Skip to main content
Log in

aTUG: technical apparatus for gait and balance analysis within component-based Timed Up & Go using mutual ambient sensors

  • Original Research
  • Published:
Journal of Ambient Intelligence and Humanized Computing Aims and scope Submit manuscript

Abstract

A novel approach to instrumenting the Timed Up & Go (TUG) assessment test and to performing a detailed mobility analysis during the test in professional and domestic environments is presented. The approach, called aTUG, is based on the usage of ambient sensor technologies i.e. a light barrier, four force sensors, and a laser range scanner built into a single apparatus. aTUG supports execution and documentation of traditional TUG and enhanced component-based TUG and computes several spatio-temporal parameters of gait and balance. aTUG defines five components: Standing up, walking there, turning, walking back, and sitting down. Algorithms for detection of those components, for computation of their durations and the duration of the whole TUG, and for detailed gait and balance analysis based on available sensor data are presented. An experiment with five elderly patients aged 74–91 years has been conducted in a residential care facility in Oldenburg, Germany. Results of the experiment show that aTUG can reliably and precisely measure total duration of TUG and durations of the single components with a mean error of only 0.05 s and mean standard deviation of 0.59 s using especially its force and range measurements. Initial results of gait and balance analysis are presented and challenges regarding application of the approach is domestic environments are outlined.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  • Baumgartner T, Fekete SP, Kamphans T, Kröller A, Pagel M, Gietzelt M, Haux R (2011) Demo abstract: using a sensor network to enhance a standardized medical test. In: Marrón PJ, Whitehouse K (eds) EWSN, volume 6567 of Lecture Notes in Computer Science. Springer, New York

  • Beers MH, Berkow R (eds) (2006) The Merck manual of geriatrics. Merck & Co., Inc. http://www.merck.com/mkgr/mmg/home.jsp

  • Böhm K, Tesch-Rmer C, Ziese T (2008) Gesundheit und Krankheit im Alter. Online. ISBN 978-3-89606-196-6

  • Botolfsen P, Helbostad JL, Moe-Nilssen R, Wall JC (2008) Reliability and concurrent validity of the expanded timed up-and-go test in older people with impaired mobility. Physiother Res Int 13(2):94–106

    Article  Google Scholar 

  • Boulic R, Thalmann NM, Thalmann D (1990) A global human walking model with real-time kinematic personification. Vis Comput 6:344–358. ISSN 0178-2789

    Google Scholar 

  • International Classification (2007) The WHO, and The ICF. WHO International Classification of Functioning, Disability and Health (ICF). http://www.who.int/classifications/icf/en/

  • Dietermayer (2001) Model based object classification and object tracking in traffic scenes from range images

  • Frenken T, Gövercin M, Mersmann S, Hein A (2010) Precise assessment of self-selected gait velocity in domestic environments. In: Pervasive computing technologies for healthcare (PervasiveHealth). IEEE. ISBN 978-963-9799-89-9

  • Frenken T, Isken M, Volkening N, Brell M, Hein A (2012) Criteria for quality and safety while performing unobtrusive domestic mobility assessments using mobile service robots. In: Proceedings 5. Deutscher Kongress, Ambient Assisted Living. VDE Verlag

  • Frenken T, Wilken O, Hein A (2010) Technical approaches to unobtrusive geriatric assessments in domestic environments. In: Aghajan H, Gottfried B (eds) Proceedings of the 5th workshop on behaviour monitoring and interpretation, BMI’10, Karlsruhe, Germany. volume 678 of CEUR Workshop Proceedings, pp 63–74. CEUR-WS.org

  • Fuerstenberg KC, Dietmayer K (2004) Object tracking and classification for multiple active safety and comfort applications using a multilayer laser scanner. In: Intelligent vehicles symposium, pp 802–807

  • Greene BR, Donovan AO, Romero-Ortuno R, Cogan L, Ni Scanaill C, Kenny RA (2010) Quantitative falls risk assessment using the timed up and go test. IEEE Trans Biomed Eng 57(12):2918–2926

    Google Scholar 

  • Helmer A, Lipprandt M, Frenken T, Eichelberg M, Hein A (2011) 3DLC: a comprehensive model for personal health records supporting new types of medical applications. J Healthcare Eng 2:321–336. ISSN 2030-2295. doi:10.1260/2040-2295.2.3.321

  • Higashi Y, Yamakoshi K, Fujimoto T, Sekine M, Tamura T (2008) Quantitative evaluation of movement using the timed up-and-go test. Eng Med Biol Mag IEEE 27(4):38–46, 2008. ISSN 0739-5175

    Google Scholar 

  • Kalgaonkar K, Raj B (2007) Acoustic Doppler sonar for gait recognition. In: Advanced video and signal based surveillance. IEEE Conference on AVSS 2007, pp 27–32

  • Kamiya K, Kudo M, Nonaka H, Toyama J (2008) Sitting posture analysis by pressure sensors. In: Pattern recognition. 19th international conference on ICPR 2008, pp 1–4

  • Karlsson A, Frykberg G (2000) Correlations between force plate measures for assessment of balance. Clin Biomech 15(5):365–369. ISSN 0268-0033

    Google Scholar 

  • Knight H, Lee JK, Ma H (2008) Chair alarm for patient fall prevention based on gesture recognition and interactivity. In: Engineering in Medicine and Biology Society. EMBS 2008. 30th annual international conference of the IEEE, pp 3698–3701

  • Large J, Gan N, Basic D, Jennings N (2006) Using the timed up and go test to stratify elderly inpatients at risk of falls. Clin Rehabil 20(5):421–428

    Article  Google Scholar 

  • Mahoney FI, Barthel DW (1965) Functional evaluation: the Barthel index. Md State Med J 14:61–65

    Google Scholar 

  • Marschollek M, Nemitz G, Gietzelt M, Wolf KH, Meyer zu SH, Haux R (2009) Predicting in-patient falls in a geriatric clinic. Zeitschrift fr Gerontologie und Geriatrie 42:317–322. ISSN 0948-6704. doi:10.1007/s00391-009-0035-7

    Google Scholar 

  • Mathias S, Nayak US, Isaacs B (1986) Balance in elderly patients: the “get-up and go” test. Arch Phys Med Rehabil 67(6):387–389

    Google Scholar 

  • Medley A, Thompson M (1997) The effect of assistive devices on the performance of community dwelling elderly on the timed up and go test. Issues Aging 20:3–7

    Google Scholar 

  • Morris S, Morris ME, Iansek R (2001) Reliability of measurements obtained with the timed ”Up & Go” test in people with Parkinson disease. Phys Ther 81(2):810–818

    Google Scholar 

  • Narayanan MR, Redmond SJ, Scalzi ME, Lord SR, Celler BG, Lovell Ast NH (2010) Longitudinal falls-risk estimation using triaxial accelerometry. IEEE Trans Biomed Eng 57(3):534–541

    Article  Google Scholar 

  • Pallej T, Teixid M, Tresanchez M, Palacn J (2009) Measuring gait using a ground laser range sensor. Sensors 9(11):9133–9146. ISSN 1424-8220

    Google Scholar 

  • Perry J (1992) Gait analysis: normal and pathological function. Delmar Learning, 1st edn. ISBN 1556421923

  • Podsiadlo D, Richardson S (1991) The timed ”Up & Go”: a test of basic functional mobility for frail elderly persons. J Am Geriatr Soc 39(2):142–148

    Google Scholar 

  • Qian G, Zhang J, Kidan A (2008) People identification using gait via floor pressure sensing and analysis. In: Roggen D, Lombriser C, Trster G, Kortuem G, Havinga P (eds) Smart sensing and context, volume 5279 of Lecture Notes in Computer Science. Springer, Berlin, pp 83–98. ISBN 978-3-540-88792-8

  • Salarian A, Horak FB, Zampieri C, Carlson-Kuhta P, Nutt JG, Aminian K (2010) iTUG, a sensitive and reliable measure of mobility. IEEE Trans Neural Syst Rehabil Eng 18(3):303–310

    Article  Google Scholar 

  • Scanaill CN, Carew S, Barralon P, Noury N, Lyons D, Lyons GM (2006) A review of approaches to mobility telemonitoring of the elderly in their living environment. Ann Biomed Eng 34(4):547–563

    Article  Google Scholar 

  • Shao X, Zhao H, Nakamura K, Katabira K, Shibasaki R, Nakagawa Y (2007) Detection and tracking of multiple pedestrians by using laser range scanners. In: Intelligent robots and systems. IEEE/RSJ international conference on IROS 2007, pp 2174 –2179

  • Spehr J, Gietzelt M, Wegel S, Kltzsch Y, Winkelbach S, Marschollek M, Gvercin M, Wahl F, Haux R, Steinhagen-Thiessen E (2011) Vermessung von Gangparametern zur Sturzprdikation durch Vision- und Beschleunigungssensorik. In: Demographischer Wandel—Assistenzsysteme aus der Forschung in den Markt (AAL 2011)

  • Stone EE, Skubic M (2011) Evaluation of an inexpensive depth camera for passive in-home fall risk assessment. In: 5th international conference on pervasive computing technologies for healthcare (PervasiveHealth)

  • Tahmoush D, Silvious J (2009) Radar micro-doppler for long range front-view gait recognition. In: Biometrics: theory, applications, and systems. IEEE 3rd international conference on BTAS ’09, pp 1 –6

  • Wall JC, Bell C, Campbell S, Davis J (2000) The timed get-up-and-go test revisited: measurement of the component tasks. J Rehabil Res Dev 37(1):109–113

    Google Scholar 

  • Weiss A, Herman T, Plotnik M, Brozgol M, Giladi N, Hausdorff JM (2011) An instrumented timed up and go: the added value of an accelerometer for identifying fall risk in idiopathic fallers. Physiol Measure 32(12):2003

    Google Scholar 

  • Whitney SL, Poole JL, Cass SP (1998) A review of balance instruments for older adults. Am J Occup Ther 52(8):666–671

    Article  Google Scholar 

  • Zampieri C, Salarian A, Carlson-Kuhta P, Aminian K, Nutt JG, Horak FB (2010) The instrumented timed up and go test: potential outcome measure for disease modifying therapies in Parkinson’s disease. J Neurol Neurosurg Psychiatry 81(2):171–176

    Article  Google Scholar 

  • Zampieri C, Salarian A, Carlson-Kuhta P, Nutt JG, Horak FB (2010) Assessing mobility at home in people with early Parkinson’s disease using an instrumented timed up and go test. Parkinson Relat Disord

Download references

Acknowledgments

Partially funded by the German Ministry of Eduction and Research within the research project PAGE (01FCO8044).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Thomas Frenken.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Frenken, T., Brell, M., Gövercin, M. et al. aTUG: technical apparatus for gait and balance analysis within component-based Timed Up & Go using mutual ambient sensors. J Ambient Intell Human Comput 4, 759–778 (2013). https://doi.org/10.1007/s12652-012-0151-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12652-012-0151-x

Keywords

Navigation