Abstract:
Preliminary results of an automatic system for single trial P300 visual evoked potential events detection are presented. For each single trial P300, several candidate eve...Show MoreMetadata
Abstract:
Preliminary results of an automatic system for single trial P300 visual evoked potential events detection are presented. For each single trial P300, several candidate events were generated, and then filtered, using 3 wave features. The surviving candidate events were fed into a SOM-based classifier. A context filter was applied before the final output. No stationary condition of the P300 is involved in the algorithms. Recordings of 27 assessment sessions, each with 120 trials, were visually inspected by experts to identify and mark the P300 events, which was accomplished in about one third of the trials. The dataset was divided in training (18) and testing (9) subsets. The system identifies the initial and end times of the P300; it obtained a sensitivity of 53.9%, a specificity of 64.0% and an accuracy of 61.2% in the testing dataset.
Published in: 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Date of Conference: 26-30 August 2014
Date Added to IEEE Xplore: 06 November 2014
Electronic ISBN:978-1-4244-7929-0
ISSN Information:
PubMed ID: 25570819