For Full-Text PDF, please login, if you are a member of IEICE,
or go to Pay Per View on menu list, if you are a nonmember of IEICE.
|
A Second Order Mixed-Mode Charge Pump Scheme for Low Phase/Duty Error and Low Power Consumption
Kyu-hyoun KIM In-Young CHUNG
Publication
IEICE TRANSACTIONS on Electronics
Vol.E90-C
No.1
pp.208-211 Publication Date: 2007/01/01 Online ISSN: 1745-1353
DOI: 10.1093/ietele/e90-c.1.208 Print ISSN: 0916-8516 Type of Manuscript: LETTER Category: Integrated Electronics Keyword: second order, charge pump, phase error, DLL, duty cycle corrector (DCC),
Full Text: PDF(193.7KB)>>
Summary:
A second order charge pump (SOCP) scheme is proposed in this letter. Compared with the conventional single charge pump, the second order charge pump does not suffer phase errors caused by the output voltage dependent current mismatches. Also, the second order charge pump can be implemented in a mixed-mode type, enabling the fast lock and the various operation modes simultaneously. The proposed SOCP has been adopted into the duty cycle corrector (DCC) loops of DDR2 DRAM, and shows a much widened correction range owing to the removal of the parasitic effects.
|
|
|