Models for low resolution slit scan measurements based on high resolution laser scanning image analysis: DNA and nuclear dimensions

https://doi.org/10.1016/0031-3203(81)90031-5Get rights and content

Abstract

A laser scanning microscope has been developed and employed to make high precision measurements of cells from clinical cervical samples. These specimens have been stained with the DNA specific fluorochrome mithramycin and the fluorescent images analyzed to give information on nuclear size, DNA content and nuclear shape. This information has been used to develop low resolution parameters as measured with flow cytometers, thus permitting some comparisons between high resolution and low resolution features as measured from the same cells. The results indicate that both low resolution flow slit scan and high resolution pattern recognition techniques yield the same average cellular information. However, low resolution methods are insensitive to shape and the influence of shape on the broadening of low resolution features is now under investigation.

References (28)

  • M. Achatz, R. Beck, G. Seger and G. von Sengbusch, Laser scanning technology for picture analysis of cells, Acta...
  • D. L. Barrett, E. B. King, R. H. Jensen and J. T. Merrill, Cytomorphology of gynecological specimens analyzed and...
  • L. S. Cram, Los Alamos Scientific Laboratory, private communication...
  • H.A. Crissman et al.

    Rapid staining methods for analysis of DNA and protein in mammalian cells

    J. Histochem. Cytochem.

    (1976)
  • H.A. Crissman et al.

    Cell cycle analysis in 20 minutes

    Science

    (1974)
  • W. Gohde et al.

    Technique of impulse cytophotometry of cervical and vaginal smears

  • W. Hartel et al.

    Signal analysis of slit scan contour data

    J. Histochem. Cytochem.

    (1979)
  • J. Holmquist et al.

    Computer Analysis of cervical cells

  • V. Kachel et al.

    Uniform lateral orientation, caused by flow forces of flat particles in flow-through systems

    J. Histochem. Cytochem.

    (1977)
  • D.B. Kay et al.

    Laser stroboscopic photography: technique for cell orientation

    Studies in Flow.

    (1977)
  • D.B. Kay et al.

    Imaging system for correlating fluorescence cell measurements in flow

    SPIE

    (1977)
  • J. Leveinson et al.

    Improved acriflavine feulgen reagent for wuantitative DNA cytofluorometry

    J. Histochem. Cytochem.

    (1978)
  • R. Mann, P. F. Mullaney and M. Achatz, Computer method for extraction of global features from fluorescent cell images...
  • T.K. Sharpless et al.

    Estimation of cell size from pulse shape in flow cytophotometry

    J. Histochem. Cytochem.

    (1976)
  • Cited by (4)

    • Scanning optical microscopy

      2020, Advances in Imaging and Electron Physics
      Citation Excerpt :

      Combining with image storage reduces the specimen irradiation to an absolute minimum. Scanning fluorescence microscopes have been reported by Mellors and Silver (1951), Loeser and West (1962), Slomba, Wasserman, Kaufman, and Nester (1972), and Mullaney et al. (1981). A point-source fluorescent microscope has the spatial frequency bandwidth of a conventional incoherent microscope operating at the primary wavelength.

    • Laser scanning fluorescence microscope

      1988, Proceedings of SPIE - The International Society for Optical Engineering
    • Scanning optical fluorescence microscopy

      1984, Journal of Microscopy
    • Laser Scanning Microscopy

      1982, Proceedings of the IEEE

    This work performed at Battelle Institute while P. Mullaney was on sabbatical from LASL.

    Present address: Biology Division, Oak Ridge National Laboratory, Box Y, Oak Ridge, TN 37830, U.S.A.

    View full text