Skip to main content

Advertisement

Log in

Low-Cost and Active Control of Radiation of Wearable Medical Health Device for Wireless Body Area Network

  • Mobile & Wireless Health
  • Published:
Journal of Medical Systems Aims and scope Submit manuscript

Abstract

Wearable devices, wireless networks and body area networks have become an effective way to solve the problem of human health monitoring and care. However, the radiation problems of wireless devices, the power supply problems of wearable devices and the deployment of body area networks have become obstacles to their wide application in the field of health care. In order to solve the above problems, this paper studies and designs a wearable health medical body area network which is convenient for human health monitoring and medical care, starting from low-cost deployment of wireless wearable devices and active control of wireless radiation. Firstly, in order to avoid replacing equipment batteries, improve the relay and data aggregation capabilities of wireless body area network, and reduce the communication and computing load of edge devices, a deployment scheme of wireless medical health wearable devices is designed based on the optimal segmentation algorithm of Steiner spanning tree. Then, in order to minimize the charging cost and maximize the global charging utility of single source and multiple points in a finite time slot, an approximate algorithm for the optimal charging sequence based on 01 knapsack problem, i.e., the access path of wireless wearable devices, is designed. Then, an active radiation control algorithm for wearable medical health body area network is proposed, which can actively control the transmission power and radiation status of these wireless devices. Finally, simulation results show that the proposed algorithm is better than battery-powered wireless body area network and wireless rechargeable body area network, 16% and 44% reduction of devices, 25%和13% reduction of energy consumption, 26% reduction of radiation, and 5.18 and 1.13 times improvement of signal quality.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Latré, B., Braem, B., Moerman, I. et al., A survey on wireless body area networks. Wirel. Netw 17(1):1–18, 2011.

    Article  Google Scholar 

  2. Jain, P. C., Wireless Body Area Network for Medical Healthcare. IETE Tech. Rev. 28(4):362–371, 2011.

    Article  Google Scholar 

  3. Ben Elhadj, H., Chaari, L., and Kamoun, L., A Survey of Routing Protocols in Wireless Body Area Networks for Healthcare Applications. International Journal of E-Health and Medical Communications (IJEHMC) 3(2):1–18, 2012.

    Article  Google Scholar 

  4. Rathee, D., Rangi, S., Chakarvarti, S. K. et al., Recent trends in Wireless Body Area Network (WBAN) research and cognition based adaptive WBAN architecture for healthcare. Heal. Technol. 4(3):239–244, 2014.

    Article  Google Scholar 

  5. Tahir, S., Bakhsh, S. T., Alghamdi, R. et al., Fog-Based Healthcare Architecture for Wearable Body Area Network. Journal of Medical Imaging & Health Informatics 7(6):1409–1418, 2017.

    Article  Google Scholar 

  6. Varga, N., Piri, E., and Bokor, L., Network-assisted Smart Access Point Selection for Pervasive Real-time mHealth Applications. Procedia Computer Science 63:317–324, 2015.

    Article  Google Scholar 

  7. Gao, G. P., Hu, B., Wang, S. F. et al., Wearable Circular Ring Slot Antenna With EBG Structure for Wireless Body Area Network. IEEE Antennas & Wireless Propagation Letters 17(3):434–437, 2018.

    Article  Google Scholar 

  8. Gao, G., Hu, B., Tian, X. et al., Experimental study of a wearable aperture-coupled patch antenna for wireless body area network. Microw. Opt. Technol. Lett. 59(4):761–766, 2017.

    Article  Google Scholar 

  9. Gil, I., and Fernándezgarcía, R., Wearable PIFA antenna implemented on jean substrate for wireless body area network. Journal of Electromagnetic Waves & Applications 31(11-12):1–11, 2017.

    Article  Google Scholar 

  10. Sharma, J., Optimised design and development of a bio-medical healthcare device through quality function deployment (QFD). Int. J. Electron. Healthc. 7(1):68–87, 2012.

    Article  Google Scholar 

  11. Arakawa, T., Xie, R., Seshima, F. et al., Air bio-battery with a gas/liquid porous diaphragm cell for medical and health care devices. Biosens. Bioelectron. 103:171–175, 2018.

    Article  CAS  Google Scholar 

  12. Marassi, V., Di, L. C., Smith, S. et al., Silver nanoparticles as a medical device in healthcare settings: a five-step approach for candidate screening of coating agents. R. Soc. Open Sci. 5(1):171113, 2018.

    Article  Google Scholar 

  13. Chaudhari, K., Ukil, A., Kumar, K. N. et al., Hybrid Optimization for Economic Deployment of ESS in PV-Integrated EV Charging Stations. IEEE Transactions on Industrial Informatics 14(1):106–116, 2018.

    Article  Google Scholar 

  14. Pevec, D., Babic, J., Kayser, M. A. et al., A data-driven statistical approach for extending electric vehicle charging infrastructure. Int. J. Energy Res. 42(4):3102–3120, 2018.

    Article  Google Scholar 

  15. Jandak, V., Svec, P., Jiricek, O. et al., Piezoelectric line moment actuator for active radiation control from light-weight structures. Mech. Syst. Signal Process. 96:260–272, 2017.

    Article  Google Scholar 

  16. Malyshevsky, V. S., and Fomin, G. V., Electromagnetic Radiation in the Atmosphere Generated by Excess Negative Charge in a Nuclear-Electromagnetic Cascade. Russ. Phys. J. 59(9):1–6, 2017.

    Article  Google Scholar 

  17. Sambo, Y. A., Héliot, F., and Imran, M. A., A Survey and Tutorial of Electromagnetic Radiation and Reduction in Mobile Communication Systems. IEEE Communications Surveys & Tutorials 17(2):790–802, 2017.

    Article  Google Scholar 

  18. YU, S. et al., Case Analysis and Application of MATLAB Optimized Algorithms (Advanced Version). Beijing: Tsinghua University Press, 2015.

    Google Scholar 

Download references

Acknowledgements

The authors would like to thank the support from the Jiangsu Students’ innovation and entrepreneurship training program (NO.201810333029Y).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yong Jin.

Ethics declarations

Conflict of interest

We declare that we have no conflict of interest.

Human and animal rights

This article does not contain any studies with human participants or animals performed by any of the authors.

Informed consent

Informed consent was obtained from all individual participants included in the study.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

This article is part of the Topical Collection on Mobile & Wireless Health

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jin, Y. Low-Cost and Active Control of Radiation of Wearable Medical Health Device for Wireless Body Area Network. J Med Syst 43, 137 (2019). https://doi.org/10.1007/s10916-019-1254-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s10916-019-1254-0

Keywords

Navigation