Rotating permanent magnet excitation for blood flow measurement

  • Original Article
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

A compact, portable and improved blood flow measurement system for an extracorporeal circuit having a rotating permanent magnetic excitation scheme is described in this paper. The system consists of a set of permanent magnets rotating near blood or any conductive fluid to create high-intensity alternating magnetic field in it and inducing a sinusoidal varying voltage across the column of fluid. The induced voltage signal is acquired, conditioned and processed to determine its flow rate. Performance analysis shows that a sensitivity of more than 250 mV/lpm can be obtained, which is more than five times higher than conventional flow measurement systems. Choice of rotating permanent magnet instead of an electromagnetic core generates alternate magnetic field of smooth sinusoidal nature which in turn reduces switching and interference noises. These results in reduction in complex electronic circuitry required for processing the signal to a great extent and enable the flow measuring device to be much less costlier, portable and light weight. The signal remains steady even with changes in environmental conditions and has an accuracy of greater than 95 %. This paper also describes the construction details of the prototype, the factors affecting sensitivity and detailed performance analysis at various operating conditions.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Barnes CW (1960) A new method for obtaining flow signals from the electromagnetic flow meter. Naturwissenschaften 47(3):56–57

    Article  Google Scholar 

  2. Donati S (2004) Electro-optical instrumentation: sensing and measuring with lasers. Pearson Education, New York

    Google Scholar 

  3. Gill RW (1985) Measurement of blood flow by ultrasound: accuracy and sources of error. Ultrasound Med Biol 11(4):625–641

    Article  CAS  PubMed  Google Scholar 

  4. Hartley CJ, Cole JS (1974) An ultrasonic pulsed Doppler system for measuring blood flow in small vessels. J Appl Physiol 37(4):626–629

    CAS  PubMed  Google Scholar 

  5. Hickman R, Crosier JH, Smith P, Immelman EJ, Terblanche J (1975) Problems with an electromagnetic blood flowmeter. S Afr Med J 49:261–264

    CAS  PubMed  Google Scholar 

  6. Koelink MH, De Mul FFM, Weijers AL, Greve J, Graaff R, Dassel ACM, Aarnoudse JG (1994) Fiber-coupled self-mixing diode-laser Doppler velocimeter: technical aspects and flow velocity profile disturbances in water and blood flows. Appl Opt 33(24):5628–5641

    Article  CAS  PubMed  Google Scholar 

  7. Kolin A (1936) An electromagnetic flowmeter. Principle of the method and its application to bloodflow measurements. Exp Biol Med 35(1):53–56

    Article  Google Scholar 

  8. Lund-Johansen P (1990) The dye dilution method for measurement of cardiac output. Eur Heart J 11(suppl I):6–12

    Article  PubMed  Google Scholar 

  9. Nair SS, Nagesh DS (2015) Design of electromagnetic probe having reduced base line drift for blood flow measurement. IETE J Res 61(3) [Epub ahead of print]

  10. Norgia M, Pesatori A, Rovati L (2010) Low-cost optical flowmeter with analog front-end electronics for blood extracorporeal circulators. IEEE Trans Instrum Meas 59(5):1233–1239

    Article  Google Scholar 

  11. Pesatori A, Norgia M, Rovati L (2009) Optical flowmeter for blood extracorporeal circulators. In: Instrumentation and Measurement Technology Conference. IEEE, pp. 1759–1762

  12. Renal Research Institute (2012) Effect of sodium concentration of priming and rinsing fluids on inter dialytic weight gain and blood pressure in hemo dialysis patients: a prospective pilot study, NCT01168947

  13. Rhode KS, Lambrou T, Hawkes DJ, Seifalian AM (2005) Novel approaches to the measurement of arterial blood flow from dynamic digital X-ray images. IEEE Trans Med Imaging 24(4):500–513

    Article  PubMed  Google Scholar 

  14. Spencer MP, Denison AB (1959) The square-wave electromagnetic flowmeter: theory of operation and design of magnetic probes for clinical and experimental applications. IRE Trans Med Electron 4:220–228

    Article  Google Scholar 

  15. Vatner SF, Franklin DEAN, VanCitters RL (1970) Simultaneous comparison and calibration of the Doppler and electromagnetic flowmeters. J Appl Physiol 29(6):907–910

    CAS  PubMed  Google Scholar 

  16. Webster JG (ed) (1999) Chapter V, Mechanical variables measurement-fluids, the measurement, instrumentation, and sensors: handbook. IEEE press, New York, pp 28.64–28.77. ISBN 0-8493-8347-1

    Google Scholar 

  17. Wyatt DG (1961) Problems in the measurement of blood flow by magnetic induction. Phys Med Biol 5(4):369

    Article  CAS  PubMed  Google Scholar 

  18. Wyatt DG (1961) Zero error in induction flowmeters employing a permanent magnet. Phys Med Biol 5(4):449

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sarath S. Nair.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nair, S.S., Vinodkumar, V., Sreedevi, V. et al. Rotating permanent magnet excitation for blood flow measurement. Med Biol Eng Comput 53, 1187–1199 (2015). https://doi.org/10.1007/s11517-015-1310-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-015-1310-y

Keywords

Navigation