EEG data quality. Clin. Neurophysiol. 112:536–544, 2001.

    Article  Google Scholar 

  3. Geddes, L. A., and Baker, L. E., Principles of Applied Biomedical Instrumentation. Wiley, New York, p. 745, 1989.

    Google Scholar 

  4. John, G., Medical Instrumentation Application and Design, 3rd ed. Wiley, New York, 1998.

    Google Scholar 

  5. Accardo, A., Affinito, M., Carrozzi, M., and Bouquet, F., Use of the fractal dimension for the analysis of electroencephalographic time series. Biol. Cybern. 77:339–350, 1997.

    Article  MATH  Google Scholar 

  6. Murali, S., Fractal and FFT power spectra analysis of human electro-encephalograms (brain waves) for six different odors. MSc dissertation, Nanyang Technological University, Singapore, 2005.

  7. Sihvola, A., Electromagnetic Mixing Formulas and Applications. The Institution of Electrical Engineers, London, 1999.

    Google Scholar 

  8. Keiser, B., Principles of Electromagnetic Compatibility, 3rd ed. ARTECH House, MA 1987.

    Google Scholar 

  9. Chatterton, P. A., and Houlden, M. A., EMC Electromagnetic Theory to Practical Design. Wiley, England, 1992.

    Google Scholar 

  10. Smith, G. S., An Introduction to Classical Electromagnetic Radiation. Cambridge University Press, Cambridge, England, 1997.

    Google Scholar 

  11. Smith, A. A., Radio Frequency Principles and Applications. The Institute of Electrical and Electronics Engineers, New York, pp. 10017–2394, 1998.

    Google Scholar 

  12. Dietrich, M. J., and Rafferty, C. F., The genotoxic potential of electric and magnetic field: An update. Mutat. Res. 411(1):45–86, 1998.

    Article  Google Scholar 

  13. Stronati, L., Testa, A., Villani, P., Marino, C., Lovisolo, G. A., Conti, D., Russo, F., Fresegna, A. M., and Cordelli, E., Absence of genotoxicity in human blood cells expose to 50 kHz magnetic fields as assessed by comet assay, chromosome aberration, micro nucleus, and sister chromatid exchange analysis. Bioelectromagnet 25:41–48, 2004.

    Article  Google Scholar 

  14. Testa, A., Cordelli, E., Stronati, L., Marino, C., Lovisolo, G. A., Fesegna, A. M., Conti, D., and Villani, P., Evaluation of genotoxic effect of low level 50 kHz magnetic fields on human blood cells using different cytogenetic assay. Bioelectromagnet 25:613–619, 2004.

    Article  Google Scholar 

Download references

Acknowledgments

The authors acknowledge grants provided by Nanyang Technological University Research Council (RG18/01) and Biomedical Engineering Research Center at in support of the project. Gratitude is submitted to Mrs Ma Tin Swe Hlaing, Mrs Anna Kulish and Mrs Bharathy Murali for the assistance provided during the experimentation.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. Murali.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Murali, S., Kulish, V.V. Nullification of Electromagnetic Radiation: 50 Hz Artifact During Electroencephalogram Recording. J Med Syst 30, 303–307 (2006). https://doi.org/10.1007/s10916-006-9017-0

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10916-006-9017-0

Keywords

Navigation