Skip to main content
Log in

Assessment of bilateral filter on low NEX open MRI views

  • Original Paper
  • Published:
Signal, Image and Video Processing Aims and scope Submit manuscript

Abstract

Purpose: A bilateral filter (BF) has the property of de-noising digital images while preserving edges. This paper investigates the impact of selecting the BF variables in order to diminish the deterioration of SNR due to reducing the number of excitations (NEX) per image in magnetic resonance imaging (MRI) technique. The paper studies the behavior of the BF on the axial, sagittal, and coronal MRI orientations acquired by spin echo (SE), turbo spin echo (TSE), and the fluid attenuated inversion recovery (FLAIR) pulse sequences from an open MRI device. Method: a set of MRI head images where acquired at different NEXs. The BF was applied at various values of window sizes, filter domains, and filter ranges. The comparison between the high NEX and the BF low NEX MR images was calculated using the peak signal-to-noise ratio (PSNR), the mean-square error (MSE), and the normalized absolute error (NAE). Results: Numerically, the BF is able to achieve up to 29, 44, and 59 % noise suppression from the T2 axial, T1 sagittal, and coronal MR views, respectively. Conclusions: The BF can successfully compensate a part of the SNR decrease due to reduce NEX. The behavior of the BF varies with the type of MR view and the type of pulse sequence. The BF is a successful tool to enhance the appearance of low NEX MR images acquired from open MR devices. This means that BF can contribute in shortening the MRI scan time.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9

Similar content being viewed by others

References

  1. Manjon, J.V., Caballero, J.C., Lull, J.J., Marti, G.G., Bonmati, L.M., Robles, M.: MRI denoising using non-local means. Med. Image Anal. 12, 514–523 (2008)

    Article  Google Scholar 

  2. Kumar, V., Saini, S., Dhiman, S.: Quality improvement on MRI corrupted with Rician noise using wave atom transform. Int. J. Comput. Appl. 37, 28–32 (2012)

    Google Scholar 

  3. Anand, C.S., Sahambi, J.S.: Wavelet domain non-linear filtering for MRI denoising. Magn. Reson. Imaging 28, 842–861 (2011)

    Article  Google Scholar 

  4. Arif, A.S., Mansor, S., Logeswaran, R.: Combined bilateral and anisotropic-diffusion filters for medical image de-noising. Presented at the IEEE Student Conference on Research and Development, Malaysia (2011)

  5. Rydell, J., Knutsson, H., Borga, M.: Bilateral filtering of fMRI data. IEEE J. Sel. Topics Signal Process. 2, 891–896 (2008)

    Article  Google Scholar 

  6. Walker, S.A., Miller, D., Tanabe, J.: Bilateral spatial filtering: refining methods for localizing brain activation in the presence of parenchymal abnormalities. NeuroImage 33, 564–569 (2006)

    Article  Google Scholar 

  7. Hamarneh, G., Hradsky, J.: Bilateral filtering of diffusion tensor magnetic resonance images. IEEE Trans. Image Process. 16, 2463–2475 (2007)

    Article  MathSciNet  Google Scholar 

  8. Hwang, J., Han, Y., Park, H.W.: Segmentation of brain parenchyma using bilateral filtering and region growing. In: Proceedings of the \(29^{\rm th}\) Annual International Conference of the IEEE Engineering in Medicine and Biology Society EMBS, France, pp. 6263–6266, 23–26 August 2007

  9. Gal, Y., Mehnert, A.J.H., Bradley, A.P., McMahon, K., Kennedy, D., Crozier, S.: Denoising of dynamic contrast-enhanced MR images using dynamic nonlocal means. IEEE Trans. Med. Imaging 29, 302–310 (2010)

    Article  Google Scholar 

  10. McPhee, K.C., Denk, C., Al-Rekabi, Z., Rauscher, A.: Bilateral filtering of magnetic resonance phase images. Magn. Reson. Imaging 29, 1023–1029 (2011)

    Google Scholar 

  11. Yang, X., Fei, B.A.: MR brain classification method based on multiscale and multiblock fuzzy C-means, Presented at the \(5^{\rm th}\) International Conference on Bioinformatics and Biomedical Engineering (iCBBE), USA, May 10–12 (2012)

  12. Tomasi, C., Manduchi, R.: Bilateral filtering for gray and color images. In: Proceedings of the IEEE International Conference on Computer Vision, India, pp. 839–846, Jan 4–7 (1998)

  13. Elad, M.: On the origin of the bilateral Filter and ways to improve it. IEEE Trans. Image Process. 11, 1141–1151 (2002)

    Article  MathSciNet  Google Scholar 

  14. Barash, D.: Fundamental relationship between bilateral filtering, adaptive smoothing, and the nonlinear diffusion equation. IEEE Trans. Pattern Anal. Mach. Intell. 24, 844–847 (2002)

    Article  Google Scholar 

  15. Grgic, S., Grgic, M., Mrak, M.: Reliability of objective picture quality measures. J. Electr. Eng. 55, 3–10 (2004)

    Google Scholar 

  16. Verma, A., Sharma, B.: Comparative analysis in medical imaging. Int. J. Comput. Appl. 1, 87–92 (2010)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Abdel Razzak Al-Hinnawi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Al-Hinnawi, A.R., Daear, M. Assessment of bilateral filter on low NEX open MRI views. SIViP 9, 9–17 (2015). https://doi.org/10.1007/s11760-012-0417-y

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11760-012-0417-y

Keywords

Navigation