Purpose

Robotics may improve vitreoretinal surgery by steadying hand motion, thereby reducing negative outcomes. This study aimed to develop a microsurgical robot for vitreoretinal surgery and to perform clinical procedures using robot-assisted interventions.

Methods

A microsurgical system for vitreoretinal surgery was designed to meet specific requirements for the degree of freedom, accuracy, and workspace. The system was intended to provide micrometer accurate manipulation within the eye. The slave manipulator has a tool change mechanism for switching surgical instruments. The slave manipulator is controlled by the surgeon using a master manipulator consisting of multiple joints.

Results

The robotic system was used to carry out microcannulation experiments on a pig’s eye. A surgeon was able to successfully perform microcannulation.

Conclusions

This microsurgical robotic vitreoretinal surgical system showed superior operability compared with a traditional manual procedure, and it demonstrated sufficient potential to warrant further testing in animal trials to assess its clinical feasibility.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ang WT et al (2001) Design and implementation of active error canceling in a hand-held microsurgicak instrument. In: Proceedings of IEEE IROS, pp 1106–1111

  2. Singhy SPN et al (2002) Physiological tremor amplitude during retinal microsurgery. In: Proceedings of the IEEE 28th Annual Northeast Bioengineering, pp 171–172

  3. Mitchell B et al (2007) Development and application of a new steady-hand manipulator for retinal surgery. In: Proceedings of IEEE ICRA, pp 623–629

  4. Taylor R et al (1999) A steady-hand robotic system for microsurgical augmentation. Int J Robot Res 18(12): 1201–1210

    Article  Google Scholar 

  5. Fleming I et al (2008) Cooperative robot assistant for retinal microsurgery. Lect Notes Comput Sci 5242: 543–550

    Article  Google Scholar 

  6. Iordachita I et al (2009) A sub-millimetric, 0.25 mN resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery. Int J CARS 4(4): 383–390

    Article  Google Scholar 

  7. Uneri A et al (2010) New steady-hand eye robot with micro-force sensing for vitreoretinal surgery. In: Proceedings of IEEE BioRob, pp 814–819

  8. Balicki M et al (2010) Micro-force sensing in robot assisted membrane peeling for vitreoretinal surgery. Lect Notes Comput Sci 6363: 303–310

    Article  Google Scholar 

  9. Riviere CN et al (2003) Toward active tremor canceling in handheld microsurgical instruments. IEEE Trans Robot Autom 19(5): 793–800

    Article  Google Scholar 

  10. Choi DY et al (2005) Flexure-based manipulator for active handheld microsurgical instrument. In: Proceedings of the IEEE 27th Annual EMBS, pp 2325–2328

  11. Das H et al (1999) Evaluation of a telerobotic system to assist surgeons in microsurgery. Comput Aided Surg 4(1): 15–25

    Article  PubMed  CAS  Google Scholar 

  12. Das H et al (1996) Telerobotic for microsurgery. In: Proceedings of the IEEE 18th Annual EMBS, pp 227–228

  13. Charles S et al (1997) Dexterity-enhanced telerobotic microsurgery. In: Proceedings of IEEE ICRA, pp 5–10

  14. Roux PDL et al (2001) Robot-assisted microsurgery: a feasibility study in the rat. Neurosurgery 48(3): 584–589

    Article  PubMed  Google Scholar 

  15. Nakano T et al (2009) A parallel robot to assist vitreoretinal surgery. Int J CARS 4(6): 517–526

    Article  Google Scholar 

  16. Takahashi H et al (2008) Master manipulator with higher operability designed for micro neuro surgical system. In: Proceedings of IEEE ICRA, pp 3902–3907

  17. Weiss JN et al (2001) Injection of tissue plasminogen activator into a branch retinal vein in eyes with central retinal vein occlusion. Ophthalmology 108(12): 2249–2257

    Article  PubMed  CAS  Google Scholar 

  18. Bynoe LA et al (2005) Retinal endovascular surgery for central retinal vein occlusion: initial experience of four surgeons. Retina 25(5): 625–632

    Article  PubMed  Google Scholar 

  19. Feltgen N et al (2006) Retinal endovascular lysis in ischemic central retinal vein occlusion. One-year results of a pilot study. Ophthalmology 114(4): 716–723

    Article  PubMed  Google Scholar 

  20. Weiss JN (2008) Retinal endovascular lysis. Ophthalmology 115(1): 216–217

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoshiki Ida.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ida, Y., Sugita, N., Ueta, T. et al. Microsurgical robotic system for vitreoretinal surgery. Int J CARS 7, 27–34 (2012). https://doi.org/10.1007/s11548-011-0602-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11548-011-0602-4

Keywords

Navigation