3D Surface Measurement for Medical Application—Technical Comparison of Two Established Industrial Surface Scanning Systems

  • Original Paper
  • Published:
Journal of Medical Systems Aims and scope Submit manuscript

Abstract

In 3D mapping of flexible surfaces (e.g. human faces) measurement errors due to movement or positioning occur. Aggravated by equipment- or researcher-caused mistakes considerable deviations can result. Therefore first the appliances’ precision handling and reliability in clinical environment must be established. Aim of this study was to investigate accuracy and precision of two contact-free 3D measurement systems (white light vs. laser). Standard specimens of known diameter for sphere deviation, touch deviation and plane deviation were tested. Both systems are appropriate for medical application acquiring solid data (<mm). The more complex white-light system shows better accuracy at 0.2 s measuring time. The laser system is superior concerning robustness, while accuracy is poorer and input time (1.5–2.5 s) longer. Due to the clinical demand the white-light system is superior in a laboratory environment, while the laser system is easier to handle under non-laboratory conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Farkas, L. G., Hajnis, K., and Posnick, J. C., Anthropometric and anthroposcopic findings of the nasal and facial region in cleft patients before and after primary lip and palate repair. Cleft Palate-Craniofac. J. 30:1–12, 1993.

    Article  Google Scholar 

  2. Ghoddousi, H., Edler, R., Haers, P., Wertheim, D., and Greenhill, D., Comparison of three methods of facial measurement. Int. J. Oral Maxillofac. Surg. 36:250–258, 2007.

    Article  Google Scholar 

  3. Kimoto, K., and Garrett, N. R., Evaluation of a 3D digital photographic imaging system of the human face. J. Oral Rehabil. 34:201–205, 2007.

    Article  Google Scholar 

  4. Gorniak, R. J. T., Kramer, E. L., Maguire Jr., G. Q., Noz, M. E., Schettino, C. J., and Zeleznik, M. P., Evaluation of a semiautomatic 3D fusion technique applied to molecular imaging and MRI brain/frame volume data sets. J. Med. Syst. 27:141–156, 2003.

    Article  Google Scholar 

  5. Bommanna Raja, K., Madheswaran, M., and Thyagarajah, K., Ultrasound kidney image analysis for computerized disorder identification and classification using content descriptive power spectral features. J. Med. Syst. 31:307–317, 2007.

    Article  Google Scholar 

  6. Ayoub, A., Garrahy, A., Hood, C., White, J., Bock, M., Siebert, J. P., et al., Validation of a vision-based, three-dimensional facial imaging system. Cleft Palate-Craniofac. J. 40:523–529, 2003.

    Article  Google Scholar 

  7. Schwenzer, K., Holberg, C., Willer, J., Mast, G., Ehrenfeld, M., 3-D imaging of the facial surface by topometry using projected white light strips. Mund Kiefer Gesichtschir. 2(Suppl 1):130–134, 1998.

    Article  Google Scholar 

  8. Kovacs, L., Zimmermann, A., Brockmann, G., Guhring, M, Baurecht, H., Papadopulos, N. A., et al., Three-dimensional recording of the human face with a 3D laser scanner. J. Plast. Reconstr. Aesthet. Surg. 59:1193–1202, 2006.

    Article  Google Scholar 

  9. Weinberg, S.M., Kolar, J.C. Three-dimensional surface imaging: limitations and considerations from the anthropometric perspective. J. Craniofac. Surg. 16:847–851, 2005.

    Article  Google Scholar 

  10. Amann, M. C., Bosch, T., Lescure, M., Myllyla, R., Rioux, M., Laser ranging: a critical review of usual techniques for distance measurement. Opt. Eng. 40:10–19, 2001.

    Article  Google Scholar 

  11. VIVID 900/VI-900 ® Konica Minolta Holdings Inc., Tokyo, Japan. Available from: http://www.minolta3d.com.

  12. Tricolite® Steinbichler Optotechnik GmbH, Neubeuern, Germany. Available from: http://www.steinbichler.com.

  13. Haberstok, C., Die Holographische Modalanalyse. Thesis in Applied Mechanics, Technical University, Munich, 2005.

  14. VDI/VDE-Norm. 2002 August.

Download references

Acknowledgement

These investigations were funded by the Suisse National Center of Competence in Research (SNF), “Computer aided and Image Guided Medical Interventions (Co-Me).”

The authors would like to thank the Steinbichler Company (Neubeuern, Germany) and the Minolta Company (Langenhagen, Germany) for technical support. The authors would further like to thank Petra Schwenzer and Virginia Dittrich for their editorial support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to K. Schwenzer-Zimmerer.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schwenzer-Zimmerer, K., Haberstok, J., Kovacs, L. et al. 3D Surface Measurement for Medical Application—Technical Comparison of Two Established Industrial Surface Scanning Systems. J Med Syst 32, 59–64 (2008). https://doi.org/10.1007/s10916-007-9108-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10916-007-9108-6

Keywords

Navigation