Abstract
Purpose
Hemodynamic simulations are of increasing interest for the assessment of aneurysmal rupture risk and treatment planning. Achievement of accurate simulation results requires the usage of several patient-individual boundary conditions, such as a geometric model of the vasculature but also individualized inflow conditions.
Methods
We propose the automatic estimation of various parameters for boundary conditions for computational fluid dynamics (CFD) based on a single 3D rotational angiography scan, also showing contrast agent inflow. First the data are reconstructed, and a patient-specific vessel model can be generated in the usual way. For this work, we optimize the inflow waveform based on two parameters, the mean velocity and pulsatility. We use statistical analysis of the measurable velocity distribution in the vessel segment to estimate the mean velocity. An iterative optimization scheme based on CFD and virtual angiography is utilized to estimate the inflow pulsatility. Furthermore, we present methods to automatically determine the heart rate and synchronize the inflow waveform to the patient’s heart beat, based on time–intensity curves extracted from the rotational angiogram. This will result in a patient-individualized inflow velocity curve.
Results
The proposed methods were evaluated on two clinical datasets. Based on the vascular geometries, synthetic rotational angiography data was generated to allow a quantitative validation of our approach against ground truth data. We observed an average error of approximately \(5.7\,\%\) for the mean velocity, \(7.1\,\%\) for the pulsatility. The heart rate was estimated very precisely with an average error of about \(0.8\,\%\), which corresponds to about 6 ms error for the duration of one cardiac cycle. Furthermore, a qualitative comparison of measured time–intensity curves from the real data and patient-specific simulated ones shows an excellent match.
Conclusion
The presented methods have the potential to accurately estimate patient-specific boundary conditions from a single dedicated rotational scan.
Similar content being viewed by others
References
Bögel M, Hölter P, Redel T, Maier A, Hornegger J, Dörfler A. (2015) A fully-automatic locally adaptive thresholding algorithm for blood vessel segmentation in 3D digital subtraction angiography. In: Engineering in Medicine and Biology Society (EMBC), 2015 37th annual international conference of the IEEE, pp 2006–2009
Bonnefous O, Pereira V, Ouared R, Brina O, Aerts H, Hermans R, van Nijnatten F, Stawiaski J, Ruijters D (2012) Quantification of arterial flow using digital subtraction angiography. Med Phys 39(10):6264–6275
Cebral JR, Radaelli A, Frangi A, Putman CM (2007) Qualitative comparison of intra-aneurysmal flow structures determined from conventional and virtual angiograms. In: Medical imaging, pp 65,111E–65,111E. International Society for Optics and Photonics
Davis B, Royalty K, Kowarschik M, Rohkohl C, Oberstar E, Aagaard-Kienitz B, Niemann D, Ozkan O, Strother C, Mistretta C (2013) 4D digital subtraction angiography: implementation and demonstration of feasibility. Am J Neuroradiol 34(10):1914–1921
Durant J, Waechter I, Hermans R, Weese J, Aach T (2008) Toward quantitative virtual angiography: evaluation with in vitro studies. In: Biomedical imaging: from nano to macro, 2008. ISBI 2008. 5th IEEE international symposium on, pp 632–635
Endres J, Kowarschik M, Redel T, Sharma P, Mihalef V, Hornegger J, Dörfler A (2012) A workflow for patient-individualized virtual angiogram generation based on CFD simulation. Comput Math Methods Med 2012(306765):1–24
Endres J, Redel T, Kowarschik M, Hutter J, Hornegger J, Dörfler A (2012) Virtual angiography using CFD simulations based on patient-specific parameter optimization. In: IEEE (ed.) International symposium on biomedical imaging (ISBI), pp 1200–1203
Endres J, Rohkohl C, Schafer S, Royalty K, Maier A, Kowarschik M, Hornegger J (2015) 4D DSA iterative reconstruction. In: King M, Glick S, Mueller K (eds) Proceedings of the fully3D, pp 276–279
Ford MD, Stuhne GR, Nikolov HN, Habets DF, Lownie SP, Holdsworth DW, Steinman D (2005) Virtual angiography for visualization and validation of computational models of aneurysm hemodynamics. Med Imaging, IEEE Trans 24(12):1586–1592
Gülsün M, Tek H (2008) Robust vessel tree modeling. In: Ayache N, Delingette H, Golland P, Mori K (eds) Medical image computing and computer-assisted intervention—MICCAI. Springer, Heidelberg, pp 602–611
Huang T, Wu T, Lin C, Mok G, Guo W (2012) Peritherapeutic quantitative flow analysis of arteriovenous malformation on digital subtraction angiography. J Vasc Surg 56(3):812–815
Karmonik C, Klucnik R, Benndorf G (2008) Blood flow in cerebral aneurysms: comparison of phase contrast magnetic resonance and computational fluid dynamics-preliminary experience. Rofo 180(3):209–215
Sun Q, Groth A, Bertram M, Waechter I, Bruijns T, Hermans R, Aach T (2010) Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms. Med Phys 37(9):5054–5065
Sun Q, Groth A, Waechter I, Brina O, Weese J, Aach T (2009) Quantitative evaluation of virtual angiography for interventional X-ray acquisitions. In: 2009 IEEE international symposium on biomedical imaging: from nano to macro: [ISBI ’09], IEEE, 2009, Boston, pp 895–898
Wächter I, Bredno J, Hermans R, Weese J, Barrat D, Hawkes D (2008) Model-based blood flow quantification from rotational angiography. Med Image Anal 12(5):586–602
Acknowledgments
The authors gratefully acknowledge funding of the Erlangen Graduate School in Advanced Optical Technologies (SAOT) by the German Research Foundation (DFG) in the framework of the German excellence initiative.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
S. Gehrisch, T. Redel and M. Kowarschik are employees of Siemens Healthcare GmbH.
Ethical approval
This study has been performed retrospectively. Formal consent is not required.
Informed consent
For this type of study, formal consent is not required.
Additional information
Disclaimer The concepts and information presented in this paper are based on research and are not commercially available.
Rights and permissions
About this article
Cite this article
Boegel, M., Gehrisch, S., Redel, T. et al. Patient-individualized boundary conditions for CFD simulations using time-resolved 3D angiography. Int J CARS 11, 1061–1069 (2016). https://doi.org/10.1007/s11548-016-1367-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11548-016-1367-6