Development and placement accuracy evaluation of an MR conditional robot for prostate intervention

  • Original Article
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

Robot-assisted prostate intervention under magnetic resonance imaging (MRI) guidance is a promising method to improve the clinical performance compared with the manual method. An MR conditional 6-DOF prostate intervention serial robot is developed and a binocular vision system (BVS) is established to evaluate the needle placement accuracy and located the penetration point precisely. The robot is designed by the MR conditional criteria. The serial configuration of the robot provides adequate flexibility and large workspace and excellent friendliness to the physicians. The kinematics are deduced and the needle placement control flow is proposed according to the configuration of the robot. The robot-assisted prostate intervention is divided into two phases including needle placement and needle penetration. A custom-made robust BVS is developed to obtain the needle tip position automatically in the needle placement phase where the needle cannot be detected by the MRI for lack of hydrogen atom. A simple and general algorithm used for needle tip camera coordinate estimation is proposed. Experiments on the BVS validation and robot accuracy evaluation are performed. The experiment results show that the errors of the BVS are under 0.3621 mm and the position error of the proposed robot is 2.815 mm which indicate the adequate accuracy for the prostate intervention.

Graphical abstract

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

References

  1. Bray F, Ferlay J, Soerjomataram I (2018) Global cancer statistics 2018: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. A Cancer Journal for Clinicians, CA

    Google Scholar 

  2. Terris MK, Wallen EM, Stamey TA (1997) Comparison of mid-lobe versus lateral systematic sextant biopsies in the detection of prostate cancer. Urol Int 59(4):239–242

    Article  CAS  Google Scholar 

  3. Goldenberg AA, Trachtenberg J, Yi Y (2010) Robot-assisted MRI-guided prostatic interventions. Robotica 28(02):215–234

    Article  Google Scholar 

  4. Krieger A, Song S, Cho NB (2013) Development and evaluation of an actuated MRI-compatible robotic system for MRI-guided prostate intervention. IEEE/ASME Trans Mechatronics 18(1):273–284

    Article  Google Scholar 

  5. Erwin A, O'Malley MK, Ress D (2017) Kinesthetic feedback during 2DOF wrist movements via a novel MR-compatible Robot. IEEE Trans Neural Syst Rehabil Eng 25(9):1489–1499

    Article  Google Scholar 

  6. Jiang S, Lou J, Sun F (2015) Modeling and control of a high-precision tendon-based magnetic resonance imaging–compatible surgical robot. Proc Inst Mech Eng Part I: J Syst Control Eng 229(8):711–727

    Google Scholar 

  7. Yang B, Tan U, McMillan AB (2011) Design and Control of a 1-DOF MRI-compatible pneumatically actuated robot with long transmission lines. IEEE/ASME Trans Mechatronics 16(6):1040–1048

    Article  Google Scholar 

  8. Su H, Shang W, Cole G (2015) Piezoelectrically actuated robotic system for MRI-guided prostate percutaneous therapy. IEEE/ASME Trans Mechatronics 20(4):1920–1932

    Article  Google Scholar 

  9. Shi Y, Li Y, Zhao C (2011) A new type butterfly-shaped transducer linear ultrasonic motor. J Intell Mater Syst Struct 22(6):567–575

    Article  Google Scholar 

  10. Zhao C. Ultrasonic motors: technologies and applications: Springer Science & Business Media; 2011.

  11. Yu N, Gassert R, Riener R (2011) Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging. Int J Comput Assist Radiol Surg 6:473–488

    Article  Google Scholar 

  12. Lin Q, Cai K, Yang R (2016) Development and validation of a near-infrared optical system for tracking surgical instruments. J Med Syst 40(4)

  13. Luo Z, Zhang K, Wang Z (2017) 3D pose estimation of large and complicated workpieces based on binocular stereo vision. Appl Opt 56(24):6822–6836

    Article  Google Scholar 

  14. Xiang R, He W, Zhang X (2018) Size measurement based on a two-camera machine vision system for the bayonets of automobile brake pads. Measurement 122(106-16)

  15. Lin Y, Shi Y, Zhang J, Wang F, Sun H (2020) Design and evaluation of a needle tip measurement system based on binocular vision. Metrol Meas Syst 27(3):495–512

    Google Scholar 

  16. Stamey TA, Mcneal JE, Freiha FS (1988) Morphometric and clinical studies on 68 consecutive radical prostatectomies. J Urol 139(6):1235–1240

    Article  CAS  Google Scholar 

  17. Stamey TA, Freiha FS, Mcneal JE (2015) Localized prostate cancer. Relationship of tumor volume to clinical significance for treatment of prostate cancer. Cancer 71(S3):933–938

    Article  Google Scholar 

  18. Shokrollahi P, Drake JM, Goldenberg AA (2017) Signal-to-noise ratio evaluation of magnetic resonance images in the presence of an ultrasonic motor. Biomed Eng Online 16:45

    Article  Google Scholar 

  19. Shokrollahi P, Drake JM, Goldenberg AA (2017) Ultrasonic motor-induced geometric distortions in magnetic resonance images. Med Biol Eng Comput

  20. Lin Y., Shi Y. and Zhang J., Design and control of a piezoelectric actuated prostate intervention robotic system. 17th International Conference on Ubiquitous Robots (UR), Kyoto, Japan, 175-180, 2020.

  21. Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22(11):1330–1334

    Article  Google Scholar 

Download references

Funding

This work was supported by the National Natural Sciences Foundation of China (No. 51975282).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yunlai Shi.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lin, Y., Shi, Y., Wang, F. et al. Development and placement accuracy evaluation of an MR conditional robot for prostate intervention . Med Biol Eng Comput 59, 1023–1034 (2021). https://doi.org/10.1007/s11517-021-02347-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-021-02347-5

Keywords

Navigation