Skip to main content
Log in

Estimation of the lactate threshold using an electro acoustic sensor system analysing the respiratory air

  • Technical Note
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

The lactate threshold is used by athletes to optimise the intensity during exercise. It is of interest to measure the threshold on the very day and during the present sport activity. Steady state ergometer tests have been performed on 40 individuals to compare the threshold found by an electro acoustic sensor system to the lactate threshold established by blood analyses evaluated with the Dmax method. The correlation coefficient between the threshold found by the sensor system and the one established by blood analyses regarding workload (Watt), heart rate (beats/min), and lactate level (mmol lactate/l blood) at the thresholds were 0.87 (p < 0.001), 0.74 (p < 0.001), and 0.65 (p < 0.001), respectively. The findings in this study indicates that the thresholds of individuals measured by the sensor system show good correlations to the threshold established with the Dmax method from lactate levels in blood samples.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

References

  1. Alvarenga RL, Souza MN (2007) Estimation of the lactate threshold using bioelectrical impedance spectroscopy: a new noninvasive method. In: Proceedings of the 29th annual international conference of the IEEE EMBS, Lyou, France pp 3052–3055

  2. Billat LV (1996) Use of blood lactate measurements for prediction of exercise performance and for control of training. Sports Med 22(3):157–175

    Google Scholar 

  3. Bishop D, Jenkins DG, Mackinnon LT (1998) The relationship between plasma lactate parameters, Wpeak and 1-h cycling performance in woman. Med Sci Sports Exerc 30(8):1270–1275. doi:10.1097/00005768-199808000-00014

    Article  Google Scholar 

  4. Bosquet L, Léger L, Legros (2002) Methods to determine aerobic endurance. Sports Med 32(11):675–700. doi:10.2165/00007256-200232110-00002

    Article  Google Scholar 

  5. Cheng B, Kuipers H, Snyder AC et al (1992) A new approach for the determination of ventilatory and lactate thresholds. Int J Sports Med 13:518–522

    Google Scholar 

  6. Folke M, Hök B (2008) A new capnograph based on an electro acoustic sensor. Med Biol Eng Comput 46:55–59. doi:10.1007/s11517-007-0228-4

    Article  Google Scholar 

  7. Folke M, Gullstrand L, Hök B (2005) A pilot study to estimate the lactate threshold using an electro acoustic sensor. In: Proceedings of the 13th Nordic-Baltic conference on biomedical engineering and medical physics. Umeå, Sweden pp 249–250

  8. Ivy JL, Costill DL, van Handel PJ et al (1981) Alteration in lactate threshold with changes in substrate availability. Int J Sports Med 2:139–142

    Google Scholar 

  9. Karapetian GK, Engels HJ, Gretebeck RJ (2008) Use of heart rate variability to estimate LT and VT. Int J Sports Med. doi:10.1055/s-2007-989423

    Google Scholar 

  10. Loat CER, Rhodes EC (1993) Relationship between the lactate and ventilatory thresholds during prolonged exercise. Sports Med 15(2):104–115

    Google Scholar 

  11. Plato PA, McNulty M, Crunk SM et al (2008) Predicting lactate threshold using ventilatory threshold. Int J Sports Med. doi:10.1055/s-2007-989453

    Google Scholar 

  12. Stegmann H, Kindermann W (1982) Comparison of prolonged exercise test at the individual anaerobic threshold and the fixed anaerobic threshold of 4 mmol-1 lactate. Int J Sports Med 3:105–110

    Article  Google Scholar 

  13. Svedahl K, MacIntosh BR (2003) Anaerobic threshold: the concept and methods of measurement. Can J Appl Physiol 28(2):299–323

    Google Scholar 

  14. Urhausen A, Coen B, Weiler B et al (1993) Individual anaerobic threshold and maximum lactate steady state. Int J Sports Med 14:134–139

    Google Scholar 

  15. Wasserman K (1994) Coupling of an external to cellular respiration during exercise: the wisdom of the body revisited. Am J Physiol 226(29):519–539

    Google Scholar 

  16. Wasserman K, Beaver WL, Whipp BJ (1990) Gas exchange theory and the lactic acidosis (anaerobic) threshold. Circulation 81(1 Suppl II):14–30

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Folke.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Folke, M. Estimation of the lactate threshold using an electro acoustic sensor system analysing the respiratory air. Med Biol Eng Comput 46, 939–942 (2008). https://doi.org/10.1007/s11517-008-0373-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-008-0373-4

Keywords

Navigation