Skip to main content
Log in

Maximum Entropy Reconstruction Methods in Electron Paramagnetic Resonance Imaging

  • Published:
Annals of Operations Research Aims and scope Submit manuscript

Abstract

Electron Paramagnetic Resonance (EPR) is a spectroscopic technique that detects and characterizes molecules with unpaired electrons (i.e., free radicals). Unlike the closely related nuclear magnetic resonance (NMR) spectroscopy, EPR is still under development as an imaging modality. Athough a number of physical factors have hindered its development, EPR's potential is quite promising in a number of important application areas, including in vivo oximetry. EPR images are generally reconstructed using a tomographic imaging technique, of which filtered backprojection (FBP) is the most commonly used. We apply two iterative methods for maximum-entropy image reconstruction in EPR. The first is the multiplicative algebraic reconstruction technique (MART), a well-known row-action method. We propose a second method, known as LSEnt (least-squares entropy), that maximizes entropy and performs regularization by maintaining a desired distance from the measurements. LSEnt is in part motivated by the barrier method of interior-point programming. We present studies in which images of two physical phantoms, reconstructed using FBP, MART, and LSEnt, are compared. The images reconstructed using MART and LSEnt have lower variance, better contrast recovery, subjectively better resolution, and reduced streaking artifact than those reconstructed using FBP. These results suggest that maximum-entropy reconstruction methods (particularly the more flexible LSEnt) may be critical in overcoming some of the physical challenges of EPR imaging.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. M. Afeworki, G.M. van Dam, N. Devasahayam, R.Murugesan, J. Cook, D. Coffin, J.H.A. Larsen, J.B. Mitchell, S. Subramanian and M. Krishna, Three-dimensional whole body imaging of spin probes in mice by time-domain radiofrequency electron paramagnetic resonance, Mag. Reson. Med. 43 (2000) 375–382.

    Google Scholar 

  2. L.J. Berliner, The scope of in vivo EPR, in: EPR Imaging and In Vivo EPR, eds. G.R. Eaton, S.S. Eaton and K. Ohno (CRC Press, Boca Raton, FL, 1991) pp. 10–12.

    Google Scholar 

  3. Y. Censor and S. Zenios, Parallel Optimization: Theory, Algorithms, and Applications (Oxford Press, 1997).

  4. G. Demoment, Image reconstruction and restoration: overview of common estimation structures and problems, IEEE Trans. Acoust., Speech, Signal Process. 37 (1989) 2024–2036.

    Google Scholar 

  5. N. Devasahayam, S. Subramanian, R. Murugesan, J.A. Cook, M. Afeworki, R.G. Tschudin, J.B. Mitchell and M.C. Krishna, Parallel coil resonators for time-domain radiofrequency electron paramagnetic imaging of biological objects, J. Magn. Reson. 142 (2000) 168–176.

    Google Scholar 

  6. A.V. Fiacco and G.P. McCormick, Nonlinear Programming: Sequential Unconstrained Minimization Techniques (Wiley, 1968). Republished, Society for Industrial and Applied Mathematics (SIAM), 1990.

  7. R. Gordon, R. Bender and G.T. Herman, Algebraic reconstruction techniques (ART) for threedimensional electron microscopy and X-ray photography, J. Theoretical Biology 29 (1970) 471–481.

    Google Scholar 

  8. S. Gull and J. Skilling, Maximum entropy method in image processing, Proc. of IEEE, Special Issue on Digital Signal Processors 131F-6 (1984) 646–659.

    Google Scholar 

  9. H.J. Halpern,M. Peric, C. Yu and B.L. Bales, Rapid quantitation of parameters from inhomogeneously broadened EPR spectra, J. Magn. Reson. Ser. A 103 (1993) 13–22.

    Google Scholar 

  10. H.J. Halpern, M. Peric, C. Yu, E.D. Barth, G.V.R. Chanramouli, Ma.W. Makimen and G.M. Rosen, In vivo spin-label murine pharmacodynamics using low-frequency electron paramagnetic resonance imaging, Biophys. J. 71 (1996) 403–409.

    Google Scholar 

  11. G.T. Herman and L. Meyer, Algebraic reconstruction techniques can be made computationally efficient, IEEE Trans. Med. Imag. 12 (1993) 600–609.

    Google Scholar 

  12. I.-T. Hsiao, A. Rangarajan, Y. Xing and G. Gindi, A smoothing prior with embedded positivity constraint for tomographic reconstruction, available via WWW at URL: http://cfi.lbl.gov/3D-2001/3D_Prog.html (2001).

  13. C.A. Johnson, Y. Yan, R.E. Carson, R.L. Martino and M.E. Daube-Witherspoon, A system for the 3D reconstruction of retracted-septa PET data using the EM algorithm, IEEE Trans. Nucl. Sci. 42 (1995) 1223–1227.

    Google Scholar 

  14. C.A. Johnson, J. Seidel, R.E. Carson, W.R. Gandler, A. Sofer, M.V. Green and M.E. Daube-Witherspoon, Evaluation of 3D reconstruction algorithms for a small animal PET camera, IEEE Trans. Nucl. Sci. 44 (1997) 1303–1308.

    Google Scholar 

  15. C.A. Johnson, J. Seidel and A. Sofer, Interior-point methodology for 3-D PET reconstruction, IEEE Trans. Med. Imag.19 (2000) 271–285.

    Google Scholar 

  16. L. Kaufman, Maximum likelihood, least squares and penalized least squares for PET, IEEE Trans. Med. Imag. 12 (1993) 200–214.

    Google Scholar 

  17. P.E. Kinahan, J.A. Fessler and J.S. Karp, Statistical image reconstruction methods in PET with compensation for missing data, in: Proceedings of the 1996 IEEE Nuclear Science Symposium and Medical Imaging Conference (IEEE Press, 1997) pp. 1486–1490.

  18. D.S. Lalush and B.M.W. Tsui, A fast and stable maximum a posteriori conjugate gradient reconstruction algorithm, Med. Phys. 22 (1995), 1273–1284.

    Google Scholar 

  19. D. Lalush, E.C. Frey and B.M.W. Tsui, Fast maximum entropy approximation in SPECT using the RBI-MAP algorithm, IEEE Trans. Med. Imag. 19 (2000) 286–294.

    Google Scholar 

  20. A. Lent, Maximum entropy and multiplicative ART, Image Analysis and Evaluation, in: Proc. of SPSE Conference, ed. R. Shaw, 1976, 249–257.

  21. M.M. Maltempo, S.E. Eaton and G.R. Eaton, Algorithms for spectral-spatial imaging with a “missing angle”, in: EPR Imaging and In Vivo EPR, eds. G.R. Eaton, S.S. Eaton and K. Ohno (CRC Press, Boca Raton, FL, 1991) 145–152.

    Google Scholar 

  22. D.P. McGarry, J. Cook, S. Subramanian, N. Devasahayam, M.K. Cherukuri and C.A. Johnson, Reconstruction of electron paramagnetic resonance images using iterative methods, in: Proceedings of the SPIE Symposium on Medical Imaging, Image Processing, Vol. 4322–1, 2001, pp. 24–29.

    Google Scholar 

  23. R. Murugesan, M. Afeworki, J.A. Cook, N. Devasahayam, R. Tschudin, J.B. Mitchell, S. Subramanian and M.C. Krishna, A broadband pulsed radio frequency electron paramagnetic resonance spectrometer for biological applications, Rev. Sci. Instrum. 69 (1998) 1869–1876.

    Google Scholar 

  24. R. Murugesan, J.A. Cook, N. Devasahayam, M. Afeworki, S. Subramanian, R. Tschudin, J.A. Larsen, J.B. Mitchell, A. Russo and M.C. Krishna, In vivo imaging of a stable paramagnetic probe by pulsedradiofrequency electron paramagnetic resonance spectroscopy, Mag. Reson. Med. 38 (1997) 409–414.

    Google Scholar 

  25. S.G. Nash and A. Sofer, Assessing a search direction within a truncated-Newton method, Oper Res. Let. 9 (1990) 219–221.

    Google Scholar 

  26. S.G. Nash and A. Sofer, A barrier method for large-scale constrained optimization, ORSA J. Computing 5 (1993) 40–52.

    Google Scholar 

  27. S.G. Nash and A. Sofer, A general-purpose parallel algorithm for unconstrained optimization, SIAM J. Optim. 4 (1991), 530–547.

    Google Scholar 

  28. S.G. Nash and A. Sofer, Linear and Nonlinear Programming (McGraw-Hill, New York, 1996).

    Google Scholar 

  29. K. Roth, NMR-Tomography and-Spectroscopy in Medicine, An Introduction (Springer, Berlin, 1984).

    Google Scholar 

  30. L.A. Shepp and B.F. Logan, The Fourier reconstruction of a head section, IEEE Trans. Nucl. Sci. 21 (1974), 21–26.

    Google Scholar 

  31. J. Skilling and R. Bryan, Maximum entropy image reconstruction: general algorithm, Mon. Not. R. Astr. Soc. 211 (1984) 111–124.

    Google Scholar 

  32. H.M. Swartz and J.F. Glockner, Measurement of oxygen by EPRI and EPRS, in: EPR Imaging and In Vivo EPR, eds. G.R. Eaton, S.S. Eaton and K. Ohno (CRC Press, Boca Raton, FL, 1991) pp. 261–290.

    Google Scholar 

  33. J.A. Weil, J.R. Bolton and J.E. Wertz, Electron Paramagnetic Resonance, Elementary Theory and Practical Applications (Wiley, New York, 1994).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Johnson, C.A., McGarry, D., Cook, J.A. et al. Maximum Entropy Reconstruction Methods in Electron Paramagnetic Resonance Imaging. Annals of Operations Research 119, 101–118 (2003). https://doi.org/10.1023/A:1022978322046

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1022978322046

Navigation