Bootstrapped two-electrode biosignal amplifier

  • Technical Note
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

Portable biomedical instrumentation has become an important part of diagnostic and treatment instrumentation. Low-voltage and low-power tendencies prevail. A two-electrode biopotential amplifier, designed for low-supply voltage (2.7–5.5 V), is presented. This biomedical amplifier design has high differential and sufficiently low common mode input impedances achieved by means of positive feedback, implemented with an original interface stage. The presented circuit makes use of passive components of popular values and tolerances. The amplifier is intended for use in various two-electrode applications, such as Holter monitors, external defibrillators, ECG monitors and other heart beat sensing biomedical devices.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

References

  1. Christov I, Dotsinsky I (1988) New approach to the digital elimination of 50 Hz interference from the electrocardiogram. Med Biol Eng Comp 26:431–434

    Article  Google Scholar 

  2. Daskalov I, Dotsinsky I, Christov I (1998) Developments in ECG acquisition, preprocessing, parameter measurement and recording. IEEE Eng Med Biol 17:50–58

    Article  Google Scholar 

  3. Dobrev D (2004) Two-electrode low supply voltage electrocardiogram signal amplifier. Med Biol Eng Comp 42:272–276

    Article  Google Scholar 

  4. Dobrev D, Daskalov I (2002) Two-electrode biopotential amplifier with current-driven inputs. Med Biol Eng Comp 40:122–127

    Article  Google Scholar 

  5. Dobrev D, Neycheva T, Mudrov N (2005) Simple two-electrode biosignal amplifier. Med Biol Eng Comp 43:725–730

    Article  Google Scholar 

  6. Kitchin Ch, Couts L (2006) A designer’s guide to instrumentation amplifiers.chap. 5, 3rd edn. Analog Devices Inc, pp 12–20

  7. Laks M, Arzbaecher R, Bailey J, Geselowitz D, Berson A (1996) Recommendations for safe current limits for electrocardiographs. Circulation 93:837–839

    Google Scholar 

  8. Levkov Ch, Mihov G, Ivanov R, Daskalov I, Christov I, Dotsinsky I (2005) Removal of power-line interference from the ECG: a review of the subtraction procedure. Biomed Eng Online 4:50

    Article  Google Scholar 

  9. Neuman M (1998) Biopotential amplifiers. In: Webster J (ed) Medical instrumentation: applications and design, 3rd edn. Wiley, New York, pp 262–264

  10. Pallas-Areny R, Colominas J, Rosell J (1989) An improved buffer for bioelectric signals. IEEE Trans Biomed Eng 36:490–493

    Article  Google Scholar 

  11. Pallas-Areny R, Webster J (1990) Composite instrumentation amplifier for biopotentials. Ann Biomed Eng 18:251–262

    Article  Google Scholar 

  12. Thakor N, Webster J (1980) Ground-free ECG recording with two electrodes. IEEE Trans Biomed Eng 27:699–704

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dobromir Petkov Dobrev.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Dobrev, D.P., Neycheva, T. & Mudrov, N. Bootstrapped two-electrode biosignal amplifier. Med Biol Eng Comput 46, 613–619 (2008). https://doi.org/10.1007/s11517-008-0312-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-008-0312-4

Keywords

Navigation